|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenance
|
|
Violation:
The records did not indicate the chlorine concentration and contact time used for disinfecting the potable water storage tanks after maintenance was completed. Also, the records did not indicate the free residual chlorine was less than or equal to 5.0 ppm before the potable water storage tanks were put back into service.
|
|
Recommendation:
Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service.
Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Port Main Line
|
|
Violation:
There was a seam at the bulkhead/deck juncture next to fire screen door deck 9.3.12.
|
|
Recommendation:
Seal the seam.
|
|
|
Item No.:
34
|
|
Site:
Buffet-Port Main Line
|
|
Violation:
The water from the handwash station drain line pooled on the deck due to the amount of water entering the deck drain.
|
|
Recommendation:
Install coaming around the deck drain or otherwise prevent the water pooling on the deck.
|
|
|
Item No.:
39
|
|
Site:
Galley-Garde Manger
|
|
Violation:
There was one live fruit fly in this area. The area was not in use at the time of the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
33
|
|
Site:
Galley-Garde Manger
|
|
Violation:
The deck drains below undercounter refrigerators 4811.011.104 and 4811.011.105 were soiled with plastic gloves and food debris. The area was not in use at the time of the inspection.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
24
|
|
Site:
Galley-Club Restaurant
|
|
Violation:
A bucket of sanitizing solution was measured at less than 50 ppm chlorine. The area was not in use at the time of the inspection.
|
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
34
|
|
Site:
Galley-Club Restaurant
|
|
Violation:
The cooling valve of the steam line for the hood-type dishwash machine was leaking, resulting in water pooling on the deck. Previously cleaned and sanitized items were stored approximately 38 centimeters (15 inches) above the deck. During the inspection, staff corrected the leak by replacing the gasket for the cooling valve.
|
|
Recommendation:
Ensure the plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
28
|
|
Site:
Galley-Club Restaurant
|
|
Violation:
Water was pooling on the deck near the clean storage rack. Previously cleaned and sanitized items were stored approximately 38 centimeters (15 inches) above the deck. These items were moved to the preparation counter.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
37
|
|
Site:
Galley-
|
|
Violation:
When the doors of the in-use combination ovens opened, excess condensation formed on the deckhead and bulkhead. Condensation was observed dripping onto the deck in front of the ovens and on the preparation table between the ovens. No food or clean items were impacted.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
There was one live fruit fly at the back of the service line and one live fruit fly on the outside of the ice/water machine. The area was setting up for the lunch service at the time of the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
Inside the in-use flight-type conveyor dishwash machine, the second to the right upper final rinse sanitizing spray nozzle was clogged, resulting in an ineffective spray pattern. Staff cleaned out the nozzle. The spray pattern was corrected.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Staff Mess
|
|
Violation:
There were at least five live fruit flies near the juice machine. The area was not in use at the time of the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
30
|
|
Site:
Buffet-Male Crew Public Toilet Room
|
|
Violation:
The toilet room was not equipped with single-serve paper towels. This toilet room was used by crew members working in the nearby food areas.
|
|
Recommendation:
Ensure each handwashing facility has a supply of hand-cleansing soap or detergent and a supply of single-service paper towels available.
|
|
|
Item No.:
19
|
|
Site:
Bar-Lobby Bar
|
|
Violation:
There was a cart with plates near the entrance to the bar. It appeared these were for passenger self-service. The plates were not inverted or covered. Staff stated they handle these items.
|
|
Recommendation:
During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
|
|
|
Item No.:
30
|
|
Site:
Bar-Lobby Bar
|
|
Violation:
There was no waste receptacle for the handwash station. The receptacle was replaced.
|
|
Recommendation:
Ensure a handwashing facility includes a sink, soap dispenser, single-use towels dispenser, and waste receptacle.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Dionisio Bar
|
|
Violation:
The light intensity was below 110 lux behind and to the left of the ice machine.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Air Handling Units
|
|
Violation:
Technical water was used to clean the distribution system.
|
|
Recommendation:
Use only potable water for cleaning HVAC distribution systems.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The cross-connection control program for atmospheric vacuum breakers did not include a description for the plumbing system component for each device installed. The log only included the device model and a general description of the location. Also, the log did not include the air gaps for the mineralizer backwash drain lines or the air gap for technical water filling in the laundry room. In addition, there were no dates showing that the air gaps were periodically inspected.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections. Inspect backflow prevention devices periodically and replace any failed units.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Laundry Room
|
|
Violation:
The air gap for the technical water filling station was not at least twice the diameter of the potable water supply line.
|
|
Recommendation:
Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunker Station Identification
|
|
Violation:
The 'potable water filling' identification at both bunker stations was not clearly labeled with letters at least 13 millimeters high.
|
|
Recommendation:
Ensure each bunker station potable water filling line is striped or painted blue or in accordance with the color designation in ISO 14726 (blue/green/blue) and clearly labeled "POTABLE WATER FILLING" in letters at least 13 millimeters (0.5 inch) high, stamped on a noncorrosive label plate or the equivalent, and located at or near the point of the hose connection.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Aft Swimming Pool/Water Slide
|
|
Violation:
The water slide was not correctly identified as an activity pool and was not being halogenated consistently to at least 2.0 ppm free residual chlorine. The aft swimming pool and the water slide shared the same compensation tank and chlorine dosing, but the water slide did not empty directly into the swimming pool. The electronic data logger records for the aft swimming pool indicated that the free residual chlorine was below 2.0 ppm for several hours each day during operating hours over the last few months. The records also indicated that the pool was consistently opened with free residual chlorine levels below the required 2.0 ppm. When tested during the inspection, the free residual chlorine level in the water slide was measured at greater than 2.0 ppm.
|
|
Recommendation:
During operations, ensure interactive recreational water facilities, to include activity pools (wave pools, catch pools, water slides, lazy rivers, action rivers, vortex pools, continuous surface pools, etc.) maintain a free residual halogen level of at least 2.0 ppm and less than or equal to 5.0 ppm.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Water Slide Monitoring
|
|
Violation:
There was no automated free residual chlorine and pH monitoring for the water slide. The water slide and aft swimming pool shared the same compensation tank and chlorine dosing, but the water slide did not empty directly into the swimming pool.
|
|
Recommendation:
Install automated systems for halogen-based disinfection and pH control dosing. Control the amounts injected by flow meters or free halogen and pH analyzers.
|
|