Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 02/16/2013 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 11
Site: Medical-Crew Acute Gastroenteritis (AGE) Reporting
Violation: The review of the AGE logs for the last 5 cruises revealed that there was a resident pianist who experienced AGE symptoms and continued to work after those symptoms began. Specifically, he reported an onset of symptoms on 6 January at 8:00 am but reported to the medical center at 10:00 pm that day. His time card documented that he worked 5:46 - 7:40 pm and 8:33 pm - 10:40 pm. He also reported going to the officer's mess for breakfast, lunch, and dinner while sick and before reporting to the medical center. The staff stated that this person clocked out of work after going to the medical center.
Recommendation: Ensure that employees having AGE symptoms are restricted from work and report to the medical center as soon as having their first AGE symptom.
Item No.: 03
Site: Potable Water-Bunkering
Violation: The pH levels during active potable water bunkering were not stabilized and the levels were measured manually at above 8.40 twice and 7.6 once by the staff and the inspector. These levels were not controlled after more than 2 hours of the start of bunkering and the station was unattended. The staff adjusted the acid pump and pH levels appeared to start to stabilize according to the readings of the automated analyzer.
Recommendation: Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
Item No.: 41
Site: Other-Engine Changing Room
Violation: The toilet room in the engine changing room did not have a method to dry hands or signs advising users to wash hands or signs advising users to use hand towels, paper towel, or tissue to open the door when exiting. There was a roll of toilet tissue in the changing room and not inside the toilet room. There was a large bag of trash on the deck of the toilet room.
Recommendation: Provide the passenger and crew public toilets with a handwashing station that includes a method to dry hands and a sign advising users to wash hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
Item No.: 08
Site: Potable Water-
Violation: The drain line for the sampling point at the bunker station was inside a funnel and the funnel was full of water due to a clogged pipe. The clogged pipe lead to the bilge.
Recommendation: Provide an air gap for the drain line for the sampling point.
Item No.: 10
Site: Recreational Water Facilities-Filter Housings
Violation: The previous inspection conducted in August 2012 revealed that there was no documentation for filter housing cleaning and disinfection. This inspection revealed that the staff implemented a record documenting that filter housings on the RWFs were cleaned and disinfected as often as required, but only stated that they were 'Done' and there was no documentation regarding the disinfectant concentration or contact time.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Water Chemistry
Violation: The previous inspection conducted in August 2012 revealed that no monitoring of combined chlorine levels and total alkalinity were conducted because the test kit at the time could not test for these parameters. This inspection revealed that the staff was not monitoring combined chlorine levels and total alkalinity even when a test kit capable of measuring these water parameters was available.
Recommendation: Monitor and adjust the RWF's flow rates, free and combined halogen levels, pH, total alkalinity, and clarity as recommended by the manufacturer and to maintain optimum public health protection and water chemistry.
Item No.: 10
Site: Recreational Water Facilities-Shepherd?s Hook
Violation: The rescue or shepherd's hook was stored under the port bench area at the beach deck and not provided at a prominent location visible from the full perimeter of the pool.
Recommendation: Provide a rescue or shepherd's hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency.
Item No.: 10
Site: Recreational Water Facilities-Turnover Rates & Bather Loads
Violation: The previous inspection conducted in August 2012 revealed that turnover rates and bather loads were not calculated because no flow meters were installed. This inspection revealed that flow meters were installed after that inspection finding, but still turnover rates and bather loads for the RWFs were not calculated.
Recommendation: For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (5) whirlpool spa: 0.5 hours. Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow.
Item No.: 10
Site: Recreational Water Facilities-Safety Signs
Violation: The safety signs had a bather load of 18 persons for the pool and 8 persons for each whirlpool. The staff did not know where these numbers came from since they had not calculated the bather loads.
Recommendation: Post bather loads resulting from calculations made per section 6.2.1.5.
Item No.: 36
Site: Galley-Prime 7 Pantry
Violation: The light intensity was less than 220 lux on the two food preparation counters.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Buffet-La Veranda
Violation: The light intensity was less than 220 lux along the service side of the buffet. Also, the light intensity was less than 220 lux at the handwash station near the toaster.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Galley-La Veranda
Violation: The light intensity was less than 110 lux behind the glasswash machine. Staff showed an e-mail indicating an extension until April 2013 for lighting upgrades.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Preparation Room-
Violation: The light intensity was less than 220 lux at the handwash station.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 20
Site: Preparation Room-
Violation: There were slotted fasteners in the food splash zone of the potato peeler. This equipment was out of service on the day of the inspection.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones.
Item No.: 26
Site: Preparation Room-
Violation: The inside of the shaft of the previously cleaned vegetable slicer was soiled with food residue.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 19
Site: Preparation Room-
Violation: Two lexan boxes of whole lettuce were stored on a deck stand near the vegetable slicer and one box was on the preparation counter. These boxes were uncovered and no one was in the area at the time of the inspection.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected.
Item No.: 20
Site: Galley-Deck 5
Violation: Inside the top compartment of ice machine #2, the white plastic panel to the back side of the stainless steel front cover was warped and in poor condition, exposing glue residue.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
Item No.: 11
Site: Galley-Ice Machines
Violation: A refrigeration engineer had 3 to 5 stitches on his right thumb and was opening ice machines with his wound uncovered.
Recommendation: Ensure food employees who have conditions or symptoms of boils, open sores, infected wounds, diarrhea, jaundice, fever, vomiting, sore throat with fever, or discharges from the nose or mouth report these conditions or symptoms to the vessel's medical staff and are restricted from working with exposed food, warewashing, clean equipment, utensils, and linens, and unwrapped single-service and single-use articles.
Item No.: 22
Site: Galley-Dishwash
Violation: The final rinse gauge of the in-use flight-type conveyor dishwasher measured temperatures between 193°F and 210°F. The manufacturer's data plate required temperatures between 180°F and 195°F for the fresh hot water sanitizing rinse as it entered the manifold. The final rinse temperature was acceptable at the plate level. The gauge was repaired during the inspection.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 39
Site: Galley-
Violation: There was one large fly on the bulkhead at the handwash station near the tray storage rack.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 20
Site: Galley-Pastry/Bakery
Violation: There were slotted fasteners in the food contact area of the two deck ovens.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones.
Item No.: 19
Site: Bar-Stars Lounge
Violation: The counter ice bin was full and uncovered. The area was unattended at the time of the inspection.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected.
Item No.: 16
Site: Bar-Galileo's
Violation: Staff stated that food items such as ham and cheese sandwiches were served during afternoon tea time and time was used as public health control. However there was no time control plan available for this service.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 36
Site: Bar-Casino Bar
Violation: The light intensity was less than 110 lux at the handwash station during operations. Staff showed an e-mail indicating an extension until April 2013 for lighting upgrades.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars.
Item No.: 16
Site: Bar-Navigator Lounge
Violation: Containers of milk were identified as being on time control and had their set-up and discard times affixed to them. However, these times did not match what was on the time control plan. This was noted on the previous inspection. Also, the undercounter refrigerator where these containers were stored was not labeled as being on time control.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 21
Site: Galley-
Violation: The back side of the turning handles for the tilting kettles had peeling soft sealant, making cleaning difficult.
Recommendation: Replace the sealant.
Item No.: 22
Site: Galley-Warewash
Violation: The upper final rinse spray nozzles of the rack-type warewash machine did not completely cover across the racks coming through the machine. It was determined that some of the nozzles were turned and sprayed along the length of the machine. Each spray nozzle was repositioned forming effective spray patterns.
Recommendation: Ensure that all final sanitizing spray nozzles of the upper spray arm form effective spray patterns.
Item No.: 10
Site: Recreational Water Facilities-Antientrapment/Antientanglement Requirements
Violation: The previous inspection conducted in August 2012 revealed that none of the two whirlpools or pool was compliant with the antientrapment/antientanglement requirements. Progress was done but still the port whirlpool was not compliant. It had multiple gravity drains and suction fittings less than three feet apart and no antientrapment drain covers or secondary antientrapment protection. The staff stated that compliant drain covers were onboard but not yet installed.
Recommendation: For RWFs with gravity drainage and a single blockable drain or multiple drains less than 3 feet apart, provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a gravity drainage system. For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program