Item No.:
02
|
|
Site:
Medical-Acute Gastroenterititis (AGE) Log
|
|
Violation:
The ship was using the correct VSP 2011 log form until voyage starting 14 SEPT 2012 when a company supplied form (MEDLOG 3) was substituted. This incorrect form does not provide the following order and content to the record: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person's name; (5) person's age; (6) person's sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person's name; (5) person's age; (6) person's sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Time Control Plans
|
|
Violation:
The posted time control plans in the various galleys, crew and officers messes did not list bain marie's or cold basins as being on time control. The La Terrazza and Pool Grill plans did not identify cold basins as being on time control. In all plans except the main galley garde' manger the potentially hazardous foods set on counters were not identified in the posted plans as being on time control. One reach-in refrigerator in La Terrazza was listed as time control but was not labeled with the words time control.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
16
|
|
Site:
Galley-Main Galley - Hot Galley
|
|
Violation:
The potentially hazardous foods in open containers on the counters for the omelet station were labeled with the words 4 hours, rather than with the actual discard time for those foods.
|
|
Recommendation:
Mark each container of food with the discard time.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley - Pastry/Bakery
|
|
Violation:
The dough sheeter belt was heavily worn and torn in sections. Staff stated a new belt was on order.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Beverage Station
|
|
Violation:
The espresso machine was set on legs only 25 mm above the counter and the surface below was visibly soiled with dust debris. Staff corrected this during the inspection.
|
|
Recommendation:
Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
|
|
|
Item No.:
21
|
|
Site:
Buffet-La Terrazza Buffet
|
|
Violation:
Power cables were coiled on the counter below the beverage dispensers. This was corrected during the inspection.
|
|
Recommendation:
Shorten cables or elevate them so the counter below remains easy to access and clean.
|
|
|
Item No.:
21
|
|
Site:
Bar-Panorama Bar
|
|
Violation:
The espresso machine was mounted only 25mm above the counter. Staff corrected this during the inspection.
|
|
Recommendation:
Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Beverage Station
|
|
Violation:
Power cables to the toaster oven and beverage dispensers was draped on the counter below the machines, making the counter difficult to clean. These were corrected during the inspection.
|
|
Recommendation:
Shorten cables or elevate them so the counter below remains easy to access and clean.
|
|
|
Item No.:
21
|
|
Site:
Housekeeping-Deck 6 Ice Pantry
|
|
Violation:
Neutral cabinet shelf at entry had difficult to clean frayed duct tape used on the front edge of several shelves where wrapped room service food trays were stored.
|
|
Recommendation:
Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
|
|
|
Item No.:
22
|
|
Site:
Galley-Main Galley - Pot Wash
|
|
Violation:
The in-use pot wash machine had a broken wash temperature gauge and wash pressure gauge.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
The in-use stationary rack dishwash machine displayed a final hot water sanitizing rinse pressure of only 10 psi. The manufacturer specifies a minimum 15 psi pressure.
|
|
Recommendation:
Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine's data plate and other manufacturer's instructions. Ensure a warewashing machine's conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer's specifications.
|
|
|
Item No.:
24
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
The in-use conveyor dishwash machine was registering a final hot water sanitizing rinse temperature of only 120 °F on the mounted final rinse gauge. The dish level temperature was also registering 120 °F. Staff repaired the machine during the inspection.
|
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
|
|
|
Item No.:
24
|
|
Site:
Galley-Main Galley - Pot Wash
|
|
Violation:
During manual sanitizing in the 3rd sink the employee was observed holding some pans in the water for only 5 seconds prior to removal for storage on the clean rack.
|
|
Recommendation:
Ensure a chemical sanitizer is used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
|
|
|
Item No.:
27
|
|
Site:
Galley-Beverage Station
|
|
Violation:
The counter beneath the espresso machine was visibly soiled with dust debris. Staff corrected this during the inspection.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
30
|
|
Site:
Other-Pool Grill
|
|
Violation:
There was no paper towel dispenser at the handwash station in the grill service area. Additionally, the handwash station did not have a sign stating 'Wash Hands Often'.
|
|
Recommendation:
Ensure a handwashing facility includes a sink, soap dispenser, single-use towels dispenser, and waste receptacle. Post a sign over handwashing sinks stating "WASH HANDS OFTEN" in a language that the food employees understand.
|
|
|
Item No.:
33
|
|
Site:
Other-Pool Grill
|
|
Violation:
The deck was not coved at the juncture with the buffet on the passenger side.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
36
|
|
Site:
Housekeeping-Deck 6 Ice Pantry
|
|
Violation:
Light level behind and around the ice machine was not 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
The artificial light level behind the conveyor dishwash machine was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Artificial Lighting
|
|
Violation:
Artificial light levels were below the minimum 110 lux behind ice machines and beverage station equipment in galleys and most other food areas. This was also noted beside the stack oven in the main galley pastry, behind the Franke steam oven in the crew galley, and in the forward starboard corner of the provisions dry store room. This was also noted in the previous VSP inspection report.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
39
|
|
Site:
Galley-Crew Galley - Hot Galley
|
|
Violation:
One live fruit fly was observed on a seam between deckhead panels.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP specified an 'All Purpose Cleaner and Disinfectant' product be used for disinfection of surfaces. No measurable residual was specified for the disinfecting compound. Test strips were not available to verify the concentration.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses).
|
|