Cruise Ship: Island Princess Cruise Line: Princess Cruises Inspection Date: 06/18/2016 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Buffet-Horizon Court
Violation: Behind the port side buffet line and below the 'Metropolitan' window the surface of the bulkhead was chipped and rough, creating a difficult to clean surface.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 28
Site: Galley-Deck 12 Horizon Court Production
Violation: A mixer was placed next to the handwashing station, by the entrance, and below the paper towel dispenser, and water from handwashing splashed on the mixer.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (2) in a location where they are not exposed to splash, dust, or other contamination.
Item No.: 36
Site: Galley-Deck 12 Horizon Court Production
Violation: The light intensity was less than 110 lux in a corner of the blast chiller, and a light was not working.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 37
Site: Buffet-Crew Mess Line 1
Violation: Condensation was noted on the sneeze shield and the underside of the shelf above the food. Dripping was observed into the pans of hot foods.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 19
Site: Buffet-Crew Mess Line 1
Violation: Dripping was observed into some of the containers of hot foods and behind the food onto the counter.
Recommendation: Protect food from contamination by storing the food: 3) Where it is not exposed to splash, dust, or other contamination. Protect food from contamination that may result from a physical, chemical, biological origin.
Item No.: 26
Site: Buffet-Crew Mess Beverage Station
Violation: Black and white residue were noted around the upper gray supply tube in the undercounter ice bin of the ice dispenser.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 39
Site: Galley-Dishwash Area
Violation: One live fruit fly was observed behind the ice machine by the clean end of the dishwasher.
Recommendation: Effectively control the presence of insects to minimize their presence in the food areas aboard a vessel.
Item No.: 20
Site: Pantry-Officer Mess
Violation: Two slotted fasteners were observed on the food contact surfaces of the espresso machine.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 16
Site: Other-Trident Grill
Violation: Two hot dog warming pans with lids, used for time control and listed on the time control plan, were not labeled as time control units. This was corrected.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
Item No.: 24
Site: Other-Trident Grill
Violation: A bucket of sanitizing solution had a concentration less than 50 ppm.
Recommendation: Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 20
Site: Preparation Room-Deck 6 Pastry
Violation: The boiler had been out of order since February 2016. Spare parts had been ordered.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
Item No.: 39
Site: Preparation Room-Deck 6 Pastry
Violation: One live fruit fly was observed in this area.
Recommendation: Effectively control the presence of insects to minimize their presence in the food areas aboard a vessel.
Item No.: 16
Site: Galley-Deck 6 Pastry
Violation: The time control plan stated undercounter refrigerator #062341B was a time control unit, but this unit was not labeled time control.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
Item No.: 21
Site: Galley-Deck 6 Bakery
Violation: The fan guards inside the proofer cabinets were corroded.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 20
Site: Galley-Deck 5 Butcher
Violation: One of the four cutting boards was heavily scored.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices.
Item No.: 33
Site: Galley-Deck 5 Hot Section
Violation: The sprayer hoses for combination ovens 1 and 4 were lying on the deck.
Recommendation: Ensure decks maintained for easy cleaning.
Item No.: 20
Site: Preparation Room-Deck 4 Potato Room
Violation: Sealant around the gasket of the potato peeler doors was partially peeling, creating a difficult to clean surface.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices.
Item No.: 39
Site: Preparation Room-Deck 4 Potato Room
Violation: Two live fruit flies were observed in this area.
Recommendation: Effectively control the presence of insects to minimize their presence in the food areas aboard a vessel.
Item No.: 39
Site: Pantry-La Patisserie
Violation: One live fruit fly was observed by the soda multiflow cabinet.
Recommendation: Effectively control the presence of insects to minimize their presence in the food areas aboard a vessel.
Item No.: 20
Site: Pantry-La Patisserie
Violation: One slotted fastener was noted in the food surface area of the espresso machine.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 39
Site: Buffet-Horizon Court
Violation: One live fruit fly was observed behind the port side buffet line.
Recommendation: Effectively control the presence of insects to minimize their presence in the food areas aboard a vessel.
Item No.: 02
Site: Medical-Bacterial Clinical Specimen Containers
Violation: The ship did not have specimen collection containers specific for bacteria. The medical center had collection tubes with medium specific for virus specimens, and other neutral collection containers with no medium.
Recommendation: Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each).
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The list of backflow prevention devices was updated in May 2016. Entries for air gaps stated the location and plumbing component, but it was confusing of the exact plumbing component where the air gaps could be found in the food areas. For example: the list stated 'Location = Main Galley (deck 5, fire zone 3), Plumbing Component = Galley;' also 'Location = Crooner's Bar, Plumbing Component = Pantry.' Staff explained these air gaps were for the handwash station faucet taps.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location.Air gaps on faucet taps do not need to be included on the cross-connection control program list. If the ship chooses to keep these on the list, update the list to specify where the air gaps are located. Or delete from the list.
Item No.: 10
Site: Recreational Water Facilities-Shock Bromination
Violation: From 24 February - 3 March, the start and stop times and start and stop concentrations for shock bromination were not documented for five of the six whirlpool spas. This included the Lido (port), Lido (starboard 1 and 2), Lotus (port and starboard) whirlpool spas.
Recommendation: Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing. Ensure a written or electronic record of the date and time of water dumping and shock halogenation (concentration in ppm at the start and completion and time) is available for review during inspections.
Item No.: 44
Site: Buffet-Horizon Court
Violation: On the last inspection it was noted the Horizon Court buffet was extensively renovated during the May 2015 dry dock, but no passenger handwash stations were installed as per the 2011 VSP Construction Guidelines. Staff showed emails, dated February 2016, between VSP and public health corporate with plans to add handwash stations to the buffet lines. Staff did not know when the handwash stations would be installed.
Recommendation: The vessel/company should provide a timeline for the installation of passenger handwashing stations.