Cruise Ship: Azamara Quest Cruise Line: Azamara Cruises Inspection Date: 12/22/2017 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 01
Site: Medical-24-Hour Reports
Violation: The 24-hour reports submitted prior to arrival into the U.S. on two separate voyages listed the wrong embarkation port code. The 24-hour report submitted prior to arrival in St. Thomas, USVI, on 8 December listed the embarkation port code on 1 December as NUS (not inside the U.S.) instead of MIA for Miami, FL. The 24-hour report submitted prior to arrival in Miami, FL, on 1 December listed the embarkation port code on 27 November as NUS (not inside the U.S.) instead of MIA for Miami, FL.
Recommendation: Ensure the AGE report contains the following: (2) port of embarkation.
Item No.: 08
Site: Potable Water-Testable Devices
Violation: The reduced pressure backflow assemblies on the port and starboard international shore connections were tested on 4 December, but no pressure differential values from the test were recorded. In addition, no testing date or results for the reduced pressure backflow assembly on the hot water line to incinerator (Deck 2) and on the water line to the eco washing line engine room casing (Deck 8) were available.
Recommendation: Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
Item No.: 08
Site: Potable Water-Evaporator
Violation: Water was continuously leaking from the relief vent on the reduced pressure backflow assembly on the high saline overboard discharge, indicating a possible failure.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 08
Site: Potable Water-Production to Distilled Water Tanks
Violation: Water was continuously leaking from the relief vent on the reduced pressure backflow assembly on the transfer line from the evaporator to the boiler and distilled water tanks, indicating a possible failure.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Spas
Violation: The daily shock halogenation was not performed on the port and starboard whirlpool spas on 13 December. The timeframe between shock halogenation on 14 December (finished at 08:22) and on 15 December (finished at 20:11) was more than 24-hours.
Recommendation: Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
Item No.: 10
Site: Recreational Water Facilities-Main Pool
Violation: The floatation device for the pool did not have an attached rope.
Recommendation: Provide a rescue or shepherd's hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency. Ensure the approved flotation device includes an attached rope that is at least 2/3 of the maximum pool width.
Item No.: 21
Site: Pantry-Housekeeping Pantries
Violation: The clean stainless steel storage racks had strips of red, yellow, and green colored duct tape on the corner bar, which made the surface difficult to clean. Staff stated these markings were indicated the ergonomic risk for each shelf; with the injury risk from placing a rack on the storage shelf increasing from green to red. Although the inspector only observed this set-up in Deck 6 and Deck 8 Aft Housekeeping Pantries, staff stated that this arrangement was present in all the housekeeping pantries on the ship.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 29
Site: Galley-Mini Galley Pizza Station
Violation: A crew member was observed preparing sanitizing solution in the handwash sink.
Recommendation: Ensure handwashing facilities are used for no other purpose and are accessible at all times.
Item No.: 39
Site: Buffet-Bread and Pastry Station
Violation: One house fly was observed resting on a pastry.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 19
Site: Buffet-Bread and Pastry Station
Violation: One house fly was observed resting on a pastry.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 27
Site: Buffet-Bread and Pastry Station
Violation: Milk had pooled on a tray in an undercounter refrigerator. None of the cartons of milk stored in this area appeared to be leaking.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 30
Site: Galley-Male Toilet Room Outside Mini Galley
Violation: The male toilet room door was not self-closing. This was immediately corrected.
Recommendation: Ensure toilet rooms are completely enclosed and have tight-fitting, self-closing doors which are kept closed except during cleaning or maintenance.
Item No.: 30
Site: Galley-Aft Male Toilet Room
Violation: The male toilet room door was not self-closing.
Recommendation: Ensure toilet rooms are completely enclosed and have tight-fitting, self-closing doors which are kept closed except during cleaning or maintenance.
Item No.: 32
Site: Galley-Room Service
Violation: A yellow waste receptacle containing food waste was uncovered. The area was not in use at the time of the inspection.
Recommendation: Cover receptacles and waste-handling containers when not in continuous use and after they are filled.
Item No.: 39
Site: Galley-Room Service
Violation: One house fly was observed in this area. The area was not in use at the time of the inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Pastry
Violation: One house fly was observed on the ice cream machine. This area was in use during the inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Pastry
Violation: One fruit fly was observed near the deck ovens.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 34
Site: Galley-Hot Galley
Violation: Multiple hot water pipes under the hot service line were continuously dripping. As a result, water was pooling on the deck in this area.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 33
Site: Galley-Hot Galley
Violation: Multiple hot water pipes under the hot service line were continuously dripping. As a result, water was pooling on the deck in this area.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 22
Site: Galley-Potwash
Violation: Water from the hood-type potwash machine was continuously dripping onto the deck.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 35
Site: Galley-Potwash
Violation: Water from the hood-type pot machine was continuously dripping onto the deck. Water had pooled in this area.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 22
Site: Galley-Rack Type Dish Machine
Violation: The wash temperature gauge on the dishwash machine was not in working order. Crew reported the gauge out-of-order on 5 December.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Conveyor Belt Dish Machine
Violation: The metal bar under the conveyor belt was heavily soiled with a brown dust-like substance.
Recommendation: Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
Item No.: 22
Site: Galley-Conveyor Belt Dish Machine
Violation: Crew members had to keep adjusting the belt of the dish machine approximately every two to three minutes to keep the machine running. Staff stated the belt rollers needed to be replaced and that parts had been ordered.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 16
Site: Dining Room-Menus
Violation: There was no consumer advisory asterisk noted for the 5 oz. filet mignon on menu #12, the grilled lemon-garlic T-bone lamb chops on menu #10, and the grilled venison on menu #3. These food products can be cooked-to-order.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 33
Site: Galley-Deck 4 Near Stairs
Violation: Water was dripping from the deckhead on to the deck. It was unclear where the water was coming from.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Provisions-Vegetable
Violation: A very small amount of water dripped from the deckhead onto the side of a closed box of bagged spinach.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 28
Site: Buffet-Staff Mess
Violation: Two pitchers and two coffee dispensers were stored wet with their lids attached in a cabinet under the bread service line.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 19
Site: Provisions-Vegetable
Violation: A very small amount of water had dripped onto the side of a closed box of bagged spinach.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 19
Site: Provisions-Corridor
Violation: One banana tree leaf, which was intended to be used for decoration only, was sitting on top of a pallet of grapes. A box of grapes was sitting on top of the leaf.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 22
Site: Galley-Dish Wash
Violation: The final rinse gauge was not in working order at the time of the inspection. Staff stated the gauge quit working about a week prior.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Dish Wash
Violation: The curtain located between the rinse and final rinse compartments was heavily soiled with food debris.
Recommendation: Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
Item No.: 18
Site: Buffet-The Patio
Violation: Raw chicken wings were stored over raw ground beef patties in an undercounter refrigerator.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
Item No.: 38
Site: Galley-Cleaning Locker
Violation: Three buckets were not stored inverted in this area.
Recommendation: Ensure wash, rinse, and sanitize buckets or other containers stored with maintenance tools are inverted and nested.
Item No.: 30
Site: Galley-Deck 10 Specialty Restaurants Crew Toilet Room
Violation: The toilet was out-of-order and food preparation was occurring in the galley. Staff stated crew could use a toilet located below on deck 9.
Recommendation: Keep toilet fixtures clean and in good repair.
Item No.: 30
Site: Other-Deck 3 Toilet Room Outside Crew Mess
Violation: There was a large gap between the deck and the bottom of the toilet room door.
Recommendation: Ensure toilet rooms are completely enclosed and have tight-fitting, self-closing doors which are kept closed except during cleaning or maintenance.
Item No.: 33
Site: Galley-Potwash
Violation: The deck beneath the hood-type potwash machine was also soiled with brown debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.