Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Oceania Sirena Cruise Line: Oceania Cruises Inspection Date: 12/15/2017 Inspection Score: 85
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 03
Site: Potable Water-Production
Violation: The ship entered into the Amazon River on 16-Oct-17 and exited the Amazon river on 22-Oct-17 and produced water while sailing on the Amazon River on 16-Oct-17, 17-Oct-17, 18-Oct-17, 21-Oct-17, and 22-Oct-17. The ship's potable water production log showed the ship began producing water during the following time periods: 1) on 16-Oct-17 from 0900 until 1200; 2) on 17-Oct-17 from 0330 until 1045; 3) on 18-Oct-17 from 0100 until 0430; and 21-Oct-17 to 22-Oct-17 from 1410 until 0530. The ship's schedule identified the ship entered into the Amazon River at the Macapa clearance on 16-Oct-17; sailed to Santarem, BR on 17-Oct-17; sailed to Parintins, BR on 18-Oct-17; sailed to Manaus, BR on 19-Oct-17; sailed to Boca da Valeria, BR on 20-Oct-17; sailed to Alter Do Chao, BR on 21-Oct-17; and exited the Amazon River via the Macapa clearance on 22-Oct-17.
Recommendation: Operate a reverse osmosis unit, distillation plant, or other process that supplies water to the vessel's potable water system only while the vessel is making way, and do not operate in polluted areas, harbors, or at anchor.
Item No.: *
Site: Potable Water-Testable Devices Log
Violation: The list of testable backflow prevention devices included information on differential pressures recorded during tests conducted in May 2017, but the testing and documentation procedure could not be clarified by staff. Specifically, seventeen reduced pressure zone (RPZ) backflow prevention devices had initial and final pressure along with a subtraction value from these two pressure readings. Staff stated that the difference between these two pressures should not be above 0.5 PSI to pass the test; however, there was no documentation on the device manufacturer's instructors nor elsewhere indicating this kind of methodology to test these devices. Additionally, there was no documented differential pressure at the time the RPZ started to leak from the intermediate relief vents as required by the device manufacturer's four-step testing procedure. This is a repeat violation from the previous VSP inspection.
Recommendation: Ensure the RPZs are tested according to the manufacturer?s recommendations.
Item No.: 08
Site: Potable Water-Medical Facility Bathroom Facilities
Violation: The backflow prevention testing log, dated 30 Nov 2017, did not specifically identify the two vacuum breaker backflow prevention devices located on each of the shower hoses in the two bathrooms inside the ship's medical facility.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 10
Site: Recreational Water Facilities-Portside and Starboard Side Whirlpool Spas
Violation: On 9-Nov-17, the ship's portside and starboard side whirlpool spas were opened for service at 0600 and these recreational water facilities were not emptied until 12-Nov-17 at 2100 - a period of approximately 87 hours. Staff was unable to produce any documentation showing these facilities were closed once 72 hours passed without a change of water.
Recommendation: Change the whirlpool spa water, including compensation tank, filter housing, and associated piping, every 72 hours, provided that the system is operated continuously and that the correct water chemistry levels are maintained during that period, including daily shock halogenation. Change spa pool water as often as necessary to maintain proper water chemistry. Change the water at least every 30 days. Record the date and time of whirlpool spa and spa pool water changes in the log.
Item No.: 10
Site: Recreational Water Facilities-Bather Loads
Violation: The documentation of the bather load calculations was not available. Staff identified this document was not available on the ship and would reach out to corporate. This is repeat violation from the previous VSP inspection.
Recommendation: Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow.
Item No.: 26
Site: Buffet-Waves Grill
Violation: Four previously cleaned plates out for service on the employee side of the buffet line were soiled with food debris.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 19
Site: Buffet-Terrace Buffet Aft Service Line
Violation: Two separate storage cups of water that were used to hold the knives used to slice the cheese on the buffet line were on the port and starboard employee side of the buffet. The water in each cup was soiled and around 95°F when measured.
Recommendation: During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container; (2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon; (3) On a clean portion of the food preparation table or cooking equipment only if the in-use utensil and the food-contact surface of the food preparation table or cooking equipment are cleaned and sanitized at least every 4 hours; (4) In running water of sufficient velocity to flush particulates to the drain (if used with moist food such as ice cream or mashed potatoes); (5) In a clean, protected location (if the utensils, such as ice scoops, are used only with a food that is not potentially hazardous); or (6) In a container of water (if the water is maintained at a temperature of at least 57°C [135°F] and the container is frequently cleaned and sanitized). During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container; (2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon; (3) On a clean portion of the food preparation table or cooking equipment only if the in-use utensil and the food-contact surface of the food preparation table or cooking equipment are cleaned and sanitized at least every 4 hours; (4) In running water of sufficient velocity to flush particulates to the drain (if used with moist food such as ice cream or mashed potatoes); (5) In a clean, protected location (if the utensils, such as ice scoops, are used only with a food that is not potentially hazardous); or (6) In a container of water (if the water is maintained at a temperature of at least 57°C [135°F] and the container is frequently cleaned and sanitized).
Item No.: 18
Site: Buffet-Terrace Buffet Hot Service Line
Violation: Raw hamburger patties were stored next to without any separation from raw flank steaks in the same hotel pan in drawer refrigerator 019763 in front of the grill. The flank steaks, which could be cook-to-order and served undercooked to the passengers, were discarded.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry-except when combined as ingredients-during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
Item No.: 39
Site: Buffet-Terrace Buffet
Violation: One live housefly was observed on the employee side of the buffet
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Pizzeria
Violation: One live housefly was observed by the cold well on the back counter. This area was in service during the inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 29
Site: Bar-Terrace Bar
Violation: The water at the employee handwash station was measured at 78°F.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 26
Site: Bar-Terrace Bar
Violation: The inside bottom of the clean ice bucket in the bar had two black stains that resembled ink when wiped by the inspector.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 22
Site: Galley-Warewash
Violation: The final rinse surface and manifold temperatures in the rack-type dishwash machine did not consistently reach the required temperatures during operation. At least five temperatures were taken at the surface level of the dishwash by both the inspector and crew member and only two times was the temperature above 160°F for the inspector and crew member; the other temperatures ranged from 147°F to 157°F. The water temperature inside the final rinse manifold pipe on the outside of the machine after the booster heater was measured above 180°F by a thermolabel, but the water temperature at the final rinse manifold inside the machine was measured less than 180F by a thermolabel. The final rinse temperature gauge on the dishwash machine showed temperatures primarily around 170°F during operation with the occasional spike to around 190°F. Additionally, the final rinse pressure gauge on the machine showed a between 10-14 psi during this time period. The recommended final rinse pressure listed on the machine's data plate was 20 psi.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 24
Site: Galley-Warewash
Violation: The final rinse surface and manifold temperatures in the rack-type dishwash machine did not consistently reach the required temperatures during operation. At least five temperatures were taken at the surface level of the dishwash by both the inspector and crew member and only two times was the temperature above 160°F for the inspector and crew member; the other temperatures ranged from 147°F to 157°F. The water temperature inside the final rinse manifold pipe on the outside of the machine after the booster heater was measured above 180°F by a thermolabel, but the water temperature at the final rinse manifold inside the machine was measured less than 180F by a thermolabel. The final rinse temperature gauge on the dishwash machine showed temperatures primarily around 170°F during operation with the occasional spike to around 190°F. Additionally, the final rinse pressure gauge on the machine showed a between 10-14 psi during this time period. The recommended final rinse pressure listed on the machine's data plate was 20 psi.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 22
Site: Galley-Warewash
Violation: The wash and pre-wash compartments in the rack-type dishwash machine were heavily soiled during use. A significant amount of food debris was in the bottom of each compartment and on the curtains separating each compartment. Also, several of the top and bottom pre-wash spray nozzles were completely blocked with food debris.
Recommendation: Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
Item No.: 39
Site: Room Service-Deck 5 Galley
Violation: Three live drain flies were observed in the technical compartment housing the warewash pulper system. This area was in operation during the inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 40
Site: Room Service-Deck 5 Galley
Violation: The exit door leading to exterior deck was ajar when the inspector arrived in the area.
Recommendation: Protect entry points where pests may enter the food areas.
Item No.: 16
Site: Galley-Deck 4 Cold Pantry
Violation: A large plastic storage container approximately 6-inches in depth of cut-mixed lettuce was stored in the walk-in refrigerator with an internal temperature at 55°F. The cooling log for this product showed it finished cooling on 14 December 2017 at 14:10 (approximately 24-hours from the time of the inspection) at a temperature of 39°F. This container of mixed lettuce was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 26
Site: Galley-Deck 4 Equipment Storeroom
Violation: Two previously cleaned waffle irons were stored soiled with food residue on the storage shelf. These items were immediately taken to be re-washed.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food-contact surfaces of cooking equipment and pans are kept free of encrusted grease deposits and other soil accumulations.
Item No.: 31
Site: Galley-Deck 4 Cleaning Materials Locker
Violation: The 30-gallon container of 100 ppm chlorine sanitizing solution was not labeled to identify its contents.
Recommendation: Ensure working containers used for storing poisonous or toxic materials such as cleaners and sanitizers taken from bulk supplies are clearly and individually identified with the common name of the material.
Item No.: 19
Site: Galley-Deck 4 Dry Store Locker
Violation: A plastic container of seaweed and powdered grits were not labeled to identify the contents. These products were out of their original containers.
Recommendation: Ensure containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
Item No.: 24
Site: Galley-Deck 4 Warewash
Violation: The final rinse manifold temperature was measured above 200°F by the spray nozzles with a thermolabel during operation. The final rinse temperature gauge read 210°F and 98°C. A significant amount of steam was being produced by the final rinse spray nozzles, but the final rinse surface temperature was still measured at 160°F by the inspector and crew member.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 27
Site: Galley-Deck 4 Pastry
Violation: The bottom of the gaskets around the four doors of the reach-in freezers were heavily soiled with black debris.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 39
Site: Galley-Warewash
Violation: One live housefly was observed on the bulkhead by the handwash sink.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 31
Site: Preparation Room-
Violation: The 30-gallon container of 100 ppm chlorine sanitizing solution was not labeled to identify its contents.
Recommendation: Ensure working containers used for storing poisonous or toxic materials such as cleaners and sanitizers taken from bulk supplies are clearly and individually identified with the common name of the material.
Item No.: 19
Site: Provisions-Meat Freezer 3.12
Violation: Three ice blocks used for ice carvings, which were not made with potable water, were in direct contact with boxes of frozen poultry.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 21
Site: Provisions-Dry Storeroom
Violation: The file cabinet was stored directly on the deck but was not sealed with coving around it or raised on 150 mm (6-inch) legs. The deck under the file cabinet was soiled with debris.
Recommendation: Ensure deck-mounted equipment that is not easily movable is sealed to the deck or elevated on legs that provide at least a 150 mm (6-inch) clearance between the deck and the equipment.
Item No.: 39
Site: Buffet-Staff Mess
Violation: Three live houseflies were observed above the buffet counter. The staff mess was not in service when these flies were observed.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 29
Site: Galley-Tuscan/Red Ginger
Violation: The employee toilet room was locked while the galley was in operation.
Recommendation: Ensure toilet facilities intended for use by galley personnel are not locked when the galley is in service.
Item No.: 28
Site: Galley-Tuscan/Red Ginger
Violation: Clean wine glasses were stored directly under a bulkhead insect control device in the corridor by the employee toilet room and the entrance to the galley.
Recommendation: Do not locate insect-control devices over warewashing, utensil storage areas, equipment, utensils, linens, unwrapped single-service, and single-use articles. Prevent dead insects and insect fragments from falling on clean items.
Item No.: 43
Site: Ventilation-Deck 6 AC Room 4.04
Violation: The water drip eliminators inside AC Unit 4.06 were heavily soiled with white and brown debris.
Recommendation: Keep air handling units clean.
Item No.: 40
Site: Integrated Pest Management-Rat Guards
Violation: The rat guards on the forward mooring lines were U-shaped and did not fully encompass each line.
Recommendation: Ensure rat guards completely encompass each mooring line and are located on the mooring lines at a sufficient distance from the ship to prevent entry of pests onto the ship.
Item No.: 08
Site: Galley-Tuscan/Red Ginger
Violation: Water was consistently leaking from the relief vent on the reduce pressure backflow prevention assembly for the automatic hood cleaning system.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 39
Site: Bar-Barista
Violation: One live housefly was observed under the sneeze shield on the small buffet counter by the bar. No food was on the buffet counter during the inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Provisions-Dry Storeroom
Violation: The file cabinet was stored directly on the deck but was not sealed with coving around it or raised on 150 mm (6-inch) legs. The deck under the file cabinet was soiled with debris. This file cabinet did not contain files, but food.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program