Cruise Ship: Silver Muse Cruise Line: Silversea Inspection Date: 12/18/2017 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Bunkering
Violation: The inspector and engineering team arrive at the bunker station at 10:40 AM and found the ship was actively bunkering water. No one in the inspection team was aware that the ship had started bunkering potable water. One of the engineers immediately went to the bunker station to calibrate the chlorine and pH. After calling the bridge and verifying with the engine control room, it was determined that bunkering had started at 10:30 AM. At 11:15 AM, the inspector arrived at the Deck 1 bunkering station and began testing. The inspector's three pH test results were all above 8.40, and the crew member's pH test results had two values above 8.40 and one value of 7.91. The analyzer was reading a pH value of 7.26 during all three tests and was immediately recalibrated. The inspector returned to the Deck 1 bunker station at 12:22 PM and verified the pH values were below 7.8.
Recommendation: Adjust the free halogen residual level to at least 2.0 mg/L (ppm) within 30 minutes of the start of the bunkering and production processes.
Item No.: 44
Site: Potable Water-Bunkering
Violation: The inspector and engineering team arrive at the bunker station at 10:40 AM and found the ship was actively bunkering water. No one in the inspection team was aware that the ship had started bunkering potable water. One of the engineers immediately went to the bunker station to calibrate the chlorine and pH. After calling the bridge and verifying with the engine control room, it was determined that bunkering had started at 10:30 AM.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP-during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 08
Site: Potable Water-Nontestable Device Log
Violation: The nontestable backflow prevention device log did not list any inspection results from the inspections conducted in April 2017.
Recommendation: Inspect backflow prevention devices periodically and replace any failed units.
Item No.: 08
Site: Potable Water-Incinerator
Violation: The water line after the reduced pressure backflow assembly on the hot water supply line to the incinerator was striped blue to indicate potable water.
Recommendation: Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Item No.: 08
Site: Potable Water-Deck 10 Bridge Window Washing
Violation: The water lines after the reduced pressure backflow assemblies on the hot and cold water lines for the bridge window washing were striped blue indicating potable water.
Recommendation: Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Item No.: 08
Site: Potable Water-Hi-Fog
Violation: The water line after the reduced pressure backflow assembly on the hi-fog line was striped blue indicating potable water.
Recommendation: Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Item No.: 10
Site: Recreational Water Facilities-Shock Halogenation
Violation: The initial free-residual halogen level at the start of the daily shock halogenation for each whirlpool spa and spa pool was recorded as below 10 ppm each night. The recorded free-residual halogen level at the end of the one-hour shock halogenation was above 10 ppm.
Recommendation: Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
Item No.: 10
Site: Recreational Water Facilities-Spa Pool
Violation: The spa pool, which was deeper than 1 meter, did not have a shepherd's hook, flotation device, or depth markers.
Recommendation: Provide a rescue or shepherd's hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency. Ensure the pole of the rescue or shepherd's hook is long enough to reach the center of the deepest portion of the pool from the side plus 2 feet. Ensure it is a light, strong, nontelescoping material with rounded, nonsharp ends. Ensure the approved flotation device includes an attached rope that is at least 2/3 of the maximum pool width. Prominently display the depth of each RWF that is deeper than 1 meter (3 feet) so that it can be seen from the deck and in the pool. Label depth markers in both feet and meters. Additionally, install depth markers for every 1 meter (3 feet) change in depth.
Item No.: 43
Site: Ventilation-AC Fan Room 10.4
Violation: The back bulkhead above the condensation collection pan in AC Unit AP1042 was soiled with black debris.
Recommendation: Keep air handling units clean.
Item No.: 35
Site: Galley-La Terrazza Dishwash Area
Violation: The rack type dishwasher in the La Terrazza galley dishwash area was steadily leaking water from the final rinse compartment. Water was observed pooling on the deck below.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 22
Site: Galley-La Terrazza Dishwash Area
Violation: The rack type dishwasher in the La Terrazza galley dishwash area was steadily leaking water from the final rinse compartment. Water was observed pooling on the deck below.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 24
Site: Dining Room-Indochine Portside Preparation Area
Violation: The chlorine concentration of the sanitizing bucket located in the Indochine portside preparation area was less than 50 ppm. Staff emptied the bucket and replaced the sanitizing solution.
Recommendation: Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 22
Site: Galley-Starboard Dishwash Area
Violation: The rack type dishwasher in the starboard dishwash area was out-of-order since 15 Dec 2017 due to a malfunctioning part inside. Staff placed repair order # 385678 and stated the part would arrive today (18 Dec 2017).
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 20
Site: Bar-Atlantic Bar Coffee Station
Violation: The two coffee machines in the Atlantic bar coffee station had slotted fasteners located on the splash zone adjacent to the dispensing fixture. These fasteners were free of soil during the inspection; however, they were difficult to clean.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 19
Site: Galley-Hot Buffet Line
Violation: The serving tong for the hamburgers located on the hot buffet line was inside the tray of hamburgers with the tong handle resting on top of hamburgers ready for service. Crew was lined up at the buffet for service.
Recommendation: During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container; (2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon; (3) On a clean portion of the food preparation table or cooking equipment only if the in-use utensil and the food-contact surface of the food preparation table or cooking equipment are cleaned and sanitized at least every 4 hours; (4) In running water of sufficient velocity to flush particulates to the drain (if used with moist food such as ice cream or mashed potatoes); (5) In a clean, protected location (if the utensils, such as ice scoops, are used only with a food that is not potentially hazardous); or (6) In a container of water (if the water is maintained at a temperature of at least 57°C [135°F] and the container is frequently cleaned and sanitized).
Item No.: 19
Site: Provisions-Grocery Freezer
Violation: A storage rack was stored upright with the legs resting on a stored pallet of 10 kg unsalted butter in cardboard boxes. Staff relocated this rack so it was no longer resting upright.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 26
Site: Bar-Pool Bar
Violation: The coffee machine in the pool bar had slotted fasteners located on the splash zone adjacent to the dispensing fixture. The fastener located to the left of the dispenser was soiled with brown debris.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Bar-Dolce Vita Bar
Violation: The coffee machine in the Dolce Vita bar had slotted fasteners located on the splash zone adjacent to the dispensing fixture. These fasteners were free of soil during the inspection; however, they were difficult to clean.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 20
Site: Bar-Pool Bar
Violation: The coffee machine in the pool bar had slotted fasteners located on the splash zone adjacent to the dispensing fixture.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.