Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Arcadia Cruise Line: P&O Cruises Inspection Date: 02/07/2018 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log
Violation: For the log dated January 9-April 19, 2018, many entries under the Underlying Illness column were left blank.
Recommendation: Ensure the Underlying Illness column is not left blank. If there is no underlying illness, language such as NIL, n/a, or none is acceptable.
Item No.: 10
Site: Recreational Water Facilities-Spa Pool Sand Filter Sedimentation Test
Violation: The results for the sedimentation test conducted on January 11 stated there was excessive organic material and the sand would be replaced. As of the date of the inspection the sand had not yet been replaced and there was no work order. Staff stated that filter backwashing had been increased to daily instead of every three days, and the test would be repeated on February 11; if excessive organic material was found again, the sand would be replaced. However, there was no written documentation of this procedure, no work orders, and no documentation that the sand filters were being backwashed every day.
Recommendation: Examine granular filter media for channels, mounds, or holes. Inspect a core sample of the filter media for excessive organic material accumulation using a recommended sedimentation method. For whirlpool spas and spa pools, ensure inspections and sedimentation tests are done monthly. For all other RWFs, ensure inspections and sedimentation tests are conducted quarterly. Change granular filter media for whirlpool spas and spa pools based on the inspection and sedimentation test results or every 12 months, whichever is more frequent. For all other RWFs, change granular filter media based on the inspection and sedimentation results or per the manufacturer's recommendations, whichever is more frequent. Record the results of both the filter inspection and sedimentation test.
Item No.: 08
Site: Potable Water-Tank Maintenance
Violation: The documentation for the tank superchlorination of tank 3 port conducted on December 7, 2017 stated 'Tank superchlorinated to 50 ppm (see linked document).' The linked document contained photos with no additional information about the superchlorination procedures.
Recommendation: Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service.
Item No.: 09
Site: Recreational Water Facilities-Neptune Swimming Pool
Violation: Between 11:15 and 11:25 am, the free chlorine level was measured at 0.46, 0.41, 0.40, and 0.35 ppm in different parts of the swimming pool. The pool was open at the time of the inspection and one bather was in the pool. Staff responded immediately to close the pool. In the machinery room at 11:30 am, the chlorine analyzer read 0.38 ppm and a manual test was 0.42 ppm free chlorine. Staff immediately identified a malfunction of the dosing pump as the cause of the low chlorine level. The chart-recorder chart showed that the free chlorine level had been dropping since approximately 10 am. At 10 am, the free chlorine was recorded on the chart as 2.25 ppm. At 10:45 am, the chlorine dropped below 1 ppm. Staff stated the set point for the low chlorine alarm was 1.4 ppm, which was recorded on the chart at between 10:30 and 10:45 am. An alarm sounded in the engine control room at 11:04 am, but no one responsible for the recreational water facilities was notified.
Recommendation: Maintain a free residual halogen in recirculated RWFs in the following ranges: (1) swimming pools, between 1.0 and 5.0 mg/L (ppm).
Item No.: 10
Site: Recreational Water Facilities-Aquarius Swimming Pool
Violation: The shepherd's hook was telescoping and did not reach the center of the deepest portion of the pool from the side plus two feet at the shortest length.
Recommendation: Ensure the pole of the rescue or shepherd's hook is long enough to reach the center of the deepest portion of the pool from the side plus 2 feet. Ensure it is a light, strong, nontelescoping material with rounded, nonsharp ends.
Item No.: 10
Site: Recreational Water Facilities-Swimming Pool Safety Signs
Violation: The safety signs for both swimming pools stated 'Shower before entering the whirlpool spa' and 'Maximum bather load for the whirlpool spa is 15 persons.'
Recommendation: Ensure the safety sign refers to the correct recreational water facility.
Item No.: 20
Site: Bar-Espresso Machines
Violation: The newly-installed espresso machines in the Neptune, Aquarius and Spinnakers bars had slotted fasteners in the coffee making filter. Staff stated these machines were located in other bars as well.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 36
Site: Pantry-Neptune
Violation: The light intensity behind and around the ice machine was less than 220 lux. This was written on the previous inspection. Staff provided documentation that this would be corrected during an upcoming cruise.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 19
Site: Bar-Spinnakers
Violation: Three opened bottles of liquors with pour spouts were in the speed rail directly in front of the handwashing station. The user had to be very careful not to lean directly on the bottles while washing hands, and not to drip water on the bottles while reaching for the paper towels. The bottles and speed rail were removed immediately.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 28
Site: Preparation Room-
Violation: The soiled end of the warewash counter was directly adjacent to the clean storage rack, such that clean items could be easily contaminated.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 39
Site: Preparation Room-
Violation: One small fly was in this room.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 26
Site: Buffet-Portside Cold Buffett Deck Nine
Violation: One plate stored on the rack for service was soiled with brown and black debris on the food contact surface. This plate was removed for rewash. This area was in service.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 39
Site: Buffet-Portside Coffee Station Deck Nine
Violation: One live fruit fly was observed flying in front of the coffee station. This area was in service.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 19
Site: Buffet-Portside Cold Buffet Line Deck Nine
Violation: One uncovered bowl out for service was stored upright to the right of cold buffet line. This bowl was removed. This area was in service.
Recommendation: During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
Item No.: 19
Site: Buffet-Starboard Bread Buffet Line Deck Nine
Violation: One plate stored on the counter for service was soiled with black debris on the food contact surface. This plate was removed for rewash. This area was in service.
Recommendation: During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
Item No.: 19
Site: Buffet-Starboard Buffet Line Deck Nine
Violation: Fourteen plates were stored upright and without cover to the right of the toaster oven. These plates were out for service. Staff removed these plates. This area was in service.
Recommendation: During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
Item No.: 34
Site: Galley-Scullery Deck Nine
Violation: An internal pipe underneath the wash compartment of the rack-type dishwashing machine was steadily dripping water onto the deck below. Water was observed pooled on the deck below.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 22
Site: Galley-Scullery Deck Nine
Violation: The rack type dishwashing machine was emitting excessive steam from the clean end of the machine. The curtains on the outside of the clean side of the machine only covered half of the machine exit. Staff stated this was the recommendation of the manufacturer. When the machine was opened, the inside was filled with an excessive amount of steam. Staff could not determine the source of the steam, and placed the machine out of service.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 27
Site: Galley-Portside Italian Pantry Deck Nine
Violation: There was approximately a 1 mm accumulation of water and brown sediment at the bottom of the technical space for the hood cleaning system.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 39
Site: Galley-Sindu Deck Eleven
Violation: One live fruit fly was observed flying by the starboard entrance to the Sindhu galley. This area was not in service.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 34
Site: Galley-Sindu Deck Eleven
Violation: The drain line exiting the in use sanitizing compartment of the 3-compartment sink was steadily dripping from the junction between two of the pipes. Water was dripping to the deck and observed pooling.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 34
Site: Galley-Portside Hot Service Line Deck Three
Violation: The leftmost light fixture located above the hot service line was steadily leaking water from the junction where the fixture met the deckhead onto the deck below. Water was also pooling on the counter directly in front of the flat top grill. Staff stated this leak was due to a pipe located above this fixture. Staff placed a bucket underneath this leak as a temporary measure.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 37
Site: Galley-Hot Galley Deck Three
Violation: Combination oven # 3 was dripping water from the front of the oven along the right side. Water was observed pooling on the deck below. Staff identified steam escaping from the combination oven and condensing on the metal surface as the cause of the leak. Staff placed the oven out of service.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 39
Site: Galley-Hot Galley Deck Three
Violation: One live fruit fly was observed flying in front of the entrance to the portside hot galley. This area was in service.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 34
Site: Galley-Potwash Station Deck Three
Violation: The drain line exiting from the mechanical potwash machine was steadily dripping water from the elbow shaped joint. Water was dripping to the deck and was observed pooling.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 20
Site: Galley-Coffee Station Deck Three
Violation: The digital coffee machine located in this area had three slotted fasteners located approximately three inches above the dispenser. These fasteners were not soiled. Staff stated the ship recently received this machine.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 08
Site: Galley-Ice Station Deck Three
Violation: The two refrigerant lines and one potable water line entering each of the two ice machines located in this area were stripped green and blue.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 34
Site: Galley-Potwash Station Deck Three
Violation: The drain line exiting from the wash compartment of the conveyor-type dishwashing machine was steadily dripping water from the elbow shaped joint. Water was dripping to the deck and was observed pooling.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 20
Site: Galley-Ocean Grille Coffee Station Deck Two
Violation: The digital coffee machine located in this area had three slotted fasteners located approximately three inches above the dispenser. These fasteners were not soiled. Staff stated the ship recently received this machine.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 16
Site: Galley-Cold Galley Deck Two
Violation: A tray of 24 fruit cups stored in the undercounter refrigeration unit were on temperature control with a discard sticker dated 'FRI.' It was not clear which Friday the fruit must be discarded by. Staff stated this was an error and the discard sticker should have included the actual date of 'FRI 09/02.' This tray was relabeled.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
Item No.: 28
Site: Galley-Hot Service Line Deck Two
Violation: Four plates out for service were stored in the plate dispensing cart wet. This cart was located in front of the hot service line. The entire cart of plates was removed for rewash.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 22
Site: Galley-Dishwashing Station Deck Two
Violation: When the inspector arrived in the area, an engineer was working on the conveyor type dishwashing machine. The bottom of the wash compartment was open. An excessive amount of steam was observed inside this compartment and water was steadily dripping onto the deck below. An large amount of water was observed pooled beneath this leak. Approximately five minutes later, staff reported this conveyor type dishwashing machine was repaired. The inside of the machine was closed and was in service. Water still observed dripping from the bottom of the wash compartment onto the deck below. Water was still pooled on the deck below this leak.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 33
Site: Buffet-Crew Mess
Violation: Missing grout was observed between the two tiles on the corner of the two sides of the crew buffet line. This created a hard to clean space.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 34
Site: Galley-Dishwashing Station
Violation: The sink in front of the dirty end of the rack type dishwashing machine was filled with a brown, cloudy liquid. Staff stated this sink was used to clean utensils prior to entering the dishwashing machine. An excessive amount of food debris was observed in the collection receptacle beneath the drain of this sink. Staff began working to unclog the drain in the pipe below this sink.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 34
Site: Galley-Potwash Station
Violation: The drain line exiting the in use rinse sink was steadily dripping to the deck below. Water was observed pooling on the deck.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 28
Site: Buffet-
Violation: One plate was stored in plate holder wet. This plate holder was located to the right of the hot buffet line. This plate was removed for rewash.
Recommendation:
Item No.: 33
Site: Food Service General-Pooled Water
Violation: There were multiple leaks identified throughout the food service areas that led to water pooling on the deck.
Recommendation: Ensure water does not pool on the deck.
Item No.: 27
Site: Galley-Portside Hot Service Line Deck Three
Violation: The leftmost light fixture located above the hot service line was steadily leaking water from the junction where the fixture met the deckhead onto the deck below. Water was also pooling on the counter directly in front of the flat top grill. Staff stated this leak was due to a pipe located above this fixture. Staff placed a bucket underneath this leak as a temporary measure.
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program