|
|
|
Item No.:
20
|
|
Site:
Galley-Bakery
|
|
Violation:
The inspector measured the temperature twice of a half-pound block of butter stored in undercounter refrigeration unit # 1 and recorded the temperatures at 54°F and 52°F. The inspector measured the internal temperature of this refrigeration unit with a recording thermometer and recorded the temperature at 59°F. The internal thermometer inside this unit recorded the temperature at approximately 50°F. This block of butter was immediately discarded. No other items were stored in this refrigeration unit.
|
|
Recommendation:
Ensure equipment for cooling and heating food, and holding cold and hot food, is sufficient in number and capacity to maintain potentially hazardous food temperatures. Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
|
|
|
Item No.:
33
|
|
Site:
Galley-Refrigeration Unit # 5
|
|
Violation:
Refrigeration unit # 5 was leaking water from the evaporative condenser inside of the unit. Staff placed two plastic trays directly underneath this leak to collect dripping water. Water was observed dripping onto the top of the trays. Additionally, water was observed collecting on top of the plastic hotel tray containing garlic and another hotel tray containing sliced vegetables.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
08
|
|
Site:
Galley-
|
|
Violation:
The backflow prevention device for the left combination oven was leaking heavily. Water was observed pooled on the deck below. The inspector wiped off the device with a paper towel, and the paper towel became excessively wet. The inspector removed the wet paper towel and applied a dry paper towel over the device. This dry paper towel become excessively moist immediately.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-
|
|
Violation:
The backflow prevention device for the left combination oven was leaking heavily. Water was observed pooled on the deck below.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Decks
|
|
Violation:
The tiles and grout in the main galley, passenger buffet line, and beverage station were in disrepair. At least ten tiles inside the main galley were cracked. Additionally, there were numerous gaps in the grouting between the tiles. On the employee side of the buffet counter, at least five large tiles were cracked and had recessed grout, making this area difficult to clean. This was noted during the inspection of December 2017. At least two tiles in the beverage station were cracked and had recessed grout, making this area difficult to clean.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
16
|
|
Site:
Dining Room-Restaurante a la Carta
|
|
Violation:
The consumer advisory on the menu for the Restaurante a la Carta did not contain 'especially if you have certain medical conditions.' This was noted during the last inspection of December 2017. Additionally, this menu was written in both Spanish and English; however, the consumer advisory on the menu was only written in Spanish.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
16
|
|
Site:
Galley-Bakery
|
|
Violation:
The inspector measured the temperature twice of a half-pound block of butter stored in undercounter refrigeration unit # 1 and recorded the temperatures at 54°F and 52°F. The inspector measured the internal temperature of this refrigeration unit with a recording thermometer and recorded the temperature at 59°F. The internal thermometer inside this unit recorded the temperature at approximately 50°F. This block of butter was immediately discarded. No other items were stored in this refrigeration unit.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
|
|
|
Item No.:
27
|
|
Site:
Food Service General-Technical Space
|
|
Violation:
The technical space above the refrigeration units in the food areas were soiled with moisture and a brown residue. This was observed in the main galley, the beverage station, and the provision thawing refrigerators. This was noted during the last inspection of December 2017.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
18
|
|
Site:
Galley-Refrigeration Unit # 4
|
|
Violation:
There was a covered bowl of pesto stored on the bottom shelf of this refrigeration unit, directly underneath one hotel tray containing white fish, one hotel tray containing salmon, one hotel tray containing beef, and one hotel tray containing pork loin. Staff removed this covered bowl of pesto and placed it on the top shelf.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry-except when combined as ingredients-during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
19
|
|
Site:
Galley-Refrigeration Unit # 5
|
|
Violation:
Refrigeration unit # 5 was leaking water from the evaporative condenser inside of the unit. Staff placed two plastic trays directly underneath this leak to collect dripping water. Water was observed dripping onto the top of the trays. Additionally, water was observed collecting on top of the plastic hotel tray containing garlic and another hotel tray containing sliced vegetables.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
36
|
|
Site:
Galley-
|
|
Violation:
The light intensity to the left of refrigeration unit # 8 was insufficient. The inspector measured a maximum light intensity of 85 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Galley-
|
|
Violation:
The light intensity to the left of the portside entrance to the main galley was insufficient. The inspector measured a maximum light intensity of 175 lux. The only light in this area was an emergency light, which was not in operation.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
There were numerous errors identifying incorrect times when a temperature of 41°F or below was reached in the ship's cooling logs - showing the four hour time limit to cool potentially hazardous foods was exceeded. The main galley cooling log, dated 18 March 2018, identified cut vegetables began cooling at 21:00 with an initial temperature of 50°F. The log identified these vegetables stopped cooling at 10:42 with a final temperature of 40°F. A tray of sliced vegetables began cooling at 20:00 on 12 March 18 with an initial temperature of 51°F. The log identified these vegetables stopped cooling at 9:40 with a final temperature of 40°F. A tray of sliced onions began cooling at 20:30 on 12 March 18 with an initial temperature of 50°F. The log identified these onions stopped cooling at 10:00 with a final temperature of 40°F. In each of these instances, the log identified the four hour time frame to cool from 70°F to 41°F was exceeded. Staff stated this was an error switching the time from a 24-hour format to a 12-hour format. These logs were reviewed and signed by management.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
One hotel tray containing cooked ground beef and one hotel tray containing cooked, shredded beef were observed in refrigeration unit # 8. Both of these trays were dated '03-18-18 to 03-24-18.' The cooling log identified one instance of beef cooled on 18 March 18 from a temperature of 150°F beginning at 15:30 to 40°F at 18:30. Staff stated this cooling log entry referred to the cooked shredded beef. Staff stated the ground beef was not entered into the ship's cooling log. This unit was on temperature control. These logs were reviewed and signed by management.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
20
|
|
Site:
Galley-
|
|
Violation:
The cutting board resting on top of the counter above refrigeration unit # 5 was heavily scored with numerous deep pits. This cutting board was out for service.
|
|
Recommendation:
Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
A hotel tray containing bowls of crème brûlée was stored in refrigeration unit # 5; however, this tray of crème brûlée was not identified in the ship's cooling log. These bowls of crème brûlée were date marked '03-15-18 to 03-21-18.' This unit was on temperature control. The cooling logs were reviewed and signed by management.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
27
|
|
Site:
Galley-Crew Galley Preparation Area
|
|
Violation:
The top of the knife sanitizing machine in the crew galley preparation area, the top of the bulkhead divider between the crew galley preparation area and the butcher, the top of the knife sanitizing machine in the butcher, and the top of the divider between the butcher and the pantry were all visibly soiled with dust and a brown colored debris. The inspector rubbed four different alcohol wipes over each of these areas, and these wipes became soiled with a brown colored residue. Staff recleaned this area during the inspection.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Galley-Walk-In Refrigeration Unit # 7
|
|
Violation:
The evaporative condenser unit along the side of walk-in refrigeration unit # 7 was dripping from the right side. A layer of moisture was observed on the deck below this leak. No food items were stored underneath this leak.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
The ship's cooling log dated 21 February 2018 identified salami began cooling at 18:08 with an initial temperature of 44°F. The boxes for the final temperature and the time the final temperature were achieved were left blank. This cooling log was reviewed and signed by management.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
*
|
|
Site:
Galley-Glasswash Station
|
|
Violation:
A pipe exiting the potable water line from the sink at the glasswash station was not attached to any piece of equipment and dead ended to the right of the of the hood-type glasswash machine. Staff stated this pipe used to be connected to a machine; however, the machine was removed and the pipe was cut.
|
|
Recommendation:
Ensure the potable water system is free of dead ends where potential waterborne bacteria is able to grow.
|
|
|
Item No.:
37
|
|
Site:
Galley-Dishwash Station
|
|
Violation:
While the rack-type dishwashing machine was in operation, an excessive amount of steam was observed exiting from both the clean end and the dirty end of this dishwashing machine. This steam was observed rising to the deckhead above and collecting on the deckhead as condensation. Condensation on the deckhead was observed above clean items stored on racks in this area. Condensation was not observed dripping onto the clean items below.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
|
|
|
Item No.:
33
|
|
Site:
Galley-Dishwash Station
|
|
Violation:
While the rack-type dishwashing machine was in operation, an excessive amount of steam was observed exiting from both the clean end and the dirty end of the machine. This steam was observed rising to the deckhead above and collecting on the deckhead as condensation. Condensation on the deckhead was observed above clean items stored on racks in this area. Condensation was not observed dripping onto the clean items below.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
40
|
|
Site:
Galley-Dishwash Station
|
|
Violation:
The door on the starboard side of the galley between the clean end of the conveyor-type dishwashing machine and the clean storage rack for pots and pans was left open for a period of approximately twenty minutes around 11:45. The inspector instructed staff multiple times to shut this door. This door opens into a corridor that has a door, which opens to the outside of the ship approximately one meter away. A visible gap was observed along each side and the bottom of this exit door, which allowed light to filter through. The inspector returned to this area at 14:30 and observed this door adjacent to the dishwashing area was reopened. The inspector instructed staff to close this door.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash Station
|
|
Violation:
The final rinse spray nozzles of the rack-type dishwashing machine were unable to produce an effective fan-like pattern. A steady stream of water was observed dripping from the junction between the final rinse manifold and the machine piping. This machine was in operation.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
24
|
|
Site:
Galley-Dishwash Station
|
|
Violation:
The rack-type dishwashing machine was unable to achieve a utensil surface temperature of 160°F or a water temperature at the manifold of 180°F when tested by the inspector. The inspector placed a maximum registering thermometer through the final rinse cycle and achieved a maximum temperature of 149.9°F. Additionally, the inspector placed a temperature thermolabel onto the final rinse manifold. The thermolabel did not change color to black to signify a temperature of 180°F had been achieved. The inspector tried a second attempt to achieve the appropriate temperature for the final rinse; however, was unable to do so. The inspector placed a thermolabel onto the plate surface and a maximum registering thermometer through the final rinse cycle. The thermometer recorded a maximum temperature of 154.5°F. Additionally, the thermolabel attached to the plate surface did not change color to black to signify a temperature of 160°F had been reached at the plate surface. The inspector placed an additional thermolabel on the final rinse manifold, and this thermolabel did not change color to black to signify a temperature of 180°F had been reached. The inspector tried a third attempt to achieve the appropriate final rinse temperature; however, was unsuccessful. The inspector measured the final rinse temperature with a maximum temperature recording thermometer attached to a long stick. The maximum temperature recorded was 156.4°F. Additionally, the inspector observed the temperature thermolabel attached to the final rinse manifold did not change colors to signify a temperature of 180°F was achieved at the manifold. The temperature gauge panel identified the final rinse temperature was 163°F. Staff placed this rack-type dishwashing machine out of service.
|
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
|
|
|
Item No.:
23
|
|
Site:
Galley-Potwash Station
|
|
Violation:
The hood-type potwash machine was unable to achieve a wash temperature of 150°F when measured by the inspector. The inspector used a thermocouple to measure the temperature of the machine during the wash and final rinse cycle. The maximum temperature registered by the thermocouple during the wash cycle was 142°F. The thermocouple did record a temperature of 161°F during the final rinse cycle.
|
|
Recommendation:
Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (1) 74°C (165°F) for a stationary-rack, single-temperature machine; (2) 66°C (150°F) for a stationary-rack, dual-temperature machine; (3) 71°C (160°F) for a single-tank, conveyor, dual-temperature machine; (4) 66°C (150°F) for a multi-tank, conveyor, multi-temperature machine.
|
|
|
Item No.:
26
|
|
Site:
Galley-Beverage Station
|
|
Violation:
Inside the forward ice machine, the ledge above the ice cuber panel and the ice thickness probe was soiled with a brown and black residue. The inspector rubbed an alcohol wipe over these food-contact surfaces, and the wipe became soiled with a black residue. This was noted during the last two inspections of July 2017 and December 2017.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
21
|
|
Site:
Galley-Beverage Station
|
|
Violation:
A cord from the ice machine was observed resting on the counter behind the coffee machine. The inspector rubbed an alcohol wipe underneath this cord, and the alcohol wipe became soiled with a black residue.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-Beverage Station
|
|
Violation:
A cord from the ice machine was observed resting on the counter behind the coffee machine. The inspector rubbed an alcohol wipe underneath this cord, and the alcohol wipe became soiled with a black residue.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Galley-Beverage Station
|
|
Violation:
Water was observed pooled on the deck underneath the forward ice machine. Water was not observed dripping from this machine.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
22
|
|
Site:
Galley-
|
|
Violation:
The sanitizing solution to the right of refrigeration unit # 8 was cloudy. Staff replaced this solution. This area was in service.
|
|
Recommendation:
Ensure the wash, rinse, and sanitize solutions are maintained clean.
|
|
|
Item No.:
36
|
|
Site:
Buffet-
|
|
Violation:
The light intensity on the left side of the beverage station was insufficient. The inspector measured a maximum light intensity of 190 lux. This was noted during the inspection of December 2017. Staff stated an additional light was added above the beverage station; however, this additional light was unable to provide adequate lighting on the left side of the beverage station.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
36
|
|
Site:
Buffet-
|
|
Violation:
The light intensity at the tray station was insufficient. The inspector measured a maximum light intensity of 195 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
21
|
|
Site:
Buffet-
|
|
Violation:
The buffet counter in front of the forward hot serving bain-marie was cracked on either side. This created a difficult to clean surface.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Restaurant a la Carta
|
|
Violation:
The light intensity at the waiter station could not be raised to 220 lux for cleaning operations. This was noted during the inspection of December 2017.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
40
|
|
Site:
Dining Room-Restaurant a la Carta
|
|
Violation:
The starboard door between the Restaurant a la Carta and the outside of the ship had a visible gap approximately 1/2 inch thick between the bottom of the door and the deck below. Light was observed entering through this gap. There were no pests observed in this area.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|
|
Item No.:
19
|
|
Site:
Buffet-
|
|
Violation:
Two food-dispensing utensils were observed completely resting inside a tray of French fries and a tray of fried chicken. The hand contact portion of the utensils were observed touching pieces of fried chicken and French fries out for service. These food-dispensing utensils were removed for rewash.
|
|
Recommendation:
During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container; (2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon; (3) On a clean portion of the food preparation table or cooking equipment only if the in-use utensil and the food-contact surface of the food preparation table or cooking equipment are cleaned and sanitized at least every 4 hours; (4) In running water of sufficient velocity to flush particulates to the drain (if used with moist food such as ice cream or mashed potatoes); (5) In a clean, protected location (if the utensils, such as ice scoops, are used only with a food that is not potentially hazardous); or (6)
In a container of water (if the water is maintained at a temperature of at least 57°C [135°F] and the container is frequently cleaned and sanitized).
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dry Storage
|
|
Violation:
The dry storage provisions room was moved into a new space, which lacked coving between the deck and bulkhead. Additionally, the deck was not constructed and maintained for easy cleaning. The deck had numerous bumps and ridges and was not smooth. Additionally, the bulkhead had small, 1 cm openings around the top of the room. These small 1 cm openings into the space technical space behind were directly above food storage and occurred at intervals of approximately three feet from each other.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dry Storage
|
|
Violation:
Accumulation of greater than one day's debris was observed underneath a rack containing stored bags of sugar and boxes of ketchup.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Vegetable Walk-in Freezer
|
|
Violation:
Water was frozen on the deck, deckhead, bulkheads, the evaporative condenser, and on approximately 50 boxes of food. This was noted during the inspection of December 2017.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Vegetable Walk-in Freezer
|
|
Violation:
Water was frozen on the deck, deckhead, bulkheads, the evaporative condenser, and on approximately 50 boxes of food. This was noted during the inspection of December 2017.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Fish Walk-in Freezer
|
|
Violation:
Water was frozen on the deck, deckhead, bulkheads, the evaporative condenser, and on approximately 20 boxes of food.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Fish Walk-in Freezer
|
|
Violation:
Water was frozen on the deck, deckhead, bulkheads, the evaporative condenser, and on approximately 20 boxes of food.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Vegetable and Fruits Walk-in Refrigerator
|
|
Violation:
The evaporative condenser unit inside the walk-in refrigerator was dripping water from the right side. Water was observed dripping on a cardboard box containing individual heads of iceberg lettuce wrapped in plastic.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Vegetable and Fruits Walk-in Refrigerator
|
|
Violation:
The evaporative condenser unit inside the walk-in refrigerator was dripping water from the right side. Water was observed dripping on a cardboard box containing individual heads of iceberg lettuce wrapped in plastic.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck. Do not store foods: (1) In locker rooms; (2) In toilet rooms; (3) In dressing rooms; (4) In garbage rooms; (5) In mechanical rooms; (6) Under sewer lines that are not continuously sleeve welded; (7) Under leaking water lines, including leaking automatic fire sprinkler heads, or under lines on which water has condensed; (8) Under open stairwells; (9) Under other sources of contamination from nonfood items such as ice blocks, ice carvings and flowers; or (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dairy Walk-in Refrigerator
|
|
Violation:
The evaporative condenser unit inside the walk-in refrigerator was dripping water from the right side. No water was observed dripping onto the boxes of salami stored below. The bulkhead behind the evaporative condenser was covered in a layer of condensation. The items stored under this evaporative condenser were removed.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-International Shore Connection
|
|
Violation:
No backflow prevention device was installed on the international shore connection. This was noted on the previous inspection of December 2017. Documentation was provided to the inspector that showed the backflow prevention device was ordered on 8 March 2018.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (20) international fire and fire sprinkler water connections (install a reduced pressure assembly).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The list of backflow prevention devices was missing information. For example, the quantity of device was listed by deck, but there was no information about what types of devices were installed or the specific location and type of connection. Also, the quantity column for the rows labeled Deck 5 and Galley were blank. This was written on the previous inspection of December 2017.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
Some of the toilets still only had dual check valves with no intermediate atmospheric vent. Staff stated approximately 25 toilets needed atmospheric vacuum breakers (AVBs) and the devices were on order. This was written on the previous two inspections of July 2017 and December 2017. Additionally, the shower hose in each cabin, which was flexible and could touch the deck, was also only protected against backflow with the dual check values on the hot and cold supply line located in the technical compartment. It was discussed one AVB could be placed on the flexible shore hose or each dual check value on the hot and cold supply lines would need to be replaced with a vented backflow prevention device.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (3) cabin shower hoses, toilets, whirlpool tubs, and similar facilities.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Technical Water Connection
|
|
Violation:
No reduced pressure zone assembly backflow prevention device or air gap was installed on the connection line between potable and technical water. Staff stated a device had been ordered. This was written on the previous inspection of December 2017.
|
|
Recommendation:
Ensure the potable water distribution system is maintained free of cross-connections. Protect the potable water system against backflow or other contamination by backflow prevention devices or air gaps. Ensure the permeate lines and distillate lines directed toward the potable water system are also protected.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunker Stations
|
|
Violation:
The bunker hose locker at the aft starboard bunker station had an absorbent cloth at the bottom to soak up excess water, but it also blocked the self-draining holes on the bottom of the locker. The cap on the right filling line at port midship bunker station was missing and the cap on the left filling line was missing a keeper chain. The cap on the right filling line at the forward starboard bunker station was missing.
|
|
Recommendation:
Ensure the potable water filling line has a screw cap fastened by a noncorroding cable or chain to an adjacent bulkhead or surface in such a manner that the cap cannot touch the deck when hanging free. Ensure the hose connections are unique and fit only the potable water hoses. Handle and store all hoses, fittings, water filters, buckets, equipment, and tools used for connection with the bunkering of potable water in a sanitary manner.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunker Pretest
|
|
Violation:
The ship was not taking or recording a chlorine and pH test of the shore side water supply before bunkering.
|
|
Recommendation:
Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunker Records
|
|
Violation:
The time when the chlorine residual level first reached 2.0 ppm and the pH level below 7.8 within the first 30 minutes of bunkering was documented on 31 January 2018, 2 February 2018, 14 February 2018, and 16 February 2018 when only manual samples were taken and no chart recorded was used.
|
|
Recommendation:
Adjust the free halogen residual level to at least 2.0 mg/L (ppm) within 30 minutes of the start of the bunkering and production processes.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Distribution Far Point
|
|
Violation:
The far point analyzer was not equipped with an audible alarm that sounded in a continuously manned space to indicate high or low chlorine levels.
|
|
Recommendation:
Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen readings at the distant point analyzer.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Distribution Far Point
|
|
Violation:
Between the last inspection (27 December 2017) and 8 March 2018, the daily calibration of the far point analyzer was only recorded on the chart recorder on ten different days. The daily calibration of the far point analyzer had been recorded every day from 9 March 2017 until 19 March 2018 (the day of the inspection).
|
|
Recommendation:
Record the daily manual comparison test or calibration either on the recorder chart or in a log.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Distribution Far Point
|
|
Violation:
According the far point chart records, the chlorine level in the distribution system was below 0.2 ppm on 24 January 2018 for approximately 11 hours; 27 January 2018 for approximately 23 hours; 2 February 2018 for approximately 22 hours; 3 February 2018 for 24 hours; 4 February 2018 for 24 hours; 5 February 2018 for approximately 21 hours; 6 February 2018 for 24 hours; 7 February 2018 for approximately 19 hours; 7 February 2018 for approximately 10 hours; 21 February 2018 for approximately 13 hours; 22 February 2018 for 24 hours; and 23 February 2018 for 24 hours. No notations were made on the chart or in the log to explain these low chlorine readings and what corrective actions took place. The chlorine reading on 18 February 2018 was above 5.0 ppm for approximately 9.5 hours. No notations were made on the chart or in the log to explain this high chlorine reading and what corrective actions took place.
|
|
Recommendation:
Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel.
|
|
|
Item No.:
05
|
|
Site:
Potable Water-Distribution Far Point
|
|
Violation:
The far point analyzer was reading between 1.0 ppm and 1.1 ppm when the inspector and crew member took two samples. The inspector had a chlorine value of 3.68 ppm for both tests, and the crew member had a chlorine value of 3.86 ppm for the first test and 3.59 ppm for the second test. The analyzer was recalibrated to 3.6 ppm. The far point analyzer was also out of calibration during the last inspection of December 2017.
|
|
Recommendation:
Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Distribution Far Point
|
|
Violation:
The far point sample line was placed in the overflow drain of the handwash station in the bridge toilet room where the sample point was located, which created a cross connection.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (28) any other connection to the potable water system where contamination or backflow can occur.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Deck 2 Engine Room
|
|
Violation:
The potable water lines to the crew laundry machines were not striped blue or blue/green/blue to indicate potable water.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Deck 2 Forward Old Chlorination Room
|
|
Violation:
All three potable water tanks were not identified and labeled. The potable water piping in this room was not striped blue or blue/green/blue to indicate potable water. Additionally, the potable water piping leaving this room to the combined sample test cock outside the room was not striped blue or blue/green/blue. This sample test cock was not identified and labeled.
|
|
Recommendation:
Identify potable water tanks with a number and the words "POTABLE WATER" in letters at least 13 millimeters (0.5 inch) high. Ensure potable water tanks have labeled sample cocks that are turned down. Identify the sample cocks with the appropriate tank number. Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-AC Fan Room 7
|
|
Violation:
The condensation collection pan inside the AC unit 10, 11, and 8 were not accessible for inspection and no sight glass was installed. The visible ends of the condenser and cooling coils in each AC unit were heavily soiled with black and white debris. In addition, the water drip eliminator in each AC unit were heavily soiled with a white fungi-like substance. These AC units had no condensate drain pan; a drainpipe was installed in the motor housing compartment. This was written on the previous inspection report of December 2017.
|
|
Recommendation:
Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical. Keep air handling units clean. Inspect evaporative condensers at least annually and clean as necessary to remove scale and sediment. Clean cooling coils and condensate pans as necessary to remove dirt and organic material.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Inspection and Maintenance Plan
|
|
Violation:
The ship did not have a written inspection, cleaning, and maintenance plan for its ventilation and AC Units.
|
|
Recommendation:
Ensure vessels have a plan to inspect and maintain HVAC systems in accordance with the manufacturer's recommendations and industry standards. Maintain the written inspection, cleaning, and maintenance plan for the HVAC system on the vessel and available for review during inspections. Ensure documentation of the inspection, cleaning, and maintenance plan is available for review during inspections.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Active Inspections
|
|
Violation:
The ship was only conducting and recording passive inspections of the insect trips located around the ship. No active inspections of the food areas were recorded. Additionally, staff stated that insect traps were located around the garbage holding area of the ship, but passive or active monitoring was not documented.
|
|
Recommendation:
Ensure the IPM Plan sets a schedule for periodic active monitoring inspections, including some at night or during periods of no or minimal activity. Inspect all food areas at a frequency that can quickly detect the evidence of pests, harborage conditions, cleanliness, and protection of outer openings. In nonfood areas, give reasonable care to conduct inspections for the presence of insects, rodents, and other pests. Inspect the garbage handling areas of the vessel at least weekly for the presence of insects, rodents, and other pests. Maintain the results of these inspections in a log.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Incoming Shipments
|
|
Violation:
The ship was not documenting the inspections of the incoming shipments of nonfood items, such as housekeeping and technical supplies.
|
|
Recommendation:
Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
|
|
|
Item No.:
41
|
|
Site:
Other-Bridge Toilet Room
|
|
Violation:
Paper towels were provided for users to open the door, but no sign was installed advising users to use a paper towel to open the door.
|
|
Recommendation:
Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
|
|