Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Borealis Cruise Line: Fred Olsen Cruise Line Inspection Date: 04/09/2018 Inspection Score: 91
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 16
Site: Galley-Dive In
Violation: The food inside refrigerator 8.71 that was on time control was not individually labeled. Only the refrigerator had a red dot on the outside, but the pans including, but not limited to, raw hamburger, cut lettuce, and cut tomatoes did not have a red dot. The time control plan used a color coding system to indicate time, and at the time of the inspection, red dots were used in this area. The area was open for greater than 4 hours for service.
Recommendation: If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours).
Item No.: 33
Site: Bar-Lido
Violation: The portable draft beer dispenser was partially fixed over a synthetic teak deck. The grooves between the panels were difficult to keep clean and were soiled. This was noted on the previous report as a wooden deck.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 26
Site: Buffet-Lido Beverage Stations
Violation: There was black debris inside the nozzles of the water dispensers at both the port and starboard beverage stations.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Buffet-Lido Beverage Stations
Violation: The deck was carpeted at the far right side of the port beverage station where the sweetener packets and tea were located. This was not observed at the starboard beverage station.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 19
Site: Buffet-Starboard Line
Violation: Six serving utensils were placed on top of the heat lamps. This area was not protected by a sneeze guard. The area was open for service and there were guests at the line.
Recommendation: During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
Item No.: 37
Site: Galley-Dishwash
Violation: Condensation collected on the deckhead near the soiled area near the pre-rinse hose. Condensation also collected on the AC vent over the flight type dishwash machine. No clean dishes were impacted.
Recommendation: Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 33
Site: Galley-Dishwash
Violation: Water was dripping through a deckhead hatch onto the flight-type conveyor dishwash machine. Water was dripping form the deckhead over the soiled racks. The source of the water was not known and no clean dishes were impacted.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 22
Site: Galley-Dishwash
Violation: The final rinse gauge of the hood-type glasswash machine registered over 200°F during two cycles (as high as 203°F). A thermolabel was placed on two final rinse manifolds during the second cycle, and it did not register as reaching 200°F. Crew began working on the machine.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 20
Site: Galley-Pastry/Bakery
Violation: The paint had chipped off the rotating arm of the small and large adjacent deck-mounted stand mixers. This created a difficult-to-clean area.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
Item No.: 26
Site: Galley-Pastry/Bakery
Violation: Paint had chipped off the rotating arm of the small deck-mounted stand mixer above the food bowl. A reddish-brown debris had collected in areas where paint had chipped off. The area was in operation and there was a light colored flour in the bowl. There was no red/dark brown food product in use and crew were unable to identify the debris.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Galley-Pastry/Bakery
Violation: A large amount of soiled water collected in a basin of the technical space of upright refrigerator 4.31C. A refrigeration engineer began working on the machine.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Pastry/Bakery
Violation: There were many areas of recessed grout in the area including near the stand mixers and the kettles. Crew noted that deck maintenance in food areas was ongoing.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 39
Site: Galley-Garde Manger
Violation: There was one live fly in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 22
Site: Galley-Dishwash
Violation: The temperature gauge of the final rinse fluctuated as the machine ran, including going below 180°F and above 200°F. Crew noted that when the machine was stopped and then restarted, it could take approximately 30 seconds for the temperature to remain constant. The machine ran for a few minutes and the temperature gauge continued to fluctuate. The inspector was able to measure the proper plate surface temperature at the final rise during her second measurement. A thermolabel placed on the upper final rinse manifold did not indicate that the temperature reached 200°F.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Dishwash
Violation: The rack-type glasswash machine was out of service since the morning of the inspection because the rinse motor was leaking. Crew stated they would replace the gasket.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: 26
Site: Galley-Wine Bar
Violation: There was an excessive amount of black debris on the food-contact surfaces inside the ice machine. The debris covered over half the surface area of the evaporator cover panel on the side that faced the evaporator. The black debris was also noted on the cuber adjustment panel and on the white plastic area above the recirculation bath. The machine was taken out of service for cleaning.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 19
Site: Galley-Ice Station
Violation: There was a blue thread located on a piece of ice in the ice bin.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
Item No.: 37
Site: Galley-Saucier
Violation: Water was dripping from the steam exhaust pipe and there was excessive condensation on the exhaust vent over the pipe. When a paper towel was held to the vent, there was not a significant pull on the paper towel. Water dripped onto a plastic cover of a trolley containing potatoes and pasta on time control.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 22
Site: Galley-Potwash
Violation: The front-loading potwash machine had been out of service since 1 April. Spare parts for the transformer were expected to arrive on 30 April. Crew were utilizing the three compartment sink.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 33
Site: Provisions-Deck A Freezer 14
Violation: There was excessive water and ice on the deckhead, including an icicle that had formed, water that froze near a sprinkler head, and ice trapped in a light fixture. Food was not impacted.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 37
Site: Provisions-Deck A Freezer 14
Violation: Condensation collected around a deckhead hatch over boxes of turkey breast. Water was noted dripping on the cardboard box containing packages of turkey breasts. There was a small amount of ice frozen on the box.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 19
Site: Provisions-Deck A Freezer 14
Violation: Condensation collected around a deckhead hatch over boxes of turkey breast. Water was noted dripping on the box of turkey breasts. There was a small amount of ice frozen on the box.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
Item No.: 33
Site: Provisions-Deck A Freezer 13
Violation: There was an icicle on the deckhead that was a few inches long.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 39
Site: Provisions-Deck B Dry Store 2
Violation: At least ten live weevils and at least five dead weevils were noted on cardboard boxes containing food such as canned tomatoes, on white bags containing beans, on containers of peanuts, on plastic buckets with lids containing food, and on packaging of other food products. The bag of beans was the only food products that did not appear to be sealed. One of the three bags of beans was dumped into a plastic bin. No weevils were noted on the food product. No bags of rice or beans were noted in the area. The pest manager responded and identified the pests as weevils.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 19
Site: Provisions-Deck B Dry Store 2
Violation: At least ten live weevils and at least five dead weevils were noted on cardboard boxes containing food such as canned tomatoes, on white bags containing beans, on containers of peanuts, on plastic buckets with lids containing food, and on packaging of other food products. The bag of beans was the only food products that did not appear to be sealed. One of the three bags of beans was dumped into a plastic bin. No weevils were noted on the food product. No bags of rice or beans were noted in the area.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
Item No.: 39
Site: Bar-Officer's
Violation: There was one fly in this area. The area was not in operation.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 26
Site: Pantry-Sea View
Violation: There was an excessive amount of black debris on the food-contact surfaces inside the ice machine. The debris covered approximately one-third of the surface area of the evaporator cover panel on the side that faced the evaporator. The black debris was also noted on the cuber adjustment panel and on the white plastic area above the recirculation bath. The machine was taken out of service for cleaning. The area was in open for service and there were guests at the bar.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-Ice Machine
Violation: There was excessive black debris on the evaporator panel in the area that faced the evaporator as well as on the gray area of the water recirculation line above the evaporator. The issue was similar to two other ice machines noted previously, but the black debris covered less surface area of the evaporator panel cover.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 09
Site: Recreational Water Facilities-Forward Retreat Whirlpool Records
Violation: On 8 November from 1845-1930 no halogen or pH values were recorded; the note stated no return flow. On 3 April from 1045-1130 the bromine concentration was above 10 ppm; the note stated due to bromine feed and cleaned filter.
Recommendation: Maintain a free residual halogen in recirculated RWFs in the following ranges: (6) whirlpool spas and spa pools, between 3.0 and 10.0 mg/L (ppm) free chlorine or between 4.0 and 10.0 mg/L (ppm) bromine.
Item No.: 06
Site: Potable Water-Microbiological Records for Distribution System
Violation: No microbiological testing was conducted for the potable water distribution system in February.
Recommendation: Collect and analyze a minimum of four potable water samples per month for the presence of E. coli. Collect samples from the forward, aft, upper, and lower decks of the vessel. Change the sample sites each month so that all of the potable water distribution system is effectively monitored. Conduct follow-up sampling for each positive test result.
Item No.: 40
Site: Integrated Pest Management-Rat Guards
Violation: Some of the mooring lines were not completely enclosed and provided access to rats. For example, one rat guard was placed on two mooring lines and did not prevent entry on the bottom of the line. Two other rat guards were not placed on properly and did not prevent entry on the bottom of the lines.
Recommendation: Protect entry points where pests may enter the food areas.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program