Item No.:
04
|
|
Site:
Potable Water-Distribution System
|
|
Violation:
From 2100 on 19 April to 0830 on 21 April the free halogen residual was below 0.2 ppm and for the majority of this period was 0 ppm. Staff stated that the inclement weather caused suction on the ball on the overboard water tank line, which created a vacuum of the potable water distribution system. There were no records to show what the free halogen residual was in the potable water distribution system. On 24 May from 1250-1530, the free halogen residual was below 0.2 ppm; there were no records to indicate why this happened. On 27 January to 0913 on 31 January the halogen residual was below 0.2 ppm and for the majority of this period as 0 ppm. The ship left dry-dock on 26 January and started a new voyage on 27 January. There were no records to indicate why this happened and it was unknown if the low halogen alarm was activated.
|
|
Recommendation:
Provide continuous halogenation of the potable water system using halogenation injection equipment and maintain a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Distribution System
|
|
Violation:
From 2100 on 19 April to 0830 on 21 April the free halogen residual was below 0.2 ppm and for the majority of this period was 0 ppm. Staff stated that the inclement weather caused suction on the ball on the overboard water tank line, which created a vacuum of the potable water distribution system. There were no records to show what the free halogen residual was in the potable water distribution system. On 24 May from 1250-1530, the free halogen residual was below 0.2 ppm; there were no records to indicate why this happened. On 27 January to 0913 on 31 January the halogen residual was below 0.2 ppm and for the majority of this period as 0 ppm. The ship left dry-dock on 26 January and started a new voyage on 27 January. There were no records to indicate why this happened and it was unknown if the low halogen alarm was activated.
|
|
Recommendation:
Maintain the halogen analyzer-chart recorder properly and operate it in accordance with the manufacturer's instructions. Conduct a manual comparison test daily to verify calibration. Calibrate whenever the manual test value is greater than 0.2 ppm higher or lower than the analyzer reading. Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system. In the event of equipment failure, measure the free residual halogen by a manual test kit at the halogen analyzer at least every 4 hours.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Distribution System
|
|
Violation:
There were no records to document if the microbiologic testing was conducted for the potable water distribution system during the month of February.
|
|
Recommendation:
Collect and analyze a minimum of four potable water samples per month for the presence of E. coli. Collect samples from the forward, aft, upper, and lower decks of the vessel. Change the sample sites each month so that all of the potable water distribution system is effectively monitored. Conduct follow-up sampling for each positive test result.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Records
|
|
Violation:
One chart was used to record the free halogen residual for two days (30 April and 1 May).
|
|
Recommendation:
Ensure the halogen analyzer-chart recorder charts have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of (and limited to) 24 hours.
|
|
|
Item No.:
08
|
|
Site:
Dining Room-
|
|
Violation:
Crew were unable to present the inspector with the backflow preventer for the coffee machine.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment.
|
|
|
Item No.:
08
|
|
Site:
Other-Laundry Store Room
|
|
Violation:
Water was continuously dripping from the vacuum breaker backflow prevention device on the potable water line supply to the cleaning chemicals.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
13
|
|
Site:
Food Service General-
|
|
Violation:
There were multiple monitoring issues which contributed to food safety violations including: 1) Crew were unaware that the cooling of melon cut at room temperature needed to be monitored; 2) There were multiple food items in various food and beverage areas that had 8 day discard labels instead of 7 day discard labels; 3) Refrigerators were overloaded with food products that prevented the airflow, which may contribute to potentially hazardous food being out of temperature; 4) Chemicals were stored in close proximity to food-service equipment; and 5) Food was stored in settees which were not constructed to food storage standards.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines. Ensure that the areas of knowledge include: (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control points in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual. Ensure the supervisor or person in charge of food operations on the vessel monitors that: (7) Employees are using proper methods to rapidly cool potentially hazardous foods that are not held hot or are not for consumption within 4 hours; (12) Employees are properly trained in food safety.
|
|
|
Item No.:
16
|
|
Site:
Provisions-Dry Store
|
|
Violation:
Cut honeydew melon in a hotel pan of mixed fruit stored in the upright refrigerator measured 55°F. Cut cantaloupe melon in another hotel pan of mixed fruit stored in the upright refrigerator measured 52°F. Crew measured similar temperatures. Crew stated the melon was cut earlier in the morning and that they were not monitoring the cooling. The items were not listed on the cooling logs. Crew then added the items to the cooling logs. Additionally, cut tomatoes in a bowl of mixed salad measured 44-45°F. Crew reported the tomatoes were not on the cooling log because the temperature when they were cut was lower than 41°F. Crew reported that the salad was prepared the night prior to the inspection. The refrigerator was excessively full with food products. The salad was discarded.
|
|
Recommendation:
Cool potentially hazardous food within 4 hours to 5°C (41°F) or less if prepared from ingredients at ambient temperature.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
During the past month, two pans of penne pasta, a pan of tomato soup, and a pan of chicken soup were cooled. In the final temperature column, 'ICB' was listed to indicate the items were cooled in an ice bath, but no temperature of 41°F or below was listed. Crew reported that they did confirm the temperatures reached 41°F or below.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
16
|
|
Site:
Galley-Undercounter Refrigerator
|
|
Violation:
A hotel pan containing sausage was dated 6 May -13 May. The label was updated.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
|
|
|
Item No.:
16
|
|
Site:
Dining Room-Undercounter Refrigerator
|
|
Violation:
Open containers of whole milk, Greek yogurt, cottage cheese, half and half, and fat free milk were labeled with a discard date of 13 May. The inspection was conducted on 6 May.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
|
|
|
Item No.:
16
|
|
Site:
Bar-Undercounter Refrigerator
|
|
Violation:
Open containers of whole milk, half and half, and fat free milk were labeled with discard dates of 13 May. The inspection was conducted on 6 May.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
|
|
|
Item No.:
16
|
|
Site:
Other-Crew Lounge
|
|
Violation:
Four individual serving packages of cold mozzarella cheese stored in a plastic bin in the undercounter refrigerator were measured between 48-53°F. The cheese was taken from various areas of the plastic container, including on the top and in the center. There was 5 packages of 12 cheeses in the bin. The items were discarded. In a second container of approximately 50 individual servings of mozzarella cheese, three were measured at 47-48°F from the top and middle of the container. The items were provisioned the day prior. Crew measured similar temperatures. The items were discarded. The ambient temperature of the refrigerator was less than 41°F.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
|
|
|
Item No.:
16
|
|
Site:
Other-Crew Lounge
|
|
Violation:
Open containers of rice milk, chai tea latte, and coconut milk did not have legible discard dates.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
During the past month, two pans of penne pasta, a pan of tomato soup, and a pan of chicken soup were cooled. In the final temperature column, 'ICB' was listed to indicate the items were cooled in an ice bath, but no temperature of 41°F for below was listed. Crew reported that they did confirm the temperatures reached 41°F or below.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
|
|
|
Item No.:
17
|
|
Site:
Provisions-Dry Store
|
|
Violation:
Cut honeydew melon in a hotel pan of mixed fruit stored in the upright refrigerator measured 55°F. Cut cantaloupe melon in another hotel pan of mixed fruit stored in the upright refrigerator measured 52°F. Crew measured similar temperatures. Crew stated the melon was cut earlier in the morning and that they were not monitoring the cooling. The items were not listed on the cooling logs. Crew then added the items to the cooling logs and began monitoring the cooling process.
|
|
Recommendation:
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
19
|
|
Site:
Other-Crew Lounge Settees
|
|
Violation:
Many bags of prepackaged food such as chips were stored in the bottom of the settees which were made of unvarnished wood.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck. Do not store foods: (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
|
|
|
Item No.:
19
|
|
Site:
Bar-Lounge Neutral Cabinet
|
|
Violation:
Many bottles of beverages and packaged food was stored in the neutral cabinet in the lounge dining area of the bar. There was no top to the cabinet, so the area was exposed to the technical areas of the plenum above.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination. Do not store foods: (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
|
|
|
Item No.:
19
|
|
Site:
Bar-Lounge Settees
|
|
Violation:
Three boxes of 36 apple juice boxes, multiple bottles of water, four bags of ginger candies, and two mesh bags with greater than 25 packages of coffee each were stored on the soiled deck under the cushion of a settee in the lounge. The settee was composed of painted, unvarnished wood and fabric. Some of the wood was exposed where the paint no longer existed.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck. Do not store foods: (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
|
|
|
Item No.:
20
|
|
Site:
Provisions-Dry Store
|
|
Violation:
There were 3 slotted screws in the food contact area of the salad dryer.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
21
|
|
Site:
Galley-Combination Ovens
|
|
Violation:
The side panel of the combination oven under the window was not completely sealed. There were gaps and seams to the technical areas behind the unit which were difficult to clean. Crew reported they do not routinely remove the panel for cleaning.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Flat Grill
|
|
Violation:
The area above the grease drain around the grease chute had large gaps which exposed the technical areas. This was difficult to clean and included exposed insulation. The area had not yet been fully cleaned as the grill was cooling. Crew reported the unit was just installed and there were plans in place to conduct corrective action later this month when the vessel reaches Petersburg.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Bar-Lounge Settees
|
|
Violation:
Food and beverages were stored under the cushion of the settee which was composed of painted, unvarnished wood and fabric. Some of the wood was exposed where the paint no longer existed. The area was difficult to clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Other-Crew Lounge Settees
|
|
Violation:
Many bags of prepackaged food were stored in the bottom of the settees which were made of unvarnished wood and had difficult-to-clean features.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
26
|
|
Site:
Bar-Self Service Area
|
|
Violation:
The black plastic ice chute was excessively soiled with pink and brown slimy debris. The chute for the water dispenser was soiled with a small amount of brown debris.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Bar-Ice Machine
|
|
Violation:
There was a small amount of black debris on the plastic area of the evaporator. Water flowed over this food-contact area.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Undercounter Neutral Cabinet
|
|
Violation:
Three muffin pans and five flat pans were soiled with greater than a day's accumulation of grease and other food debris on both the food-contact and nonfood-contact surfaces. The items were removed for cleaning.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food-contact surfaces of cooking equipment and pans are kept free of encrusted grease deposits and other soil accumulations.
|
|
|
Item No.:
26
|
|
Site:
Other-Corridor
|
|
Violation:
Excessive brown debris was located on the plastic area above the evaporator and behind the cuber adjustment panel in the ice bin.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-Liquor Room
|
|
Violation:
A previously cleaned drink dispenser stored in the liquor room had dried fruit residue in the dispensing nozzle.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-Undercounter Neutral Cabinet
|
|
Violation:
Three muffin pans and five flat pans were soiled with greater than a day's accumulation of grease and other food debris on both the food-contact and nonfood-contact surfaces. The items were removed for cleaning.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Combination Ovens
|
|
Violation:
The bottom of the left combination oven was excessively soiled with greater than a day's accumulation of debris. Crew began cleaning the oven.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Other-Crew Lounge
|
|
Violation:
The counter under the microwave was soiled with greater than a day's accumulation of food debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Dining Room-Settees
|
|
Violation:
Linens, paper napkins, and paper towels were stored on the deck in the settees.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
28
|
|
Site:
Other-Crew Lounge
|
|
Violation:
Nail polish remover and a shoe shine kit were stored in the drawer with silverware and disposable forks. The items were removed.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
28
|
|
Site:
Other-Liquor Room
|
|
Violation:
A container of champagne glasses was stored directly on the deck.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
28
|
|
Site:
Other-Laundry Store Room
|
|
Violation:
A large gray bin of glasses and large clear bin of yellow plates were stored on the deck.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
31
|
|
Site:
Other-Laundry Store Room
|
|
Violation:
A large gray bin of glasses and large clear bin of yellow plates were stored on the deck next to chemicals.
|
|
Recommendation:
Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
31
|
|
Site:
Other-Crew Lounge
|
|
Violation:
Nail polish remover and a shoe shine kit were stored in the drawer with silverware and disposable forks. The items were removed.
|
|
Recommendation:
Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dry Store
|
|
Violation:
The deckhead panels were not flush with each other, which left gaps exposing the technical areas above.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Upright Refrigerators
|
|
Violation:
There was excessive dust around and on the exposed air conditioning unit filters on the deckhead directly in front of the upright refrigerators.
|
|
Recommendation:
Ensure light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Bar-Lounge Settees
|
|
Violation:
Three boxes of 36 apple juice boxes, multiple bottles of water, four bags of ginger candies, and two mesh bags with greater than 25 packages of coffee each were stored on the soiled deck under the cushion of a settee in the lounge.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Bar-Lounge Neutral Cabinet
|
|
Violation:
Many bottles of beverages and packaged food was stored in the neutral cabinet in the lounge dining area of the bar. There was no top to the cabinet, so the area was exposed to the technical areas of the plenum above.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Training of Integrated Pest Management (IPM) Manager
|
|
Violation:
It was stated that the IPM Manager had IPM training in January 2018, but there was no record of this.
|
|
Recommendation:
Document the training of the pest-control personnel.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP did not state the specific disinfectant products to be used, the concentration, contact time, or CT value for regular operations. The OPRP did not state the specific disinfectant products to be used or the concentration, contact time, or CT value required to be effective against norovirus when the trigger was met to step up outbreak management in response to increased case counts on the vessel.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP contained procedures for notifying passengers and crew members of an outbreak, as well as for notifying embarking passengers that a previous cruise had an outbreak; however, there was no written letter or Captain's announcement available for review during the inspection.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage.
|
|
|
Item No.:
44
|
|
Site:
Potable Water-Distribution System
|
|
Violation:
From 2100 on 19 April to 0830 on 21 April the free halogen residual was below 0.2 ppm and for the majority of this period was 0 ppm. Staff stated that the inclement weather caused suction on the ball on the overboard water tank line, which created a vacuum of the potable water distribution system. There were no records to show what the free halogen residual was in the potable water distribution system. On 24 May from 1250-1530, the free halogen residual was below 0.2 ppm; there were no records to indicate why this happened. On 27 January to 0913 on 31 January the halogen residual was below 0.2 ppm and for the majority of this period as 0 ppm. The ship left dry-dock on 26 January and started a new voyage on 27 January. There were no records to indicate why this happened and it was unknown if the low halogen alarm was activated.
|
|
Recommendation:
Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP-during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|