Item No.:
44
|
|
Site:
Medical-MIDRS Confirmation Report
|
|
Violation:
Crew were unable to present the inspector with a confirmation report for their 24 hour MIDRS report for their 8 April Port of Call in San Diego. The vessel had come from Mexico and there were no passengers onboard. Crew stated they do not submit such reports if sailing without passengers.
|
|
Recommendation:
Ensure the supervisor or person in charge of medical operations related to AGE on the vessel demonstrates to VSP?during inspections and on request?knowledge of medical operations related to AGE, is able to demonstrate this knowledge by compliance with Section 4 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 4 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Records
|
|
Violation:
The far point charts were not initialed from 25 Mar - 11 Apr. Crew were onboard but there were no passengers. From 6-11 Apr, manual samples were also taken, and the documentation was initialed.
|
|
Recommendation:
Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Visual Inspection Results
|
|
Violation:
The last visual inspection of nontestable backflow preventers occurred on 1 May 17 which was overdue for inspection.
|
|
Recommendation:
Inspect backflow prevention devices periodically and replace any failed units.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Reverse Osmosis Mechanical Room
|
|
Violation:
The double check valve with intermediate atmospheric vent (DCIV) backflow prevention device at the connection of the permeate and bunkering lines was not listed on the cross-connection control log.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water Tank Maintenance and Disinfection Records
|
|
Violation:
There was no chlorine residual documented prior to putting the tank back in service for the tank disinfection that concluded on 4 Nov 17.
|
|
Recommendation:
Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service. Document the free halogen residual level.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-400 Deck Machinery Space
|
|
Violation:
There was excessive standing water in the condensate drip tray for the HVAC unit that serviced the dining and lounge areas. The water did not drain properly because the drain line raised higher than the drain connection to the drain tray. There was paper-like debris and a dead fly in the water in the tray.
|
|
Recommendation:
Ensure condensation collection pans are self-draining. Keep air handling units clean.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Spas
|
|
Violation:
No high or low level alarms for pH and halogen were installed for the whirlpool spas. This was written on the previous four inspection reports. There was no documentation that the single, blockable suction fitting cover for the starboard whirlpool spa was certified as an antientrapment cover. This was written on the previous inspection report. There was no drain cover on the port whirlpool spa, but the spa was clearly marked closed for maintenance. There was no secondary antientrapment protection installed on the suction line, such as a safety vacuum release system or automatic pump shut off. The whirlpool spas were household grade and not commercial grade. This was written on the previous inspection report.
|
|
Recommendation:
Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children's pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF. For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system. Ensure the testing of manufactured drain covers is by a nationally or internationally recognized testing laboratory. Ensure the following information is stamped on each manufactured antientrapment drain cover: (1) certification standard and year; (2) type of drain use (single or multiple); (3) maximum flow rate (in gallons or liters per minute); (4) type of fitting (suction outlet); (5) life expectancy of cover; (6) mounting orientation (wall, floor, or both); (7) manufacturer's name or trademark; and (8) model designation. Ensure the design of custom/shipyard constructed (field fabricated) drain covers and suction fittings is fully specified by a registered design professional in accordance with ASME A112.19.8-2007. Ensure the specifications fully address cover/grate loadings, durability, hair, finger and limb entrapment issues, cover/grate secondary layer of protection, related sump design, and features specific to the RWF. Provide a letter from the shipyard for each custom/shipyard constructed (field fabricated) drain cover fitting. At a minimum, ensure the letter specifies the shipyard, name of the vessel, specifications and dimensions of the drain cover, as well as the exact location of the RWF for which it was designed. Ensure the name of and contact information for the registered design professional and signature are on the letter.
|
|
|
Item No.:
*
|
|
Site:
*General Comments-Whirlpool Spas
|
|
Violation:
Crew noted that they have plans to install a commercial grade whirlpool spa on the 400 deck in the fall and will remove the currently-installed whirlpool spas to be in compliance with the VSP Operations Manual. Currently there is no shower or toilet facility on the deck. There was no equipment available for evaluation in a mechanical room. Crew were encouraged to contact VSP for a plan review of the planned construction.
|
|
Recommendation:
Contact VSP@CDC.GOV to request a plan review after plans for the installation of the commercial-grade whirlpool spa are developed. The installation should be in accordance with the 2018 VSP Construction Guidelines, including the installation of equipment in the mechanical room as well as meeting the shower and toilet requirements.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Spas
|
|
Violation:
For the month of March, the majority of the shock halogenations had a stop value lower than 10 ppm, but was checked over 1 hour after the start time. Additionally, there was no specific start and stop time, minutes, or ppm values recorded for the cartridge filter or hair/lint strainer disinfection.
|
|
Recommendation:
Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing. Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures. Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Spas
|
|
Violation:
The data logger used for monitoring the halogen and pH of the whirlpool spas was not tamper-proof and did not store data in a secure database. Staff stated they are aware and are planning on having a compliant system installed in the planned whirlpool spa. This was written on the previous four inspection reports. Staff took manual readings every four hours.
|
|
Recommendation:
Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children's pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF. If an electronic data logger is used in lieu of a chart recorder, ensure it has certified data security features. Conduct manual comparison tests for free halogen residual and pH before opening the RWF to verify calibration. Ensure the analyzer reading is within 0.2 ppm for free halogen and 0.2 for pH. For RWFs open longer than 24 hours, conduct a manual comparison test every 24 hours.
|
|
|
Item No.:
26
|
|
Site:
Galley-Ice Machine
|
|
Violation:
There was a small amount of black debris along the sealant in the upper left area of the ice bin. Additionally, there was a small amount of dark debris at the bottom of the ice chute under the right evaporator.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
21
|
|
Site:
Galley-Preparation Area
|
|
Violation:
Sealant was missing from the juncture between the two preparation countertops opposite the ice bin. The area was difficult to clean and was soiled with greater than a day's accumulation of debris. Crew reported it was on a work order.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-Preparation Area
|
|
Violation:
Sealant was missing from the juncture between the two preparation countertops opposite the ice bin. The area was difficult to clean and was soiled with greater than a day's accumulation of debris. Crew reported it was on a work order.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
24
|
|
Site:
Galley-Preparation Area
|
|
Violation:
Solution in the sanitizer bucket measured 0 ppm. Crew reported that cleaning solution was stored in a bucket labeled for sanitizing solution.
|
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm); (2) An iodine solution with a pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies the solution is effective AND a concentration between 12.5 mg/L (ppm) and 25 mg/L (ppm); (3) A quaternary ammonium compound solution with a concentration as specified in 40 CFR 180.940 Sanitizing Solutions AND as indicated by the manufacturer's use directions included in the labeling. If another solution concentration or temperature of a chlorine, iodine, or quaternary ammonium compound is used, demonstrate to VSP that the solution achieves sanitization and the use of the solution is approved. If a chemical sanitizer other than a chlorine, iodine, or quaternary ammonium compound is used, ensure it is applied in accordance with the manufacturer's use directions included in the labeling. Only store santizing solution in buckets labeled for santizing solution.
|
|
|
Item No.:
13
|
|
Site:
Galley-Sanitizing Solution
|
|
Violation:
Crew were unaware that the contact time required for the multi-quat sanitizer was at least one minute.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment. Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (3) By responding correctly to the inspector's questions as they relate to the specific food operation.
|
|
|
Item No.:
*
|
|
Site:
Galley-Engineer Quarters
|
|
Violation:
The engineer's quarters and office was located directly off the galley. There was no other way to access this space other than walking through the galley.
|
|
Recommendation:
If galley renovations occur, do not locate living quarters directly off the galley. Do no locate offices off the galley, with the exception of offices required for food operations.
|
|
|
Item No.:
38
|
|
Site:
Galley-Cleaning Materials
|
|
Violation:
Cleaning materials such as a wet mop stored in a bucket, brooms, etc were stored together next to the door. The items were stored together and were in an area that appeared to be designated for cleaning supplies; however, they were not in a cleaning locker and the area did not have signage designating it for cleaning materials only. Additionally, cleaning detergents that were not in-use were stored on the deck under the clean end of the ware wash instead of in a designated cleaning materials locker.
|
|
Recommendation:
Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles. Label the locker "CLEANING MATERIALS ONLY." Store maintenance tools such as mops, brooms, and similar items in an orderly manner that facilitates cleaning of the area used for storing the maintenance tools. After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
|
|
|
Item No.:
08
|
|
Site:
Galley-Coffee Machine
|
|
Violation:
The double check valve with immediate atmospheric vent (DCIV) backflow prevention device installed on the coffee machine was not on the cross-connection control log.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
37
|
|
Site:
Galley-Combination Ovens
|
|
Violation:
There was excessive condensation on the deckhead above the in-use combination ovens. There was no exhaust vent in the area. No dripping was noted.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
33
|
|
Site:
Galley-Combination Ovens
|
|
Violation:
There was excessive condensation on the deckhead above the in-use combination ovens. No dripping was noted. Also, there was a large gap in the deckhead around the electrical wires for the combination oven. The gap created a difficult-to-clean area that exposed the area to the plenum above.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
38
|
|
Site:
Galley-Pastry
|
|
Violation:
A personal water bottle was stored in the galley near cleaning chemicals. There was no water fountain available in the galley for crew members to drink during their shift. If there is a galley renovation, a drinking fountain should be installed.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
27
|
|
Site:
Galley-Pastry
|
|
Violation:
Two previously cleaned 18-quart plastic bins were stored with sticker residue on them.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
16
|
|
Site:
Galley-Pastry
|
|
Violation:
A previously-opened carton of cream with a discard date of 11 May was stored in the upright refrigerator. The inspection was conducted on 13 May. The cream was discarded.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food is discarded if not consumed within 7 calendar days from the date of preparation or opening.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck
|
|
Violation:
The deck was vinyl. Crew reported is was installed approximately six months prior.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
16
|
|
Site:
Galley-Time Control
|
|
Violation:
Crew reported that they used time control in the galley, but there was no time control plan posted. Crew had a written plan stored in a binder. There was a hotel tray of cut lettuce in the cold well adjacent to the hot line. The lettuce was uncovered, there was no label to indicate it was on time control, and crew were not actively working in the area. Crew reported the lettuce was on time control, but the hot and cold units were not listed on the time control plan in the Chef's binder. The time control plan did not list any units in the galley. The lettuce measured 42°F by the inspector with a thermometer with an error of accuracy less than 1°F. Crew reported that all periods of time control were less than four hours and that food was discarded at the end of service.
|
|
Recommendation:
If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control. Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
There were no cooling logs for the past 30 days. Crew noted that they do not often cool; rather, food is on time control or immediately delivered for service, and what remains is discarded. There was a plate in the crew refrigerator which contained a fork, fish, lasagna, and salad. There was no cooling log for any of these items. Crew reported the cooling was not monitored.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
There were no cooling logs for the past 30 days. Crew noted that they do not often cool; rather, food is on time control or immediately delivered for service, and what remains is discarded. There was a plate in the crew refrigerator which contained a fork, fish, lasagna, and salad. There was no cooling log for any of these items. Crew reported the cooling was not monitored.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours. Cool potentially hazardous food within 4 hours to 5°C (41°F) or less if prepared from ingredients at ambient temperature.
|
|
|
Item No.:
19
|
|
Site:
Galley-Hot Line Cold Basin
|
|
Violation:
A hotel pan containing lettuce was uncovered. No one was actively working in the area.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
13
|
|
Site:
Galley-Crew Refrigerator
|
|
Violation:
There were no cooling logs for the past 30 days. Crew noted that they do not often cool; rather, food is on time control or immediately delivered for service, and what remains is discarded. There was a plate in the crew refrigerator which contained a fork, fish, lasagna, and salad. It was unclear if the food had been partially eaten. There was no cooling log for this. Crew reported the cooling was not monitored.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines. Ensure the supervisor or person in charge of food operations on the vessel monitors that: (7) Employees are using proper methods to rapidly cool potentially hazardous foods that are not held hot or are not for consumption within 4 hours.
|
|
|
Item No.:
22
|
|
Site:
Galley-Hot Line
|
|
Violation:
There was excessive debris in the sanitizing bucket near the hot line.
|
|
Recommendation:
Ensure the wash, rinse, and sanitize solutions are maintained clean.
|
|
|
Item No.:
08
|
|
Site:
Galley-Warewash
|
|
Violation:
There was no backflow prevention device for the pre-rinse hose. There was a spring installed, but it was worn and failing. There was no air gap above the flood rim of the sink.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (28) any other connection to the potable water system where contamination or backflow can occur.
|
|
|
Item No.:
19
|
|
Site:
Galley-Walk-In Freezer
|
|
Violation:
A stack of four boxes of ground beef and a box of French fries were stored directly on the deck.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Wine Cage
|
|
Violation:
There was an extremely large gap around the mechanical protrusion at the far corner of the wine cage which exposed the void space.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Wine Cage
|
|
Violation:
Packages of soda were stored directly on the deck.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
26
|
|
Site:
Bar-Beer Taps
|
|
Violation:
An excessive amount of dark debris was on the food-contact surface inside two beer taps. The area was not open for passenger service at the time of inspection.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
24
|
|
Site:
Bar-Sanitizing Bucket
|
|
Violation:
The solution measured 150 ppm, but crew reported that they use 200-400ppm of quaternary ammonia.
|
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (3) A quaternary ammonium compound solution with a concentration as specified in 40 CFR 180.940 Sanitizing Solutions AND as indicated by the manufacturer's use directions included in the labeling. If another solution concentration or temperature of a chlorine, iodine, or quaternary ammonium compound is used, demonstrate to VSP that the solution achieves sanitization and the use of the solution is approved.
|
|
|
Item No.:
33
|
|
Site:
Bar-
|
|
Violation:
There were openings to the technical space near the deck under the speed well and the adjacent area. These areas were difficult to clean, and a cork and measuring spoon was found on the deck. The area was not open and crew were not present in the bar when the inspector approached the area for inspection.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
01
|
|
Site:
Medical-MIDRS Confirmation Report
|
|
Violation:
Crew were unable to present the inspector with a confirmation report for their 24 hour MIDRS report for their 8 April Port of Call in San Diego. The vessel had come from Mexico and there were no passengers onboard. Crew stated they do not submit such reports if sailing without passengers.
|
|
Recommendation:
Ensure the master, medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port submits at least one standardized AGE report based on the number of reportable cases in the AGE log to VSP no less than 24 hours-but not more than 36 hours-before the vessel's expected arrival at the U.S. port. Ensure MIDRS reports are submitted when sailing from a foreign port of call to a US port of call regardless if there are passengers onboard.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Log
|
|
Violation:
Crew were unable to present the inspector with the AGE log for 24-31 Mar cruise.
|
|
Recommendation:
Maintain a daily, standardized AGE surveillance log for each cruise by the master of the vessel, the medical staff, or other designated staff. Maintain the following records on board for 12 months and make them available for review by VSP during inspections and outbreak investigations: (1) medical log/record; (2) AGE surveillance log; (3) 2-hour self-administered questionnaires; (4) interviews with cabin mates and immediate contacts of crew members with AGE [initial, 24-, and 48-hour]; (5) documentation of the 3-day assessment of crew members with AGE symptoms before joining the vessel; (6) documentation of the date and time of last symptom and clearance to return to work for food and nonfood employees; and (7) documentation of the date and time of verbal interviews with asymptomatic cabin mates and immediate contacts of symptomatic crew.
|
|
|
Item No.:
08
|
|
Site:
Bar-Soda
|
|
Violation:
The Watts 9BD M1 backflow preventer that was installed on the main potable water line for the soda gun was not sufficient for the location it was installed. The installation specifications are to install it between the pump and carbonator tank. An ASSE 1022 type B backflow preventer was installed between the carbonator tank and the pump, and was an acceptable installation. An appropriate continuous pressure backflow preventer should be installed on the potable water line.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment;
|
|
|
Item No.:
08
|
|
Site:
Bar-Coffee Machines
|
|
Violation:
Crew were unable to identify a backflow preventer for the two coffee machines and stated there was not one installed.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment;
|
|
|
Item No.:
38
|
|
Site:
Bar-
|
|
Violation:
Cleaning materials for the bar were stored on the deck under the speedwell and in the open area under the utility sink. There was no designated cleaning locker.
|
|
Recommendation:
Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles. Label the locker "CLEANING MATERIALS ONLY."
|
|
|
Item No.:
16
|
|
Site:
Bar-Undercounter Refrigerator
|
|
Violation:
An open carton of milk on temperature control was measured 45°F by the inspector with a sensitive tip thermometer. Crew measured a similar temperature. It was discarded.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
|
|
|
Item No.:
17
|
|
Site:
Bar-Undercounter Refrigerator
|
|
Violation:
Bloody Mary mix in the undercounter refrigerator was made with tomato juice at room temperature but was not on the cooling log. It was made less than four hours prior to the inspection and had cooled below 41°F.
|
|
Recommendation:
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
38
|
|
Site:
Bar-Outdoor Sun Bar
|
|
Violation:
The outdoor portable Sun Bar was extremely soiled from being stored outside. There was an empty soda can and bottles of a sticky substance that had opened into a plastic bin. There was a cleaning brush and wood stored here. Crew reported it had not been used in at least four years and they wished to discard it.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Log
|
|
Violation:
A column listed passenger/guest with answers of Y or N instead of listing Passengers/Crew.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person's name; (5) person's age; (6) person's sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
|
Item No.:
02
|
|
Site:
Medical-Onboarding Crew Assessment
|
|
Violation:
The 1B Form for the Conditional Employee or Food Employee Reporting Agreement states 'I agree to report to the person in charge: any onset of the following symptoms, either while at work or outside of work, including the date of onsets 1. Diarrhea 2. Vomiting...' but does specifically state that crew members must report such symptoms including 72 hours prior to coming onboard the vessel.
|
|
Recommendation:
Ensure the reportable cases include crew members with a symptom onset time of up to 3 days before boarding the vessel. Maintain documentation of the 3-day assessment for each crew member with symptoms on the vessel for review during inspections and retain this documentation for 12 months. Maintain the following records on board for 12 months and make them available for review by VSP during inspections and outbreak investigations: (5) documentation of the 3-day assessment of crew members with AGE symptoms before joining the vessel;
|
|
|
Item No.:
02
|
|
Site:
Medical-Bacterial Specimen Collection Kit
|
|
Violation:
The clinical specimen collection containers for bacterial agents were expired in Dec 2016. Crew were unable to provide at least ten that were not expired.
|
|
Recommendation:
Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each), as well as a shipping container that meets the latest shipping requirements of the International Air Transport Association (IATA) and U.S. Department of Transportation for Biological Substances, Category B designated shipments (or higher). Ensure the vessel maintains the appropriate labels and markings required for shipping Biological Substances, Category B shipments. Ensure the vessel maintains appropriate refrigerant materials to keep clinical specimens cool. (see Annex 13.4 of the VSP 2011 Operations Manual.)
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Weekly Garbage Inspection
|
|
Violation:
The Integrated Pest Management (IPM) Plan included a provision for weekly inspections of the garbage area; however, there were no logs that documented this.
|
|
Recommendation:
Inspect all food areas at a frequency that can quickly detect the evidence of pests, harborage conditions, cleanliness, and protection of outer openings. In nonfood areas, give reasonable care to conduct inspections for the presence of insects, rodents, and other pests. Inspect the garbage handling areas of the vessel at least weekly for the presence of insects, rodents, and other pests. Maintain the results of these inspections in a log.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP stated that crew would notify passengers of an outbreak, including symptoms of gastrointestinal illness. However, the suggested announcement text was not specific about the outbreak onboard and did not effectively communicate to passengers and crew about the outbreak or symptoms. The GI Outbreak during an outbreak text did not inform the passengers of what symptoms to look for. It also implied that sick individuals should increase handwashing, but did not state all passengers should. Neither text for during or after the outbreak stated specifically that there was an outbreak of gastrointestinal illness onboard the vessel. The text for an outbreak suggested that there was a stomach bug in the area or region but did not specify there were elevated levels of illness onboard the ship.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage. Notification to passengers and crew regarding a current outbreak or an outbreak on a previous cruise should at a minimum specify that there was an outbreak of gastrointestinal illness (GI), include specific symptoms of GI illness, and statement regarding handwashing.
|
|
|
Item No.:
44
|
|
Site:
Recreational Water Facilities-Whirlpool Spas
|
|
Violation:
The whirlpools were not operated in accordance with the 2011 VSP Operations manual including: 1) The data logger did not have security features; 2) There was no antientrapment drain cover documentation; 3) There were multiple instances where the stop value of shock halogenation was less than 10; 4) There was no specific values listed or time for the hair/ lint strainer and cartridge filter disinfection; and 5) There was no high and low halogen or pH level alarms.
|
|
Recommendation:
Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP-during inspections and on request - knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|
|
Item No.:
04
|
|
Site:
Potable Water-Far Point Records
|
|
Violation:
From 0900-1830 on 23 MAR, the far point chart documented that the chlorine was above 5ppm for extended periods of time. There was no alarm log or alarm documented on the chart, but crew reported there is a working alarm. There were no manual in-range values recorded. The far point chart noted that the vessel was bunkering in La Paz. Crew stated that they can adjust the chlorine and pH while bunkering into the tank, but are not able to adjust the levels of chlorine and pH once the potable water leaves the tank and enters the distribution system. The bunkering records for the same day indicated that the chlorine in the water was less than 5ppm during bunkering. The vessel did not enter the US until 8 APR.
|
|
Recommendation:
Provide continuous halogenation of the potable water system using halogenation injection equipment and maintain a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
|
|