Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: AIDAVITA Cruise Line: Aida Cruises Inspection Date: 06/25/2018 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Potable Water-Potable Water Distribution Disinfection Log
Violation: The final free halogen residual for all the potable water system maintenance conducted from 9 January 2017 to 3 March 2018 was recorded at 0.52 ppm on the log. There were more than 10 different maintenance events recorded on the log with a final free halogen level of 0.52 ppm.
Recommendation: Ensure the final free halogen residual is tested and recorded after each pipe disinfection.
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log and Food/Beverage Questionnaire
Violation: The AGE log and food/beverage questionnaires were not in compliance with the 2018 VSP Operations Manual.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP. Distribute questionnaires detailing activities and meal locations for the 72 hours before illness onset to all passengers and crew members who are AGE CASES. Ensure that the self-administered questionnaires contain all of the data elements that appear in the questionnaire found in Annex 13.2.2. Ensure that completed questionnaires are maintained with the AGE surveillance log.
Item No.: 08
Site: Potable Water-Evaporator #2 Backflow Device
Violation: There was no air gap between the vent and the catch/drainage pan beneath this device. The vent had an additional piece of plastic installed which allowed for the unit to drain but eliminated an air gap between the vent and the floor rim level of the catch/drainage pan. The end of the drain from the catch/drainage pan was not visible.
Recommendation: Provide an air gap for the atmospheric vent of all backflow prevention devices.
Item No.: 08
Site: Bar-AIDA Bar
Violation: The atmospheric vents on the backflow prevention device installed on the water line for the counter-installed beer glass wash sprays by the beer taps were blocked with debris.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 08
Site: Provisions-Wine Tank Storeroom
Violation: The atmospheric vents on the backflow prevention device before the carbonator for the wine dispenser were blocked with black debris.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 10
Site: Recreational Water Facilities-Hair and Lint Strainer Logs
Violation: The hair and lint strainers and housing were not being disinfected on a weekly basis. There were multiple instances where two or three weeks passed before disinfection was documented for all recreational water facilities.
Recommendation: Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures. Ensure that if there is not a hair and lint strainer but there is a filter before the pump, this filter must be cleaned, rinsed, and disinfected weekly.
Item No.: 18
Site: Galley-Deck 8 Selection Restaurant
Violation: A hotel pan of cold smoked salmon was stored above a hotel pan of various cheese inside reach-in refrigerator #8
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another.
Item No.: 19
Site: Buffet-Calypso Overflow Beverage Station
Violation: One of the activation levers on a soda dispensing nozzle was shorter than the other levers and would contact the lip-contact portion of a drinking cup. Passengers were able to refill their glasses at this soda station.
Recommendation: For second portions and refills, ensure (1) Except for refilling a consumer's drinking cup or container without contact between the pouring utensil and the lip-contact area of the drinking cup or container, food employees do not use tableware - including single-service articles - soiled by the consumer, to provide second portions or refills. (2) Self-service consumers are not allowed to use soiled tableware, including single-service articles, to obtain additional food from the display and serving equipment except drinking cups if refilling is a contamination-free process.
Item No.: 20
Site: Buffet-Calypso Beverage Station
Violation: The milk dispensing tube from the bulk milk dispenser was longer than 50 mm (2 inches).
Recommendation: Cut bulk milk dispensing tubes 45 degrees on the diagonal, leaving no more than 25 mm (1 inch) protruding from the chilled dispensing head.
Item No.: 21
Site: Buffet-Calypso Starboard
Violation: The removable countertop section above undercounter refrigerator #14 was chipped in several locations around the edges.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Pool Grill
Violation: The drip tray housing under the left flat grill was loose and hanging from the bottom the grill, which created a difficult to clean area. Also, the opening around both grease chutes in the drip tray were not profiled.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Pot Wash
Violation: Three different cutting boards on the clean storage rack were missing the rubber feet on the bottom to keep the board in place during use. Each missing rubber foot exposed a difficult to clean recessed hole in the bottom of the cutting board.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Bar-AIDA Bar
Violation: Several coffee cups were stacked and small plates were leaning together in two separate dish racks on the clean landing of the hood-type dishwash machine. Staff stated that the two racks of plates and coffee cups had been washed recently. The position of the stacked coffee cups and leaning plates did not allow for proper cleaning and sanitizing.
Recommendation: Ensure soiled items to be cleaned in a warewashing machine are loaded into racks, trays, or baskets or onto conveyors in a position that (1) exposes the items to the unobstructed spray from all cycles; (2) allows the items to drain.
Item No.: 22
Site: Galley-Deck 8 Warewash
Violation: Three glass drinking cups were sent though the rack-type glasswash machine upright on a dish rack. The drinking glasses were filled with water after going through the machine.
Recommendation: Ensure soiled items to be cleaned in a warewashing machine are loaded into racks, trays, or baskets or onto conveyors in a position that (1) exposes the items to the unobstructed spray from all cycles; (2) allows the items to drain.
Item No.: 27
Site: Galley-Pool Grill
Violation: The bottom of the left flat grill around the loose drip tray housing was soiled with grease residue.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Deck 8 Walk-In Freezer #8
Violation: A light layer of frozen condensation had accumulated on the deckhead, bulkheads, and several storage shelves inside the walk-in freezer.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Calypso
Violation: An excessive amount of water was pooled on the deck around the coffee machines and in the corridor leading to the pizzeria. The source of the water could not be determined.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Galley-Deck 8 Walk-In Freezer #8
Violation: A light layer of frozen condensation had accumulated on the deckhead, bulkheads, and several storage shelves inside the walk-in freezer.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 36
Site: Galley-Calypso
Violation: The light bulb on the deckhead behind the ice machine was burnt out, resulting in a light intensity less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Buffet-Calypso Overflow Waiter Station
Violation: The light intensity on both ends of the clean and soiled waiter station could not be raised to at least 220 lux for cleaning
Recommendation: In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program