Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Log
|
|
Violation:
From mid-February 2018 to13 June 2018, the underlying illness conditions column was left blank. The inspector talked to staff about using 'none' or 'N/A' if there are no conditions to report.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
|
Item No.:
02
|
|
Site:
Medical-Medications Sold or Dispensed
|
|
Violation:
It was noticed by the inspector that in a medical history form for a symptomatic crew member dated 27 March 2018, antidiarrheal medication was written in the history remark section. The inspector asked staff who distributed the an antidiarrheal medication . Staff stated that some of the crew members have their own supply. The inspector discussed with staff that this practice is not acceptable for passengers or crew.
|
|
Recommendation:
Ensure antidiarrheal medications are not sold or dispensed to passengers or crew except by designated medical staff.
|
|
|
Item No.:
05
|
|
Site:
Potable Water-Distant Point Cart Recorder
|
|
Violation:
Three samples were taken at the distant point analyzer by the inspector. The readings were 1.60 ppm, 1.61 ppm, and 1.56 ppm. The analyzer chart recorded residual levels of 2.09 ppm, 2.40 ppm, and 1.86 ppm respectively. The average margin of error for all three samples was 0.53 ppm.
|
|
Recommendation:
Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Annual Testing for Backflow Prevention Devices
|
|
Violation:
Backflow devices for the Fire, Reverse Osmosis, Hi-Fog, and Deck Washing systems were last checked on 6 June, 28 May, 9 June, and 9 June respectively. The inspection date was 13 June. These devices need to be checked annually.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Garbage Room
|
|
Violation:
As the inspector entered the garbage room, a hose with a pressurized nozzle was hanging on the bulkhead. When the inspector asked staff where the water supply was for the hose, staff explained that the hose was screwed onto the hand wash sink spigot. The inspector explained that this was not a good practice for hygiene purposes, and that there was no backflow device to protect the potable water supply.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (1) RWFs; (2) decorative water features/fountains; (3) cabin shower hoses, toilets, whirlpool tubs, and similar facilities; (4) photographic laboratory developing machines and utility sinks; (5) beauty and barber shop spray-rinse hoses; (6) spa steam generators where essential oils can be added; (7) hose-bib connections; (8) garbage grinders and food waste systems; (9) automatic galley hood washing systems; (10) food service equipment; (11) mechanical warewashing machines; (12) detergent dispensers; (13) hospital and laundry equipment; (14) air conditioning expansion tanks; (15) boiler feed water tanks; (16) fire system; (17) public toilets, urinals, and shower hoses; (18) potable water, bilge, and pumps that require priming; (19) freshwater or saltwater ballast systems; (20) international fire and fire sprinkler water connections (install a reduced pressure assembly); (21) the potable water supply to automatic window washing systems that can be used with chemicals or chemical mix tanks; (22) water softeners for nonpotable fresh water; (23) water softener and mineralizer drain lines, including backwash drain lines (install an air gap or a reduced pressure assembly); (24) high saline discharge line from evaporators (install an air gap or a reduced pressure assembly); (25) chemical tanks; (26) other connections between the potable water system and a nonpotable water system, such as the gray water system, laundry system, or technical water system (install an air gap or a reduced pressure assembly); (27) black water or combined gray water/black water systems (install an air gap); (28) Hi-Fog or similar suppression systems which are connected to potable water tanks; (29) any other connection to the potable water system where contamination or backflow can occur.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Atlantic
|
|
Violation:
Previously cleaned plates were stored correctly on a serving table what was to be used for food service during embarkation. The food was to be served at that table in a carpeted area of the dining room. The table was moved to a more easily cleanable deck area.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
33
|
|
Site:
Galley-Blast Chiller
|
|
Violation:
The deck under the blast chiller contained an accumulation of food debris and trash beyond a day's accumulation.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
38
|
|
Site:
Galley-Chemical Storage Locker
|
|
Violation:
A soiled wet mop was stored inside the mop bucket not allowing it to air dry in this locker.
|
|
Recommendation:
After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
One live house fly was observed in the buffet area in the mess. The area was not open and no food or crew were present.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
44
|
|
Site:
Medical-Medical Procedure Knowledge
|
|
Violation:
As the inspector talked through the ships medical procedures, staff was unsure about the difference of food and non-food worker isolation periods. Additionally, when the inspector asked about the an antidiarrheal medication being in a crew member's cabins, staff was unsure if this was allowed.
|
|
Recommendation:
Ensure the supervisor or person in charge of medical operations related to AGE on the vessel demonstrates to VSP?during inspections and on request?knowledge of medical operations related to AGE, is able to demonstrate this knowledge by compliance with Section 4 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 4 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|