|
Item No.:
02
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
Violation:
The AGE log was not updated to meet the requirements in the 2018 VSP Operations Manual. There was a column for passenger seating and there were no columns for date and time of last symptom.
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person's name; (5) person's age; (6) person's sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
Item No.:
02
|
Site:
Medical-72-Hour Activities Questionnaire
|
Violation:
The 72-hour activities questionnaire for AGE cases was not updated to include whether the case was a passenger or crew member. This was a new requirement in the 2018 Operations Manual.
|
Recommendation:
Distribute questionnaires detailing activities and meal locations for the 72 hours before illness onset to all passengers and crew members who are AGE CASES. Ensure that the self-administered questionnaires contain all of the data elements that appear in the questionnaire found in Annex 13.2.2. Ensure that completed questionnaires are maintained with the AGE surveillance log.
|
|
Item No.:
16
|
Site:
Galley-Cold Pantry
|
Violation:
A hotel pan of chicken quesadillas was stored in an undercounter refrigerator with 7-day discard label indicating a discard date of 2 September (prepared on 27 August). However, after reviewing the cooling log it was determined the chicken was originally cooked and cooled on 24 August which meant the discard date was 30 August. The 7-day discard label was revised to indicate 30 August as the discard date.
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. Ensure refrigerated, potentially hazardous, ready-to-eat food ingredients or a portion of a refrigerated, potentially hazardous, ready-to-eat food that is subsequently combined with additional ingredients or portions of food retains the date marking of the earliest or first-prepared ingredient.
|
|
Item No.:
20
|
Site:
Galley-Forward Hot Line
|
Violation:
The flat grill on the starboard end of the back service line had three cracks around the perimeter of the grill.
|
Recommendation:
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
Item No.:
21
|
Site:
Other-Bonsai
|
Violation:
The gasket on the rice warmer was loose and peeling at the back. A technician was called immediately.
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
Item No.:
21
|
Site:
Galley-Steakhouse
|
Violation:
The induction stove top was cracked. Staff stated a work order had been submitted.
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
Item No.:
22
|
Site:
Galley-Warewash
|
Violation:
The curtain between the wash compartment and rinse compartment of the conveyor dishwash machine was soiled with food debris between the curtain flaps.
|
Recommendation:
Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination and accumulation of excessive debris, and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
|
|
Item No.:
22
|
Site:
Galley-Warewash
|
Violation:
The second spray nozzle from the right on the upper final rinse manifold in the rack-type glass wash machine was not producing water during operation.
|
Recommendation:
Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine's data plate and other manufacturer's instructions. Ensure a warewashing machine's conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer's specifications.
|
|
Item No.:
22
|
Site:
Galley-Aft Warewash
|
Violation:
At least six spray nozzles between wash tank 1 and 2 of the conveyor dishwash machine were clogged with food debris during operation.
|
Recommendation:
Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination and accumulation of excessive debris, and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
|
|
Item No.:
22
|
Site:
Galley-Aft Warewash
|
Violation:
The far left spray nozzle on the upper auxiliary rinse manifold of the rack-type glass wash machine was not producing water during operation.
|
Recommendation:
Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine's data plate and other manufacturer's instructions. Ensure a warewashing machine's conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer's specifications.
|
|
Item No.:
22
|
Site:
Galley-Potwash
|
Violation:
The first three curtains inside the mechanical potwash machine were warped, torn, and in poor repair. Also, the curtain before wash tank compartment was soiled with debris between the curtain flaps.
|
Recommendation:
Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination and accumulation of excessive debris, and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used). Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine's data plate and other manufacturer's instructions. Ensure a warewashing machine's conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer's specifications.
|
|
Item No.:
25
|
Site:
Galley-Pasta Bella
|
Violation:
Three employee's chef's towels were wet to the touch during operation. These chef's towels were immediately replaced.
|
Recommendation:
Restrict wiping cloths to the following: (1) Cloths used for wiping food spills are used for no other purpose; (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment; (3) Dry or wet cloths used with raw animal foods are kept separate from cloths used for other purposes. Wet cloths used with raw animal foods must be kept in a separate sanitizing solution; (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
|
|
Item No.:
25
|
Site:
Buffet-Blue Iguana
|
Violation:
One crew member's chef towel was wet to the touch. The crew member's chef towel was replaced.
|
Recommendation:
Restrict wiping cloths to the following: (1) Cloths used for wiping food spills are used for no other purpose; (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment; (3) Dry or wet cloths used with raw animal foods are kept separate from cloths used for other purposes. Wet cloths used with raw animal foods must be kept in a separate sanitizing solution; (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
|
|
Item No.:
27
|
Site:
Buffet-Lido Deli
|
Violation:
The bread display shelves on the starboard side of the buffet counter was soiled with dust and debris.
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
Item No.:
28
|
Site:
Galley-Aft Buffet
|
Violation:
Two stacks of black buffet service containers and bowls were stored on the bulkhead shelf upright and uncovered.
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
Item No.:
33
|
Site:
Buffet-Lido Deli
|
Violation:
The bulkhead to the right of the port side bread display shelf had sticky residue in several locations.
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
Item No.:
33
|
Site:
Preparation Room-
|
Violation:
The bulkhead/deckhead corner above the dry storage rack had a hole.
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
Item No.:
33
|
Site:
Buffet-Staff Mess
|
Violation:
A milk and creamer pitcher were set-up for self-service on a table with a carpeted deck. The two pitchers were relocated to the beverage station.
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
Item No.:
33
|
Site:
Room Service-
|
Violation:
Water was dripping from a deckhead light fixture between the warewash area and beverage line. A plumber had already been called and arrived while the inspection team was still in the area.
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
Item No.:
36
|
Site:
Galley-Bakery
|
Violation:
The light cover for the right light inside the top compartment of the deck oven was missing.
|
Recommendation:
Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
|
|
Item No.:
36
|
Site:
Buffet-Lido Deli
|
Violation:
The light intensity in front of the bread display shelf on the port side back preparation counter was less than 220 lux.
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
Item No.:
37
|
Site:
Galley-Warewash
|
Violation:
A significant amount of steam was escaping from the exhaust hood above the soiled end of the conveyor dishwash machine. An employee was constantly wiping the deckhead and bulkhead to clear away the condensation.
|
Recommendation:
Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
|
|
Item No.:
39
|
Site:
Preparation Room-
|
Violation:
Two live drain flies were observed by the dry storage rack.
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|