Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: MS Hamburg Cruise Line: Hamburg Cruise SA Inspection Date: 09/29/2018 Inspection Score: 91
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log / Food and Beverage Questionnaire
Violation: The AGE log and food and beverage questionnaire used by the medical center were not updated and in compliance with the 2018 VSP Operations Manual.
Recommendation: Ensure the AGE surveillance log includes a header containing the following information about the voyage: (1) Vessel name; (2) Voyage number; (3) Date from; (4) Date to; (5) Total number of passengers; (6) Reportable total number of passengers ill; (7) Total number of crew; (8) Reportable total number of crew ill. Total number of passengers and total number of crew must be the totals at the beginning of the voyage (i.e., totals on "date from"). Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Patient ID; (2) Date of the first medical visit or report to staff of illness; (3) time of the first medical visit or report to staff of illness; (4) person's last name; (5) person's first name; (6) person's age; (7) person's sex; (8) designation as passenger or crew member; (9) cabin number; (10) crew member position or job on the vessel, if applicable; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24 hour period; (b) bloody stools (yes/no); (c) number of episodes of vomiting in a 24 hour period; (d) fever (yes/no); (e) abdominal cramps (yes/no); (f) headaches (yes/no); (g) myalgia (yes/no); (14) date of last symptom; (15) time of last symptom; (16) entry (yes/no) for whether a specimen was requested; (17) entry (yes/no) for whether a specimen was received; (18) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (19) entry (yes/no) for whether this was a reportable case; (20) presence of underlying medical conditions that may affect interpretation of AGE. If none, write "none," "not applicable," "N/A," or similar wording. Comments may also be added to the log in this column after the information about underlying illness. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP. Distribute questionnaires detailing activities and meal locations for the 72 hours before illness onset to all passengers and crew members who are AGE CASES. Ensure that the self-administered questionnaires contain all of the data elements that appear in the questionnaire found in Annex 13.2.2. Ensure that completed questionnaires are maintained with the AGE surveillance log.
Item No.: 06
Site: Potable Water-Microbiologic Monitoring
Violation: Medical staff in charge of testing for E. coli were not following the instructions on the 18-hour test kit that they were using. The instructions state that the water must be heated in a water bath prior to placing into the incubator.
Recommendation: If water samples are collected and analyzed by the vessel for the presence of E. coli, analyze the samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Ensure test kits, incubators, and associated equipment are operated and maintained in accordance with the manufacturers' specifications.
Item No.: 08
Site: Potable Water-Evapoators
Violation: Two new reduced pressure backflow devices were install on the high salinity overboard discharge line of both evaporators in July 2018 but were not included on the cross connection control log. Also, the devices were not tested after installation.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections. Retain the visual inspection and/or test results for backflow prevention devices and air gaps for at least 12 months and ensure they are available for review during inspections.
Item No.: 08
Site: Potable Water-Production/Bunker Station
Violation: The sample water leaving the analyzer was discharged into a collection drum which in turn was drained to the gray water tank. The tube from the sample line was below the flood rim of the collection drum. Also, this air gap was not on the cross connection control log.
Recommendation: Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch). Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 08
Site: Galley-Hot Galley
Violation: No backflow prevention device was installed on the water supply line to the deck-mounted combination oven.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment.
Item No.: 09
Site: Recreational Water Facilities-Pool Supply Water
Violation: After the potable water in the supply line to the swimming pool passed through the reduced pressure backflow assembly, the water could be directed either to technical (laundry) or the swimming pool. No backflow prevention device was installed to prevent technical water from supplying the swimming pool.
Recommendation: Ensure the water source for all RWFs is potable water or seawater.
Item No.: 10
Site: Recreational Water Facilities-Swimming Pool
Violation: Staff stated that they did not take manual samples from the swimming pool and compared it to the analyzer sample in the pump room. This is a new requirement to the 2018 VSP Manual.
Recommendation: Ensure manual samples from the RWF tub are compared to the analyzer samples in the pump (mechanical) room to assess potential water quality differences in the RWF. Obtain samples from a location with the following qualities: 1) At least 18 inches (45.7 cm) below the surface of the water, and 2) A water depth of between three to four feet (91.4 cm to 1.2 m) when available, and 3) A location between water inlets.
Item No.: 13
Site: Galley-Cooling Logs
Violation: When questioned about the cooling process by the inspector, galley staff stated that potentially hazardous foods can be cooled as long as the initial internal temperature is above 55°C.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases that are transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of potentially hazardous food, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control points in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual.
Item No.: 13
Site: Buffet-Main Dining Room
Violation: Crew members did not know if the undercounter refrigerators on the buffet line operated as time or temperature control units. Crew initially told the inspector that these refrigerators were on temperature control but the refrigerators were also listed as time control units on the posted time control plan.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases that are transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of potentially hazardous food, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control points in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual.
Item No.: 16
Site: Buffet-Main Dining Room
Violation: Dozens of individual butter packets stored in undercounter refrigerator 49 and 50 below the cold buffet had internal temperatures ranging from 47°F to 50°F when measured by the inspector. Crew initially told the inspector that these refrigerators were on temperature control but the refrigerators were also listed as time control units on the posted time control plan. There was no time control service period occurring at the buffet during the inspection. All the butter packets were discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 16
Site: Galley-Cooling Logs
Violation: The initial internal temperature of several potentially hazardous food items cooled within the previous week was below 57°C (135°F) at the start of the cooling process. Bavarian cream was cooled on 28 September 2018 with an initial internal temperature of 55°C. Vanilla sauce and rice pudding were both cooled on 27 September 2018 with an initial temperature of 55°C. Mango soup was cooled on 27 September 2018 with an initial internal temperature of 54°C. Grilled pineapple cooled on 28 September 2018 with an initial internal temperature of 55°C. Roast beef was cooled on 27 September 2018 with an initial internal temperature of 56°C. Roast pork was cooled on 26 September 2018 and 25 September 2018 with an initial internal temperature of 56°C. Melon soup was cooled on 25 September 2018 with an initial internal temperature of 54°C. Mix berry flan was cooled on 25 September 2018 with an initial internal temperature of 54°C. Roast beef was cooled on 24 September 2018 with an initial internal temperature of 56°C. Chicken galantine was cooled on 24 September 2018 with an initial internal temperature of 55°C.
Recommendation: Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
Item No.: 19
Site: Dining Room-Port Wine Cellar
Violation: The paper towel dispenser for the handwash sink was installed on the adjacent bulkhead above pallet of bottled water. Water from the user's hands would drip onto the stored bottle water as he or she reached for a paper towel.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; and (6) At least 150 millimeters (6 inches) above the deck on shelving racks.
Item No.: 19
Site: Dining Room-Locker 3019
Violation: Food items, such as individual packets of jam and ketchup, were stored in this locker that was not properly designed for food storage. The deckhead was open and had exposed wires and cables and half of the bulkheads were soft and difficult to clean. The deck/bulkhead juncture around the room was also not coved
Recommendation: Do not store foods: (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
Item No.: 21
Site: Buffet-Main Dining Room
Violation: The counter top in the center of the cold buffet had difficult-to-clean seams around the perimeter.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Palm Garden
Violation: There was a gap around the opening of the grease chute under the flat grill.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Galley-Pot Wash
Violation: At least six spray nozzles between the upper and lower final rinse manifolds inside the hood-type potwash machine were clogged with food debris during operation.
Recommendation: Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine's data plate and other manufacturer's instructions. Ensure a warewashing machine's conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer's specifications.
Item No.: 22
Site: Galley-Warewash
Violation: The far right spray nozzle on the auxiliary rinse manifold of the rack-type dishwash machine was producing an ineffective spray pattern.
Recommendation: Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine's data plate and other manufacturer's instructions. Ensure a warewashing machine's conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer's specifications.
Item No.: 26
Site: Galley-Palm Garden
Violation: Three previously cleaned white food display trays stored on the clean storage racks were soiled with debris. Also, two previously cleaned frying pans stored on the top shelf inside the storeroom off the warewash areas were soiled.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-Cold Pantry
Violation: Three previously cleaned hotel pans were stored soiled on the preparation counter.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Galley-Food Lift
Violation: The left side of the food elevator was soiled with debris. The deck juncture of the left side was not coved.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Dining Room-Starboard Coffee Station
Violation: The technical compartment under the coffee station was soiled with more than a day's worth accumulation of dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Dining Room-Locker 3019
Violation: Single-use coffee filters were stored in this locker that was not properly designed for food equipment storage. The deckhead was open and had exposed wires and cables and half of the bulkheads were soft and difficult to clean. The deck/bulkhead juncture around the room was also not coved
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck unless in packages on pallets, skids, or racks, which may be 127 millimeters (5 inches).
Item No.: 28
Site: Galley-Cold Pantry
Violation: A total of 4 stacks of previously cleaned hotel pans in two different locations in the cold pantry were stacked wet.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 29
Site: Galley-Cold Pantry
Violation: The water temperature of the handwash station by the clean storage shelf was measured at 130°F. The water temperature could not be adjusted by the user and the area was in operation.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 29
Site: Galley-3-Sink Handwash Station
Violation: The water temperature at all three handwash sinks opposite the soiled drop-off of the warewash was measured between 122°F and 128°F. The water temperature could not be adjusted by the user and the galley was in operation.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 33
Site: Galley-Deck
Violation: The deck throughout the galley was in poor repair. Grouting was either missing or recessed between a significant portion of the deck tiles throughout the galley, especially around the scuppers in the hot galley, pot wash, and warewash. Standing water was present in several locations were the grouting was wither missing or recessed. Several of the deck/bulkhead junctures around the galley were not coved. Soft silicone was used for coving on at the deck juncture to the right of the blast chiller.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Dining Room-Locker 3019
Violation: Food items, such as individual packets of jam and ketchup, and single-use coffee filters were stored in this locker that was not properly designed for food storage. The deckhead was open and had exposed wires and cables and half of the bulkheads were soft and difficult to clean. The deck/bulkhead juncture around the room was also not coved
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 33
Site: Galley-Food Lift
Violation: The left side of the food elevator was soiled with debris. Also, the deck juncture of the left side was not coved.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Buffet-Palm Garden - Coffee Station
Violation: The deck in front of the coffee station was made of teak wood and was stained in multiple locations. Also, the cabinet/deck juncture was not coved.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 39
Site: Buffet-Palm Garden - Coffee Station
Violation: At least eight ants were observed on the deck in the left corner of the coffee station. This was on an open deck.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Cold Pantry
Violation: One drain fly was observed during operation.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Palm Garden
Violation: One large house fly was observed in the warewash area and one drain fly was in the storage locker.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Warewash
Violation: One drain fly was observed by the warewash machine.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Pot Wash
Violation: At least three drain flies were observed in the potwash area during operation.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 40
Site: Integrated Pest Management-Rat Guards
Violation: The rat guards in place on the forward and aft mooring lines did not fully encircle the mooring line. Also, at least 2 mooring lines did not have rat guards.
Recommendation: Protect entry points where pests may enter the food areas. Ensure rat guards are made of a durable and non-chewable material. Use single-line, multiple-line, or conical shape rat guards according to the manufacturer's specifications. Ensure rat guards are on all lines that go ashore upon arrival and until at least one hour before the ship leaves port. Ensure each line has at least one rat guard placed either as far as practicable from the pier or as far as practicable from the ship while being able to stuff any openings with non-chewable material. Ensure rat guards are not staggered on adjacent lines and a group of lines do not merge onto one rat guard.
Item No.: 40
Site: Integrated Pest Management-Active Inspections
Violation: The records documenting the weekly active inspections indicated that all the active inspections all took place between 10 PM and 11:30 PM.
Recommendation: Ensure the IPM Plan sets a schedule for periodic active monitoring inspections, including some at night or during periods of no or minimal activity.
*Inspections scores of 85 or lower are NOT satisfactory