Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seadream II Cruise Line: Sea Dream Yacht Club Inspection Date: 12/27/2018 Inspection Score: 90
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 30
Site: Pantry-Deck 5
Violation: The handwashing station had no waste receptacle inside the pantry. The user had to get out of the door to the outer deck to dispose of the paper towel and come back to the pantry through the door. Corrections started immediately.
Recommendation: Ensure a handwashing facility includes a sink, soap dispenser, single-use towels dispenser, and waste receptacle.
Item No.: 35
Site: Pantry-Deck 5
Violation: Used water was splashing on the deck while the hood-type warewashing machine drained after wash cycles.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 39
Site: Pantry-Deck 5
Violation: After breakfast service, a fly was inside the pantry. The fly was on a previously cleaned plate when noticed by the inspection team.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 28
Site: Pantry-Deck 5
Violation: A fly was on a previously cleaned plate.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck unless in packages on pallets, skids, or racks, which may be 127 millimeters (5 inches).
Item No.: 40
Site: Pantry-Deck 5
Violation: The plastic curtains at the entrance door stuck to each other, creating gaps that were entryways for pests.
Recommendation: Ensure that the curtains cover all gaps that create entryways for pests.
Item No.: 33
Site: Pantry-Deck 5
Violation: The top of the bulkhead-mounted cleaning locker was heavily soiled. Cleaning started immediately.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Pantry-Deck 3
Violation: The technical space of the ice machine was soiled with dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 08
Site: Pantry-Deck 3
Violation: The backflow prevention device for the ice machine had the intermediate vents blocked by paint. This was also written on the inspection report of February 2018. The backflow prevention device was changed during the current inspection.
Recommendation: Maintain backflow prevention devices in good repair. Do not paint backflow prevention devices to avoid blocking intermediate vents with paint.
Item No.: 27
Site: Bar-Pool Bar
Violation: The upright refrigerator technical space was soiled with dust and a dead fly.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 40
Site: Bar-Pool Bar
Violation: A dead fly was in the upright refrigerator technical space.
Recommendation: Remove dead or trapped insects, rodents, and other pests from control devices and the vessel at a frequency that prevents their accumulation or decomposition or the attraction of other pests.
Item No.: 33
Site: Dining Room-The Dining Salon
Violation: The waiter stations had soft sealant as coving. The soft sealant was not hard, durable, easily cleanable, and of sufficient thickness to withstand normal wear.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Provide coving that is hard, durable, easily cleanable, and of sufficient thickness to withstand normal wear.
Item No.: 33
Site: Galley-Entrance
Violation: The top of the cleaning locker was soiled with dust.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 38
Site: Galley-Entrance
Violation: The wet mop in the cleaning locker was not stored in a position that allowed it to air dry.
Recommendation: After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
Item No.: 27
Site: Galley-Coffee Station
Violation: The top of the water dispenser was soiled with dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Coffee Station
Violation: The upright refrigerator technical space was soiled with dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Ice Machine
Violation: The space between the ice machine and the upright refrigerator was about 3 inches wide. This spacing between equipment made this area difficult to clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Provide sufficient, unobstructed space for cleaning around, behind, and between fixed equipment. The space provided is dependent on the distance either from a position directly in front or from either side of the equipment to the farthest point requiring cleaning. Please find additional guidance in sections 8.1.1 through 8.1.4 of the 2018 VSP Construction Guidelines.
Item No.: 27
Site: Galley-Ice Machine
Violation: The space between the ice machine and the upright refrigerator was soiled.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Ice Machine
Violation: A rough material was on the deck below and behind the ice machine. Staff stated that it seemed like dried paint.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Galley-Cold Section
Violation: The upright refrigerator technical space was soiled with dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Galley-Dishwash
Violation: The in-use rack-type warewasher had one upper spray arm nozzle blocked and not spraying. Staff replaced the nozzle after the finding.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 33
Site: Galley-Hot Section
Violation: The top of the bulkhead-mounted fire suppression system box was soiled with grease and debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Galley-Hot Section
Violation: The upright refrigerator technical space was soiled with dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Hot Section
Violation: The underside areas of both combination ovens were heavily soiled with grease. Cleaning started immediately.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Hot Section
Violation: The bulkhead under and behind undercounter refrigerator #22 was either soiled or had an encrusted dark material that was not easily cleanable.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 21
Site: Galley-Fish Refrigerator
Violation: The technical space of the upright fish refrigerator had holes and openings to difficult to reach areas, making this space difficult to clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Galley-Bakery/Pastry
Violation: The deckhead-mounted sprinkler in front of the deck oven was heavily soiled with dust.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Galley-Bakery/Pastry
Violation: The top of the microwave oven was soiled with dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 20
Site: Provisions-Deck 1 Holding/Thawing Room
Violation: The ambient temperature was around 57°F at the time of the inspection. Eggs and salmon were stored inside. About 1 hour later, the ambient temperature measured 54°F after technical staff adjusted the refrigeration system.
Recommendation: Ensure equipment for cooling and heating food, and holding cold and hot food, is sufficient in number and capacity to maintain potentially hazardous food temperatures.
Item No.: 16
Site: Provisions-Deck 1 Holding/Thawing Room
Violation: The internal temperature of six salmon fillets was 53°F. Staff took the salmon to a blast chiller. In addition, the inspection team tested a representative sample of eggs selected from 9 cases/360 eggs each, and the internal temperature of the eggs was 51-57°F. Staff stated that provisioning was about 7 days ago. Staff discarded these eggs after the finding and ordered new eggs, expecting them to arrive before departure time.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 02
Site: Medical-AGE 72-hour Questionnaire
Violation: The AGE 72-hour Questionnaire did not comply with the 2018 VSP Operations Manual. There was no designation if the case was a passenger or a crew member.
Recommendation: Distribute questionnaires detailing activities and meal locations for the 72 hours before illness onset to all passengers and crew members who are AGE CASES. Ensure that the self-administered questionnaires contain all of the data elements that appear in the questionnaire found in Annex 13.2.2. Ensure that completed questionnaires are maintained with the AGE surveillance log.
Item No.: 07
Site: Potable Water-Skin Tank Variance
Violation: The salinity meter for tank #4 was not working since 10 December. Staff conducted manual tests and recorded them as requested by the variance documents. Staff presented a purchase order for the prompt correction of this issue.
Recommendation: Ensure potable water tanks do not share a common wall with the hull of the vessel or with tanks or piping containing nonpotable water or other liquids. Repair the electronic salinity meter.
Item No.: 19
Site: Ventilation-Deck 2
Violation: Six large bottles of water were stored on the deck of this room next to AC unit #2. The water was in the middle of numerous mechanical parts, such as pumps, buckets, spare parts, and hoses.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; and (6) At least 150 millimeters (6 inches) above the deck on shelving racks. Do not store foods: (1) In locker rooms; (2) In toilet rooms; (3) In dressing rooms; (4) In garbage rooms; (5) In mechanical rooms; (6) Under sewer lines that are not continuously sleeve welded; (7) Under leaking water lines, including leaking automatic fire sprinkler heads, or under lines on which water has condensed; (8) Under open stairwells; (9) Under other sources of contamination from nonfood items such as ice blocks, ice carvings and flowers; or (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The plan dated January 2017 described the use of the disinfectant Accel TB, which was not onboard. Staff stated that this disinfectant was replaced by Oxivir TB and this was the chemical onboard along with Virox. Oxivir TB was not listed on the OPRP.
Recommendation: Update the OPRP.
Item No.: 44
Site: Potable Water-Disinfection Procedures
Violation: The team responsible for potable water was not aware that jobs that could potentially contaminate the potable water system, such as pipe replacements and backflow prevention device installations, needed disinfection procedures per section 5.3.4.1.4 and annex 13.6. The inspector advised the team and gave examples.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2018 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2018 Operations Manual as it relates to their assigned duties.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program