Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Costa Deliziosa Cruise Line: Costa Crociere S.P.A. Inspection Date: 12/19/2018 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 34
Site: Galley-Deck 1 Potwashing Area
Violation: At the entrance to the main galley, the portside toilet room was out-of-service due to plumbing related issue, while the starboard side toilet room had hair and dirty water on the wash counter surface next to the bowl. Remediation began immediately.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 34
Site: Galley-Deck 1 Pasta / Soup Kettle Area
Violation: In the technical space next to the soup kettles, water was dripping from the piping leading to the soup kettle-filling spout. This dripping water was pooling onto the deck. The area was not in use at the time of the inspection and had been previously cleaned. Remediation began immediately.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 28
Site: Galley-Deck 1 Garde Manger
Violation: The top edge of all four knife locker doors was soiled with dust. Additionally, the third door from the top would not close allowing the previously cleaned knives to remain unprotected. The knives in this locker were removed and recleaned.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck unless in packages on pallets, skids, or racks, which may be 127 millimeters (5 inches).
Item No.: 09
Site: Recreational Water Facilities-Analyzer-Chart Recorder Records - Center Whirlpool Spa Portside
Violation: Twelve separate instances, between 1 November 2018 and 18 November 2018, were observed on the analyzer-chart recorder records for the center whirlpool spa where the pH value during the manual test did not match the pH value recorded on the chart. Additionally, the pH values recorded on the analyzer-chart recorder records identified this recreational water facility operated outside of the acceptable pH range on many of these dates. On 1 November 2018, staff identified the manual test value for pH was 7.33, and the display value for pH was 7.48. The value on the analyzer-chart record was approximately 6.1. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 09:30. On 2 November 2018, staff identified the manual test value for pH was 7.49, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.25. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 10:30. On 3 November 2018, staff identified the manual test value for pH was 7.70, and the display value for pH was 7.79. The value on the analyzer-chart record was approximately 8.25. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached below 7.8 until 10:45. On 4 November 2018, staff identified the manual test value for pH was 7.42, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.5. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 11:00. On 6 November 2018, staff identified the manual test value for pH was 7.79, and the display value for pH was 8.01. The value on the analyzer-chart record was approximately 8.9. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached below 7.8 until 15:15. On 18 November 2018, staff identified the manual test value for pH was 7.48, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.00. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 15:30. Staff identified calibrations did not occur on any of these dates. Additional discrepancies between the analyzer-chart records and manual check values were observed on 5, 7, 8, 9, 10, 15, and 16 of November 2018. Staff stated a replacement staff member filled in during this time and left the position on 21 November 2018. Management did not provide any documentation to explain the difference between the analyzer-chart recorder records and the manual checks. Additionally, no information on corrective actions was provided.
Recommendation: Maintain the pH level in all RWFs between 7.0 and 7.8. Immediately close facilities if these halogen and pH ranges are not maintained.
Item No.: 28
Site: Pantry-Deck 2 Lobby
Violation: In the clean glass storage area, three previously cleaned glasses were stored inverted and wet. When the inspector turned the glasses over, the water inside began to drip from the glass. Remediation began immediately.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air-drying, and covered or inverted.
Item No.: 26
Site: Pantry-Deck 2
Violation: The ice machine's deflector panel had a 2-inch by 2-inch strip that had a sticky residue on the outside of the panel. This ice machine had a recirculating bath, so this side of the panel is considered a food-contact area. This sticky reside was slightly soiled with dust. Staff stated that there used to be a sticker on this panel and the glue was due to the removal of this sticker. Remediation began immediately.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 20
Site: Pantry-Deck 2
Violation: The ice machine's deflector panel had a 2-inch by 2-inch strip that had a sticky residue on the outside of the panel. This ice machine had a recirculating bath, so this side of the panel is considered a food-contact area. This sticky reside was slightly soiled with dust. Staff stated that there used to be a sticker on this panel and the glue was due to the removal of this sticker. This glue residue made the surface difficult to keep clean. Remediation began immediately.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
Item No.: 33
Site: Bar-Deck 2
Violation: The deckhead above the back bar liquor storage area had a 1-foot by 6-inch hole at the deckhead to bulkhead juncture. This hole allowed the plenum to be exposed and an excessive amount of dust to accumulate on the deckhead above this storage area. No food or previously cleaned utensil stored in this area was impacted. Remediation began immediately.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 22
Site: Galley-Deck 1 Potwashing Area
Violation: The external thermometer display gauge for the portside pot washing machine read a maximum temperature of 153°F during the wash cycle. The thermocouple device used by the inspector measured the maximum plate surface temperature at 159.6°F leaving a temperature differential of 6.6°F. The inspector's thermocouple device has an accuracy of +/- one (1) degree. It was determined that the pot washing machine was out-of-calibration. Remediation began immediately.
Recommendation: Ensure water temperature-measuring devices are scaled: (1) in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to within 1.5°C (within 3°F) in the intended range of use; (2) only in Fahrenheit are designed to be accurate to within 3°F in the intended range of use.
Item No.: 30
Site: Galley-Deck 1 Potwashing Area
Violation: At the entrance to the main galley, the portside toilet room was out-of-service due to plumbing related issue, while the starboard side toilet room had hair and dirty water on the wash counter surface next to the bowl. Remediation began immediately.
Recommendation: Keep handwashing facilities clean and in good repair.
Item No.: 33
Site: Galley-Deck 1 Pasta / Soup Kettle Area
Violation: In the technical space next to the soup kettles, water was dripping from the piping leading to the soup kettle-filling spout. This dripping water was pooling onto the deck. The area was not in use at the time of the inspection and had been previously cleaned. Remediation began immediately.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Galley-Deck 1 Garde Manger
Violation: The top edge of all four knife locker doors was soiled with dust. Additionally, the third door from the top would not close allowing the previously cleaned knives to remain unprotected. The knives in this locker were removed and recleaned.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Deck 1 Garde Manger
Violation: The third door from the top of the knife locker in this area would not close allowing the contents to remain unprotected once cleaned. The knives in this locker were removed and cleaned. Staff stated the door might be bent not allowing the hinge to operate properly. Remediation began immediately.
Recommendation: Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 33
Site: Galley-Deck 1 Portside Hot Line
Violation: Food debris was resting on the deck in front of the portside hot line area. The area was not-in-service at the time of the inspection and the area had been previously cleaned. Remediation began immediately.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Galley-Deck 1 Starboard Side Dishwashing Area
Violation: At the clean side of the flight-type dishwasher, a steady drip of water was coming from the deckhead, into the deckhead mounted light and onto the deck. The source of the water could not be identified. Remediation began immediately.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Galley-Deck 1 Toaster Area
Violation: The tops of two toaster ovens in this area were heavily soiled with dust. The area was previously cleaned and not in service at the time of the inspection. Remediation began immediately.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 37
Site: Preparation Room-Deck A Butcher Pot Washing Area
Violation: A heavy amount of condensation was coming from the pot washing machine's front hood-type door during normal operation. The condensation was forming on the deckhead outside of the ventilation hood area. No dripping was observed during the inspection and no previously cleaned utensils were impacted. Remediation began immediately.
Recommendation: Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 22
Site: Preparation Room-Deck A Butcher Pot Washing Area
Violation: A heavy amount of condensation was coming from the pot washing machine's front hood-type door during normal operation. The condensation was forming on the deckhead outside of the ventilation hood area. No dripping was observed during the inspection and no previously cleaned utensils were impacted. Remediation began immediately.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 38
Site: Preparation Room-Deck A Butcher Shop
Violation: In the butcher shop, an extra meat grinder that is not currently in use was soiled with rust inside the grinding chamber. Staff stated that this piece of equipment has not been used for an extended period and would be removed.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 33
Site: Provisions-Rooms B-13 and B-9
Violation: In both of these frozen storage rooms, a heavy amount of frozen condensation was on the deckhead and bulkheads. In these areas, the condensation covered approximately 80% of the deckhead. At least five boxes of frozen chicken had ice on the lids. All of the boxes of chicken were intact and the chicken was sealed in a plastic wrapper within the box. No food was impacted during the inspection. A provisioning plan to eliminate the condensation was discussed during the inspection.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 19
Site: Provisions-Rooms B-13 and B-9
Violation: In both of these frozen storage rooms, a heavy amount of frozen condensation was on the deckhead and bulkheads. In these areas, the condensation covered approximately 80% of the deckhead. At least five boxes of frozen chicken had ice on the box lids. All of the boxes of chicken were intact and the chicken was sealed in a plastic wrapper within the box. No food was impacted during the inspection. A provisioning plan to eliminate the condensation was discussed during the inspection.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
Item No.: 29
Site: Other-Garbage Room
Violation: The handwashing sink in the garbage room was blocked and heavily soiled with food debris. Remediation began immediately.
Recommendation: Ensure handwashing facilities are used for no other purpose and are accessible at all times.
Item No.: 30
Site: Other-Garbage Room
Violation: The handwashing sink in the garbage room was blocked and heavily soiled with food debris. Remediation began immediately.
Recommendation: Keep handwashing facilities clean and in good repair.
Item No.: 39
Site: Galley-Deck 9
Violation: Two houseflies were observed in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 38
Site: Galley-Deck 9
Violation: Two wet, soiled mops were stored resting on the deck and not in the cleaning locker. The area was not in use at the time of the inspection. Remediation began immediately.
Recommendation: After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies. Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles.
Item No.: 08
Site: Buffet-Deck 9 Portside - Forward Coffee Station
Violation: The undercounter backflow prevention device for the forward coffee maker was continuously dripping water. Remediation began immediately.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 39
Site: Buffet-Deck 9 Portside - Forward Coffee Station
Violation: In the technical space below the coffee station, seven fruit flies were observed in and around the scupper. The IPM manager was notified.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 27
Site: Buffet-Deck 9 Portside - Aft Coffee Station
Violation: The two backflow prevention devices for the coffee makers were heavily soiled and corroded. These devices were not dripping at the time of the inspection. Remediation began immediately.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 39
Site: Buffet-Deck 9 Portside - Aft Coffee Station
Violation: In the undercounter technical compartment below the coffee makers, four fruit flies were noticed. The IPM manager was notified.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Deck 9 Portside - Cold Galley
Violation: One housefly was observed. The IPM manager was notified.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 24
Site: Galley-Deck 10 Dishwashing Area
Violation: The three-compartment sink sanitizing tub measured a temperature of 151°F. No pots, dishes, or utensils were in the sink at the time of the inspection. Remediation began immediately.
Recommendation: In a manual operation, if immersion in hot water is used for sanitizing, ensure: (1) the temperature of the water is maintained at 77°C (171°F) or above and (2) the food-contact surface is immersed for at least 30 seconds.
Item No.: 20
Site: Galley-Deck 10 Pastry
Violation: Six undercounter refrigeration units were out-of-order at the time of the inspection. Work orders stated these units were out-of-order since 12 December 2018. The inspection took place on 19 December 2018.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
Item No.: 37
Site: Galley-Deck 10 Bain Marie Station
Violation: At the bain-marie station, condensation was observed collecting on the countertop and on the back bulkhead. No food was impacted at the time of the inspection.
Recommendation: Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 27
Site: Preparation Room-Deck A Butcher Shop
Violation: In the butcher shop, an extra meat grinder that is not currently in use was soiled with rust on the non-food contact surface of the grinding chamber. Staff stated that this piece of equipment has not been used for an extended period and would be removed.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 08
Site: Potable Water-Bunkering Records
Violation: The bunkering of potable on 30 November 2018 began at 08:30 and stopped at 12:00. A shore-side pretest was recorded on the bunkering analyzer chart record. When potable water bunkering resumed at 12:30, there was no shore-side pretest recorded on the analyzer chart record, or another document to establish the correct halogen dosage.
Recommendation: After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least hourly during the bunkering of potable water. After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least once every 4 hours during the production of potable water. Ensure a test kit is available for testing free halogen levels and pH. Ensure test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the potable water system. Ensure test kits for pH are accurate to within 0.2.
Item No.: 10
Site: Recreational Water Facilities-Analyzer Chart Records - Whirlpool Spa Aft Starboard
Violation: The analyzer-chart records for the whirlpool spa aft starboard, dated 19 November 2018 until 18 December 2018, were not initialed. There were no initials or signature present on any records for this recreational water facility during this period.
Recommendation: Initial, date, and change halogen analyzer-chart recorder charts daily. Initial and date strip recorder charts daily and indicate 24-hour increments. Ensure dual-scale halogen analyzer-chart recorder charts used in recreational water facilities are able to measure the full range of halogen/pH of the facility type for which the chart is installed.
Item No.: 10
Site: Recreational Water Facilities-Analyzer-Chart Records - Whirlpool Spa Aft Portside
Violation: The analyzer-chart records for the whirlpool spa aft portside, dated 19 November 2018 until 18 December 2018, were not initialed daily. There were no initials or signature present on any records for this recreational water facility during this period.
Recommendation: Initial, date, and change halogen analyzer-chart recorder charts daily. Initial and date strip recorder charts daily and indicate 24-hour increments. Ensure dual-scale halogen analyzer-chart recorder charts used in recreational water facilities are able to measure the full range of halogen/pH of the facility type for which the chart is installed.
Item No.: 41
Site: Other-Deck A Engine Handwashing Station
Violation: A sign stating 'wash hands often,' 'wash hands frequently,' or similar wording in a language that the food employees understand was not posted above the handwashing sink. Corrections started immediately.
Recommendation: Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log
Violation: The underlying illness column for a reportable case passenger, with illness onset on 8 December 2018 at 08:00, was completed as 'this form is filled in substitution.' Staff stated this reportable case did not have an underlying illness. The words 'none,' 'not applicable,' 'N/A,' or similar wording were not present on the AGE log, or in the electronic medical reporting software.
Recommendation: Ensure the AGE surveillance log includes a header containing the following information about the voyage: (1) Vessel name; (2) Voyage number; (3) Date from; (4) Date to; (5) Total number of passengers; (6) Reportable total number of passengers ill; (7) Total number of crew; (8) Reportable total number of crew ill. Total number of passengers and total number of crew must be the totals at the beginning of the voyage (i.e., totals on ?date from?). Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Patient ID; (2) Date of the first medical visit or report to staff of illness; (3) time of the first medical visit or report to staff of illness; (4) person's last name; (5) person's first name; (6) person's age; (7) person's sex; (8) designation as passenger or crew member; (9) cabin number; (10) crew member position or job on the vessel, if applicable; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24 hour period; (b) bloody stools (yes/no); (c) number of episodes of vomiting in a 24 hour period; (d) fever (yes/no); (e) abdominal cramps (yes/no); (f) headaches (yes/no); (g) myalgia (yes/no); (14) date of last symptom; (15) time of last symptom; (16) entry (yes/no) for whether a specimen was requested; (17) entry (yes/no) for whether a specimen was received; (18) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (19) entry (yes/no) for whether this was a reportable case; (20) presence of underlying medical conditions that may affect interpretation of AGE. If none, write ?none,? ?not applicable,? ?N/A,? r similar wording. Comments may also be added to the log in this column after the information about underlying illness. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
Item No.: 10
Site: Recreational Water Facilities-Analyzer-Chart Recorder Records - Center Whirlpool Spa Portside
Violation: Twelve separate instances, between 1 November 2018 and 18 November 2018, were observed on the analyzer-chart recorder records for the center whirlpool spa where the pH value during the manual test did not match the pH value recorded on the chart. Additionally, the pH values recorded on the analyzer-chart recorder records identified this recreational water facility operated outside of the acceptable pH range on many of these dates. On 1 November 2018, staff identified the manual test value for pH was 7.33, and the display value for pH was 7.48. The value on the analyzer-chart record was approximately 6.1. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 09:30. On 2 November 2018, staff identified the manual test value for pH was 7.49, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.25. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 10:30. On 3 November 2018, staff identified the manual test value for pH was 7.70, and the display value for pH was 7.79. The value on the analyzer-chart record was approximately 8.25. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached below 7.8 until 10:45. On 4 November 2018, staff identified the manual test value for pH was 7.42, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.5. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 11:00. On 6 November 2018, staff identified the manual test value for pH was 7.79, and the display value for pH was 8.01. The value on the analyzer-chart record was approximately 8.9. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached below 7.8 until 15:15. On 18 November 2018, staff identified the manual test value for pH was 7.48, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.00. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 15:30. Staff identified calibrations did not occur on any of these dates. Additional discrepancies between the analyzer-chart records and manual check values were observed on 5, 7, 8, 9, 10, 15, and 16 of November 2018. Staff stated a replacement staff member filled in during this time and left the position on 21 November 2018. Management did not provide any documentation to explain the difference between the analyzer-chart recorder records and the manual checks. Additionally, no information on corrective actions was provided.
Recommendation: Maintain and operate the halogen and pH analyzer-chart recorder in accordance with the manufacturer?s instructions. Conduct a manual comparison test before opening the RWF to verify calibration for free halogen residual and pH. Ensure the analyzer reading is within 0.2 ppm for free halogen and 0.2 for pH 7.0 to 7.8. For RWFs open longer than 24 hours, conduct a manual comparison test every 24 hours. Ensure logs and charts contain notations outlining actions taken when the free halogen residual or pH levels are outside of the acceptable ranges in this manual. Additionally, ensure the records include any major maintenance work on the filtration and halogenation systems and UV disinfection systems. Ensure a written or electronic log of RWF filter inspection results, granular filter sedimentation test results, backwashing frequency and length of backwashing, and date and time of water dumping is available for review during inspections. Ensure dual-scale halogen analyzer-chart recorder charts used in recreational water facilities are able to measure the full range of halogen/pH of the facility type for which the chart is installed.
Item No.: 44
Site: Recreational Water Facilities-Analyzer-Chart Recorder Records - Center Whirlpool Spa Portside
Violation: Twelve separate instances, between 1 November 2018 and 18 November 2018, were observed on the analyzer-chart recorder records for the center whirlpool spa where the pH value during the manual test did not match the pH value recorded on the chart. Additionally, the pH values recorded on the analyzer-chart recorder records identified this recreational water facility operated outside of the acceptable pH range on many of these dates. On 1 November 2018, staff identified the manual test value for pH was 7.33, and the display value for pH was 7.48. The value on the analyzer-chart record was approximately 6.1. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 09:30. On 2 November 2018, staff identified the manual test value for pH was 7.49, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.25. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 10:30. On 3 November 2018, staff identified the manual test value for pH was 7.70, and the display value for pH was 7.79. The value on the analyzer-chart record was approximately 8.25. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached below 7.8 until 10:45. On 4 November 2018, staff identified the manual test value for pH was 7.42, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.5. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 11:00. On 6 November 2018, staff identified the manual test value for pH was 7.79, and the display value for pH was 8.01. The value on the analyzer-chart record was approximately 8.9. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached below 7.8 until 15:15. On 18 November 2018, staff identified the manual test value for pH was 7.48, and the display value for pH was 7.51. The value on the analyzer-chart record was approximately 6.00. Additionally, this facility was opened at 08:00; however, the analyzer-chart record did not identify the pH reached 7.0 until 15:30. Staff identified calibrations did not occur on any of these dates. Additional discrepancies between the analyzer-chart records and manual check values were observed on 5, 7, 8, 9, 10, 15, and 16 of November 2018. Staff stated a replacement staff member filled in during this time and left the position on 21 November 2018. Management did not provide any documentation to explain the difference between the analyzer-chart recorder records and the manual checks. Additionally, no information on corrective actions was provided.
Recommendation: Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP?during inspections and on request ? knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2018 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2018 Operations Manual as it relates to their assigned duties.
Item No.: 10
Site: Recreational Water Facilities-Analyzer-Chart Records - Center Whirlpool Spa Portside
Violation: The analyzer-chart recorder record, dated 20 November 2018 for the center whirlpool spa portside, did not identify the time the manual check occurred. The additional record provided identified a manual comparison occurred; however, there was no documentation to identify this manual comparison occurred prior to opening the facility.
Recommendation: Maintain and operate the halogen and pH analyzer-chart recorder in accordance with the manufacturer?s instructions. Conduct a manual comparison test before opening the RWF to verify calibration for free halogen residual and pH. Ensure the analyzer reading is within 0.2 ppm for free halogen and 0.2 for pH 7.0 to 7.8. For RWFs open longer than 24-hours, conduct a manual comparison test every 24-hours. Initial, date, and change halogen analyzer-chart recorder charts daily. Initial and date strip recorder charts daily and indicate 24-hour increments. Ensure dual-scale halogen analyzer-chart recorder charts used in recreational water facilities are able to measure the full range of halogen/pH of the facility type for which the chart is installed.
Item No.: 10
Site: Recreational Water Facilities-Analyzer-Chart Records - Whirlpool Spa Center Portside
Violation: The analyzer-chart recorder charts for the whirlpool spa center portside, dated 19 November 2018 until 25 November 2018, and were not initialed daily. There were no initials or signature present on any records for this recreational water facility during this period.
Recommendation: Initial, date, and change halogen analyzer-chart recorder charts daily. Initial and date strip recorder charts daily and indicate 24-hour increments. Ensure dual-scale halogen analyzer-chart recorder charts used in recreational water facilities are able to measure the full range of halogen/pH of the facility type for which the chart is installed.
Item No.: 10
Site: Recreational Water Facilities-Super halogenation Log - Center Whirlpool Spa Portside
Violation: The recreational water facility super halogenation log, dated 18 November, identified the center whirlpool spa portside was filled on 24 November 2018 at 03:30; however was not drained until 27 November 2018 at 21:45. This period was longer than 72 hours. Additionally, review of the analyzer-chart records identified this facility operated below the required halogen residual once it was closed at 20:00.
Recommendation: Change the whirlpool spa water, including compensation tank, filter housing, and associated piping, every 72 hours, provided that the system is operated continuously and that the correct water chemistry levels are maintained during that period, including daily shock halogenation. Change spa pool water as often as necessary to maintain proper water chemistry. Change the water at least every 30 days. Record the date and time of whirlpool spa and spa pool water changes in the log.
Item No.: 10
Site: Recreational Water Facilities-Super halogenation Log - Center Whirlpool Spa Starboard
Violation: The recreational water facility super halogenation log, dated 18 November, identified the center whirlpool spa starboard was drained on 23 November 2018 at 21:45. The analyzer-chart recorder records for this facility identified it was opened on 24 November 2018 at 08:00. The super halogenation log, dated nov-18, identified this recreational water facility was not drained until 27 November 2018 at 21:45. This period was longer than 72 hours.
Recommendation: Change the whirlpool spa water, including compensation tank, filter housing, and associated piping, every 72 hours, provided that the system is operated continuously and that the correct water chemistry levels are maintained during that period, including daily shock halogenation. Change spa pool water as often as necessary to maintain proper water chemistry. Change the water at least every 30 days. Record the date and time of whirlpool spa and spa pool water changes in the log.
Item No.: 10
Site: Recreational Water Facilities-Fecal/Vomit Accident Plan
Violation: The ship's fecal/vomit accident plan did not stipulate maintaining a temperature at 77°F or higher during super chlorination. This is a new requirement for the 2018 VSP Operations Manual.
Recommendation: Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Super halogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing. Ensure heated activity pools, including interactive RWFs, that have features that break the water surface of the RWF or create a mist are shock halogenated as described. This includes activity pools and interactive RWFs that can be heated by the sun and/or exterior temperature. Maintain a temperature of 77°F during this operation.
Item No.: 43
Site: Recreational Water Facilities-Deck 7 A.C. Station 4.5
Violation: The droplet eliminator tray for the air-handling unit was soiled with a light brown residue. When the inspector wiped over this surface, a black and brown film was observed. Staff stated this eliminator tray was last cleaned in October 2018.
Recommendation: Keep air handling units clean.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program