Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Kydon Cruise Line: Ferries Del Caribe Inspection Date: 01/21/2019 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 16
Site: Other-Bridge
Violation: A tray of cut fruit, including water melon and cantaloupe, was stored in a small refrigerator. The temperature of the fruit was measured between 46 and 48°F. The fruit did not have a 7-day discard label. Staff stated the fruit was brought up to the bridge in the evening and discarded in the morning. The inspection team was in the area at approximately 10:15 am. The fruit was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less. Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
Item No.: 20
Site: Other-Bridge
Violation: The ambient temperature of the small refrigerator was measured by the inspector at 48°F. A small tray of cut fruit, including watermelon and cantaloupe was stored in the refrigerator. The tray was removed and a sign was posted on the door indicating only water should be stored inside.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 26
Site: Other-Bridge
Violation: A small espresso machine on the counter next to the small refrigerator was soiled with coffee residue in the food-splash area. Staff stated the machine had not been used for almost two years because the espresso pods could no longer be purchased.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 38
Site: Other-Bridge
Violation: A small espresso machine on the counter next to the small refrigerator was soiled with coffee residue in the food-splash area. Staff stated the machine had not been used for almost two years because the espresso pods could no longer be purchased.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 19
Site: Other-Bridge
Violation: Five used cups and coffee mugs were stored on the counter adjacent to a container of individually packaged sweeteners.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; and (6) At least 150 millimeters (6 inches) above the deck on shelving racks.
Item No.: 22
Site: Other-Bridge
Violation: Five used cups and coffee mugs were stored on the counter adjacent to a container of individually packaged sweeteners.
Recommendation: Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
Item No.: 30
Site: Galley-
Violation: There was no water at the handwash station next to the walk-in refrigerator. There was an operational handwash station within 8 meters.
Recommendation: Keep handwashing facilities clean and in good repair.
Item No.: 34
Site: Galley-
Violation: The prerinse hose at the long utility sink adjacent to the walk-in refrigerator was leaking excessively.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 21
Site: Galley-Dishwash/Potwash Area
Violation: The handle on the cleaning locker door had broken off, exposing a gap and difficult to clean features.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 38
Site: Galley-Dishwash/Potwash Area
Violation: In the corridor directly outside the dishwash area, two mops were stored in buckets. The storage of the mops did not allow them to drain and dry.
Recommendation: After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
Item No.: 22
Site: Galley-Dishwash/Potwash Area
Violation: The upper final rinse spray nozzles on the rack-type conveyor warewash machine did not form an effective spray pattern. In addition, a stream of water was leaking from the top, left side of the spray arm. The machine was making a very loud noise, and staff stated the vibration from the problem with the machine had dislocated a clip for the final rinse manifold.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: *
Site: Galley-Dishwash/Potwash Area
Violation: The rack-type conveyor warewash machine was making a very loud noise during operation. Staff stated a technician from the manufacturer had been contacted to repair the machine. The machine was still operational and able to meet the requirement temperatures, but the vibration was causing the final rinse manifold to dislocate.
Recommendation: Repair the machine.
Item No.: 21
Site: Dining Room-POS Counter
Violation: There was a gap where the countertop met the bulkhead. There was a also a gap where the long cabinet met the short cabinet. Items such as table linens, clean glasses, and bottled wine were stored in the long cabinet.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Dining Room-POS Counter
Violation: The deck between the long and short cabinets was soiled.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Buffet-
Violation: On the worker's side of the buffet, the tops of the cove tiles where they met the bulkhead were rough and difficult to clean. They were also dusty.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 39
Site: Buffet-
Violation: A small fly was at the end of the service line near the galley entrance doors. Staff had plans to install a fly trap in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Bakery
Violation: One large fly was in the area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 14
Site: Galley-Hot Galley
Violation: The chef actively cooking fish had a prominent mustache but was not wearing a protective covering. It was discussed he could wear a beard net or trim his mustache.
Recommendation: Ensure food employees wear hair restraints and clothing that covers body hair. Ensure these items are designed and worn effectively to prevent hair from contacting exposed food; clean equipment, utensils, and linens; and unwrapped single-service and single-use articles. This also applies to partial beards (such as goatees) and to heavy, pronounced mustaches.
Item No.: 21
Site: Provisions-Dry Store
Violation: The portable pressed-wood style cabinet stored near the entrance to the room had difficult to clean features such as a chipped bottom, a hole in the top, and a rough surface where the top counter met the back. Staff stated the cabinet could be removed.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Provisions-Dry Store
Violation: Two new air ducts had been installed in the room but the covers were not yet in place. Staff stated the covers were on the ship and would be installed.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 33
Site: Provisions-Frozen Vegetable Freezer
Violation: Ice was accumulated on the deck below the condenser unit.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 21
Site: Provisions-Frozen Vegetable Freezer
Violation: The condenser unit was covered in frost and ice.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 02
Site: Medical-Bacterial Specimen Collection Containers
Violation: The bacterial specimen collection containers had expired in April 2018.
Recommendation: Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each).
Item No.: 08
Site: Potable Water-
Violation: No backflow prevention devices were installed on the international shore connections. This was written on the December 2017, March 2018, and May 2018 inspections. In addition, approximately 25 of the toilets only had dual check valves with no intermediate atmospheric vent and all of the cabin shower hoses only had dual check valves with no intermediate atmospheric vent on the hot and cold water supply lines. These were written on the July 2017, December 2017, March 2018, and May 2018 inspections. Staff provided documentation that the devices had been ordered and would be installed when received.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (1) RWFs; (2) decorative water features/fountains; (3) cabin shower hoses, toilets, whirlpool tubs, and similar facilities; (4) photographic laboratory developing machines and utility sinks; (5) beauty and barber shop spray-rinse hoses; (6) spa steam generators where essential oils can be added; (7) hose-bib connections; (8) garbage grinders and food waste systems; (9) automatic galley hood washing systems; (10) food service equipment; (11) mechanical warewashing machines; (12) detergent dispensers; (13) hospital and laundry equipment; (14) air conditioning expansion tanks; (15) boiler feed water tanks; (16) fire system; (17) public toilets, urinals, and shower hoses; (18) potable water, bilge, and pumps that require priming; (19) freshwater or saltwater ballast systems; (20) international fire and fire sprinkler water connections (install a reduced pressure assembly); (21) the potable water supply to automatic window washing systems that can be used with chemicals or chemical mix tanks; (22) water softeners for nonpotable fresh water; (23) water softener and mineralizer drain lines, including backwash drain lines (install an air gap or a reduced pressure assembly); (24) high saline discharge line from evaporators (install an air gap or a reduced pressure assembly); (25) chemical tanks; (26) other connections between the potable water system and a nonpotable water system, such as the gray water system, laundry system, or technical water system (install an air gap or a reduced pressure assembly); (27) black water or combined gray water/black water systems (install an air gap); (28) Hi-Fog or similar suppression systems which are connected to potable water tanks; (29) any other connection to the potable water system where contamination or backflow can occur.
Item No.: 07
Site: Potable Water-
Violation: No reduced pressure zone assembly backflow prevention device (RP) or air gap was installed on the connection between potable and technical water. This was written on the December 2017, March 2018, and May 2018 inspections. The device was on the vessel, but staff were waiting for the vendor to install the device.
Recommendation: Protect the potable water system against backflow or other contamination by backflow prevention devices or air gaps. Ensure the permeate lines and distillate lines directed toward the potable water system are also protected.
Item No.: 08
Site: Potable Water-
Violation: The list of backflow prevention devices did not include the type of device or the type of connection. This was written on the December 2017, March 2018, and May 2018 inspections. Staff stated they would update the list when the new devices were received and installed.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 33
Site: Provisions-Dry Store
Violation: The deck was made of a vinyl material, which was not considerable durable. In addition, it had many bumps, seams, ridges, and scratches. It was discussed that a painted steel deck would be acceptable and the vessel was planning to replace the deck during the February 2019 dry dock. It was also discussed that if the deck below the vinyl material was steel, it could be painted and would be acceptable as long as it was smooth and easily cleanable.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program