|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Log
|
|
Violation:
The current version of the AGE log did not list the date and time of the case last symptoms per section 4.1.2.1.3. Additionally, this log was not in the same format as required by annex 13.2.2 of the 2018 VSP Operations Manual. This is a new requirement of the June 2018 VSP Operations Manual.
|
|
Recommendation:
Ensure the AGE surveillance log includes a header containing the following information about the voyage: (1) Vessel name; (2) Voyage number; (3) Date from; (4) Date to; (5) Total number of passengers; (6) Reportable total number of passengers ill; (7) Total number of crew; (8) Reportable total number of crew ill. Total number of passengers and total number of crew must be the totals at the beginning of the voyage (i.e., totals on ?date from?). Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Patient ID; (2) Date of the first medical visit or report to staff of illness; (3) time of the first medical visit or report to staff of illness; (4) person's last name; (5) person's first name; (6) person's age; (7) person's sex; (8) designation as passenger or crew member; (9) cabin number; (10) crew member position or job on the vessel, if applicable; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24 hour period; (b) bloody stools (yes/no); (c) number of episodes of vomiting in a 24 hour period; (d) fever (yes/no); (e) abdominal cramps (yes/no); (f) headaches (yes/no); (g) myalgia (yes/no); (14) date of last symptom; (15) time of last symptom; (16) entry (yes/no) for whether a specimen was requested; (17) entry (yes/no) for whether a specimen was received; (18) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (19) entry (yes/no) for whether this was a reportable case; (20) presence of underlying medical conditions that may affect interpretation of AGE. If none, write ?none,? ?not applicable,? ?N/A,? for similar wording. Comments may also be added to the log in this column after the information about underlying illness. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Testable Backflow Prevention Device Log
|
|
Violation:
The testable backflow prevention device log stated three devices were tested on 2 February 2018, 4 February 2018, and 8 February 2018; however, in a separate document the annual test conducted in 2019 for these three devices was listed on 4 February, 7 February, and 8 February respectively. Staff was confused because two separate spreadsheets stated different annual testing times for 2018 and 2019. Staff stated the ship would update the master spreadsheet to reflect the current testing schedule.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing (e.g., reduced pressure backflow prevention devices and pressure vacuum breakers) with a test kit after installation and at least annually. Maintain test results showing the pressure differences on both sides of the valves. Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water Bunkering Line
|
|
Violation:
The distance between the halogen injection point and the analyzer probe (sample point) on the bunker line was measured by the inspector and staff at 8-feet 3-inches. The bunker line did not have a static mixer installed between the two injection and sample sites.
|
|
Recommendation:
Obtain water samples for halogen and pH testing from a sample cock and/or a halogen analyzer probe located on the bunker or production water line at least 3 meters (10 feet) after the halogen injection point and before the storage tank.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Terrace Pool
|
|
Violation:
While the pool was open for passengers, the water level was below the skim gutter level. Staff closed the pool during the inspection while the water level was raised.
|
|
Recommendation:
For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters.
|
|
|
Item No.:
18
|
|
Site:
Galley-Cold Larder
|
|
Violation:
In undercounter refrigerator #10, pans of cold smoked salmon and cold smoked trout were stored above a ready-to-eat seafood salad. This was corrected.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Leading Hands Mess
|
|
Violation:
The hand-contact portion of a pair of tongs was resting in a container of biscuits. This was corrected.
|
|
Recommendation:
During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container; (2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon; (3) On a clean portion of the food preparation table or cooking equipment only if the in-use utensil and the food-contact surface of the food preparation table or cooking equipment are cleaned and sanitized at least every 4 hours; (4) In running water of sufficient velocity to flush particulates to the drain (if used with moist food such as ice cream or mashed potatoes); (5) In a clean, protected location (if the utensils, such as ice scoops, are used only with a food that is not potentially hazardous); or (6)In a container of water (if the water is maintained at a temperature of at least 57°C [135°F] and the container is frequently cleaned and sanitized).
|
|
|
Item No.:
19
|
|
Site:
Provisions-Forward Loading Area
|
|
Violation:
Four cases of bottled water were being stored on the deck in this area. Remediation began immediately.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; and (6) At least 150 millimeters (6 inches) above the deck on shelving racks.
|
|
|
Item No.:
19
|
|
Site:
Other-Engine Control Room Office Area
|
|
Violation:
Multiple water bottles were stored on the deck throughout the office area. Remediation began immediately.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; and (6) At least 150 millimeters (6 inches) above the deck on shelving racks.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-Butcher
|
|
Violation:
Two cutting boards were fuzzy and scored, making them difficult to clean. They were discarded. The area was open for service during the inspection; however, no food was impacted.
|
|
Recommendation:
Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 5 Pastry
|
|
Violation:
The dough sheeter was out-of-order since 7 February 2019.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 5 Pastry
|
|
Violation:
The steam kettle had been out-of-order since 15 January 2019. Staff stated they used an alternate steam kettle located in another area of the galley.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 5 Pastry
|
|
Violation:
Two slotted fasteners were located in the food splash zone of the rotating arm on the counter-mounted mixer.
|
|
Recommendation:
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 5 Ambient Bread Locker
|
|
Violation:
There was a large crack on the side of one plastic bread container. This container was discarded.
|
|
Recommendation:
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
20
|
|
Site:
Pantry-Frankie's Bar Pantry
|
|
Violation:
Two cutting boards were found fuzzy and scored. They were sent be staff to be resurfaced. The area was open during the inspection; however, no food was impacted.
|
|
Recommendation:
Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
21
|
|
Site:
Galley-Bar Pantry
|
|
Violation:
Cords from the espresso machine were draped across the counter top making this area difficult to clean. This was corrected.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Saffron Beverage Station
|
|
Violation:
Cords were draped across the counter top underneath both coffee machines making the area difficult to clean. This was corrected.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Galley-Saffron Portside Forward Dishwash
|
|
Violation:
The previously-cleaned flight-type dishwash was not in service during the inspection; however, one prong of the roller was soiled with what appeared to be a type of lubricant used in the machine. The machine was cleaned.
|
|
Recommendation:
Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination and accumulation of excessive debris, and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
|
|
|
Item No.:
22
|
|
Site:
Pantry-Medical
|
|
Violation:
A heavy amount of steam was escaping from the front door area of the undercounter dishwash machine during general operation. A wash tank temperature of 172°F was measured with a tip-sensitive measuring device during the inspection which contributed to the excess amount of steam. The dishwashing machine's internal thermometer was consistent with the wash tank temperature measured by the inspector and staff. No condensation was formed on the deckhead during the inspection. Remediation began immediately.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
26
|
|
Site:
Galley-Dishwashing Area
|
|
Violation:
Four previously cleaned utensils were found with food debris on the food-contact surface. They were sent to be rewashed.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Pantry-House Keeping
|
|
Violation:
The house keeping pantry ice machines on decks 11, 12, and 14 were soiled with brown debris on many areas of the plastic housing surrounding the evaporator unit. Additionally, black debris was found on the water arm. The inspector used an alcohol pad to remove the debris during the inspection. All three of the ice machines were closed for cleaning during the inspection.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Pantry-Medical
|
|
Violation:
The inside food-splash area of the microwave oven was soiled with food debris. The inspector used an alcohol pad to remove the debris. Cleaning began immediately.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Hot Galley Line
|
|
Violation:
One previously cleaned plate cover had what appeared to be a sticker on the inside food splash surface. This was sent to be rewashed.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
26
|
|
Site:
Preparation Room-Vegetable Prep
|
|
Violation:
Seventeen large plastic, blue, previously cleaned bins were stored wet nested. The bottom of one of the stacked bins was soiled with food debris as it rested inside another container. The bins were rewashed and allowed to air-dry.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
26
|
|
Site:
Galley-Sindhu
|
|
Violation:
One previously cleaned dish located in the ambient storage locker was found soiled. This was sent to be rewashed.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
27
|
|
Site:
Pantry-Engine Control Room
|
|
Violation:
The countertop surface under the coffee maker was soiled with dust and liquid food debris. Additionally, the top of the coffee maker was soiled with accumulated dust. An alcohol pad was used to remove the debris from both surfaces. Cleaning began immediately.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Preparation Room-Vegetable Preparation
|
|
Violation:
Seventeen large plastic, blue, previously cleaned bins were stored wet nested. The bottom of one of the stacked bins was soiled with food debris. The bins were rewashed and allowed to air dry.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
29
|
|
Site:
Galley-Deck 5 Starboard
|
|
Violation:
The right-most handwash station located across from the ice machines reached a maximum temperature of 84°F. This area of the galley was not in use during the inspection. The hot water to the sink had been shut off. This was corrected.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|
|
Item No.:
30
|
|
Site:
Galley-
|
|
Violation:
The handwash sink located near the fishpond was out-of-order since 19 February. Staff stated the water supply pipe had a leak.
|
|
Recommendation:
Keep handwashing facilities clean and in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Cold Room 15711
|
|
Violation:
Water was dripping consistently from the hatch in the deckhead outside cold room 15711. The source of the drip could not be determined.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 5 Starboard
|
|
Violation:
At the time of the inspection, water was pooled on the deck in front of three handwash sinks located across from the ice machines. When the deck tiles were stepped on, water bubbled up from beneath the tiles. The source of the water could not be identified. Remediation began immediately.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-Vegetable Holding Walk-in Unit #4719
|
|
Violation:
Water was dripping from a seam in the middle of the deckhead. This was reported on 18 February. The dripping affected no food.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
34
|
|
Site:
Galley-Deck 5 Potwash
|
|
Violation:
The bucket-filling spout under the handwash sink was steadily leaking. This was reported by staff on the morning of the inspection.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
34
|
|
Site:
Galley-Deck 5 Starboard
|
|
Violation:
The hot water supply to the right-most handwash sink located across from the ice machines was turned off. This was corrected.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
34
|
|
Site:
Galley-Beach House Pantry
|
|
Violation:
The faucet of the utility sink was dripping continuously. The drip had been previously reported on 8 February.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
34
|
|
Site:
Galley-Beach House
|
|
Violation:
Water was pooling on the deck at the entrance to the beach house galley. A nearby drain was blocked causing the water to pool on the deck.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Engine Control Room
|
|
Violation:
The light intensity above the pantry countertop was insufficient. The light intensity of 220 lux was not met. Remediation began immediately.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
38
|
|
Site:
Galley-Deck 5 Pastry
|
|
Violation:
The steam kettle had been out-of-order since 15 January 2019. Staff stated they used an alternate steam kettle located in another area of the galley.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
39
|
|
Site:
Bar-Aguana
|
|
Violation:
One large flying insect was observed in this area.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|