Item No.:
08
|
|
Site:
Potable Water-Engine Room
|
|
Violation:
The potable water line traveling to the grease trap was not striped blue or blue/green/blue every 5 meters (15 feet). Also, in the forward engine room on the port side, the potable water line above the fuel separator was striped blue/brown/blue. The water pipe after the reduced pressure assembly suppling the laundry room was striped blue indicating potable water.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Patio
|
|
Violation:
The posted consumer advisory for the hamburgers at The Patio, did not include the statement; cooked-to order. This was corrected during the inspection.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
18
|
|
Site:
Galley-Port Cold Galley
|
|
Violation:
A plate of cold smoked salmon was stored on the top shelf above ready-to-eat artichokes in the right compartment of undercounter refrigerator 040202.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
18
|
|
Site:
Galley-Port Walk-in Refrigerator
|
|
Violation:
A tray of cold smoked salmon was stored on the top shelf of a movable trolley above other ready-to-eat foods such as cooked shrimp and deli meats.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Officer's Mess
|
|
Violation:
The sneeze shield in place for the self-service ice cream well did not provide adequate protection for the ice cream scoop well.
|
|
Recommendation:
During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
|
|
|
Item No.:
20
|
|
Site:
Galley-Port Blast Chiller
|
|
Violation:
The blast chiller had been out-of-order since 20 March. Staff provided documentation that showed the spare parts needed to repair the blast chiller were due to arrive the day of the inspection.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
|
|
|
Item No.:
20
|
|
Site:
Buffet-TK Grill
|
|
Violation:
The eight large wooden bowls used for salads were not made of a hard, durable, and easily cleanable material. The bottom inside area of multiple bowls were worn with small chips and scratches.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
|
|
|
Item No.:
20
|
|
Site:
Food Service General-Dehydration Units
|
|
Violation:
The three new dehydration units, which were in the port and starboard cold galleys in the main galley and in the lido galley, had 22 slotted fasteners around the opening on the interior food splash zone.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
21
|
|
Site:
Galley-Room Service
|
|
Violation:
The counter mounted hot water dispenser had less than a 100 mm (4-inch) clearance from the countertop.
|
|
Recommendation:
Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
|
|
|
Item No.:
22
|
|
Site:
Galley-Starboard Warewash
|
|
Violation:
The data plate for the rack-type dishwash machine stated a 130 second transit time for one rack, but the transit time was measured at 210 seconds by the inspector. Staff stated there may be two different settings for the machine with different rack speeds but provided no documentation.
|
|
Recommendation:
Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine?s data plate and other manufacturer?s instructions. Ensure a warewashing machine?s conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer?s specifications.
|
|
|
Item No.:
22
|
|
Site:
Galley-Starboard Warewash
|
|
Violation:
The final rinse manifold in the rack-type dishwash machine was making loud hissing noises during operation. Also, the spray nozzles on the bottom final rinse manifold were operating inconsistently. The spray nozzles would change from producing water in an effective spray pattern at one moment to producing pulses of steam the next moment. On at least two separate occasions the bottom spray nozzles were also observed not producing water at all for a minimum of ten second intervals during operation when the other final rinse spray nozzles were working. Pulses of steam were also sporadically observed coming from spray nozzles on both side final rinse manifolds.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewash
|
|
Violation:
The auxiliary rinse on the rack-type dishwash machine was not producing any water during operation. This was noticed by the inspector when the final rinse curtain was removed to measure the final rinse temperature. Also, although the final rinse temperature at the manifold was measured at 184°F and 181°F, the temperature at the plate surface did not reach 160°F.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewash
|
|
Violation:
The wash compartment of the rack-type dishwash machine was heavily soiled with food debris in several different areas, including all around the wash spray manifolds and on the curtain separating the wash and prewash compartments. Food debris was also observed on the machine surface where the final rinse curtains were hanged in place.
|
|
Recommendation:
Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
|
|
|
Item No.:
24
|
|
Site:
Galley-Warewash
|
|
Violation:
The chlorine solution in the 30 gallon bin that was used to dispense sanitizing solution to the white buckets in the crew galley and messes was measured above 200 ppm. The 30 gallon bin was about half filled with chlorine solution so additional water was added until the concentration was measured below 200 ppm.
|
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
24
|
|
Site:
Galley-Starboard Warewash
|
|
Violation:
The water temperature at the final rinse spray nozzles of the in-use rack-type dishwash machine was measured at 210°F, 206°F, and 196°F with a maximum registering thermometer. The water temperature in the final rinse manifold was measured above 200°F with two thermolabels. However, the final rinse temperature at the plate surface level was measured above 160°F by the inspector.
|
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
|
|
|
Item No.:
24
|
|
Site:
Galley-Warewash
|
|
Violation:
A combined seven different tests on the rack-type dishwash machine of the final rinse water temperature at the plate surface were taken between the inspector and crew members with results ranging between 145°F and 156°F. The temperatures were measured with a maximum registering thermometer at the plate surface through the front of the machine. Two temperatures were also taken at the final rinse manifold with a maximum registering thermometer with results of 184°F and 181°F.
|
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
|
|
|
Item No.:
25
|
|
Site:
Galley-Bakery
|
|
Violation:
The sanitizing wiping cloth was draped over the side sanitizing bucket.
|
|
Recommendation:
Restrict wiping cloths to the following: (1) Cloths used for wiping food spills are used for no other purpose; (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment; (3) Dry or wet cloths used with raw animal foods are kept separate from cloths used for other purposes. Wet cloths used with raw animal foods must be kept in a separate sanitizing solution; (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Officer's Mess
|
|
Violation:
The counter under the espresso machine was soiled with debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
30
|
|
Site:
Galley-Hot Galley
|
|
Violation:
Water was leaking from the handle on the handwash station faucet next to reach-in refrigerator 40428-D. This was immediately repaired.
|
|
Recommendation:
Keep handwashing facilities clean and in good repair.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-Walk-in Refrigerator #20
|
|
Violation:
Ice had accumulated on the bulkhead around the door leading to the walk-in freezer, especially at the top.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
34
|
|
Site:
Galley-Soup Station
|
|
Violation:
Water was leaking from the faucet handle on the front of the technical compartment between the soup kettle and braising pan and pooling on the deck. This was corrected.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
38
|
|
Site:
Galley-Patio
|
|
Violation:
A squeegee was stored to the right of the cleaning materials locker between the clean equipment storage racks.
|
|
Recommendation:
Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles.
|
|