Item No.:
19
|
|
Site:
Buffet-Windows Cafe
|
|
Violation:
Several of the spaces between the sneeze shields on the buffet line were wider than 1-inch and had food and equipment stored beneath. The widest gap was 3-inches on the port side of the buffet, and small containers of flax seeds and brown sugar with no lids were exposed.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
08
|
|
Site:
Galley-Windows Cafe Mini Galley
|
|
Violation:
The water supply line to the stacked combination ovens did not have a backflow prevention device. This was immediately corrected.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Windows Cafe Starboard Beverage Station
|
|
Violation:
The tongs for the self-service lemons were not protected under a sneeze shield or by other effective means.
|
|
Recommendation:
During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
|
|
|
Item No.:
37
|
|
Site:
Galley-Windows Cafe Warewash
|
|
Violation:
Condensation was accumulating on the deckhead inside the canopy hood on the soiled end of the conveyor dishwash machine during operation. The area was also excessively warm and the crew member working on the clean end of the machine was sweating. However, no clean equipment was impacted by the crew member's sweat.
|
|
Recommendation:
Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 4 Hot Galley
|
|
Violation:
The water line supplying the starboard combination oven was heavily soiled, especially by the backflow prevention device close by the deck.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
08
|
|
Site:
Galley-Deck 4 Hot Galley
|
|
Violation:
The backflow prevention device on the water supply line to the starboard combination oven was heavily soiled which blocked the atmospheric vents.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
29
|
|
Site:
Galley-Deck 4 Hot Galley
|
|
Violation:
The handwash station in the center of the hot galley was partially blocked by a yellow garbage can.
|
|
Recommendation:
Ensure handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 4 Warewash
|
|
Violation:
The water temperature of wash tank 1 on the in-use conveyor dishwash machine was measured at 155°F by both the inspector and crew. The data plate for the machine stated a required minimum temperature of 160°F for wash tank 1.
|
|
Recommendation:
Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine's data plate and other manufacturer's instructions. Ensure a warewashing machine's conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer's specifications.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 4 Chemical Locker
|
|
Violation:
Two soiled panini presses were stored on a deck stand between the chemical locker and the clean equipment storage locker. Staff stated these panini presses were staged here and not in the soiled-drop of area in the pot wash area so they would not be exposed to excessive water. However, the panini presses had been stored soiled in this location since the previous night.
|
|
Recommendation:
Ensure the panini presses are cleaned and sanitized after use.
|
|
|
Item No.:
39
|
|
Site:
Galley-Deck 5
|
|
Violation:
Three small fruit flies were observed by the technical compartment of reach-in refrigerator 5.5.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 5
|
|
Violation:
The technical compartment of reach-in refrigerator 5.5 was soiled with debris and standing water.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
16
|
|
Site:
Galley-
|
|
Violation:
A lexan container of raw hamburger patties on time control were on the side preparation table next to the grill without a 4-hour discard label.
|
|
Recommendation:
If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control. Ensure a 4-hour discard label is placed on a loose individual container of food that is not in a unit, even if the operation is open 4 hours or less.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
The plastic shatter-resistant wrap on three of the light bulbs above the hot line was peeling.
|
|
Recommendation:
Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
|
|
|
Item No.:
31
|
|
Site:
Galley-Aqualina/ Prime C
|
|
Violation:
A 30-gallon white bin filled with 100 ppm chlorine solution by the potwash area was not labeled with a sign identifying the contents
|
|
Recommendation:
Ensure working containers used for storing poisonous or toxic materials such as cleaners and sanitizers taken from bulk supplies are clearly and individually identified with the common name of the material.
|
|
|
Item No.:
19
|
|
Site:
Galley-Patio
|
|
Violation:
A container of all-purpose flour was stored in a hotel pan on the counter without a label identifying the contents.
|
|
Recommendation:
Ensure containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
|
|
|
Item No.:
33
|
|
Site:
Bar-Pool Bar
|
|
Violation:
The steel bars on the front bar shutters were corroded in several locations. When in operation, the front shutters were opened and held in place on the deckhead above the front part of the bar.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are corrosion resistant.
|
|
|
Item No.:
01
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Reporting
|
|
Violation:
The ship sent a 24-hour report on 8 March and a 4-hour report on 9 March before arrival to Miami. These reports were incorrect. Specifically, the 24-hour report had 6 reportable passenger cases, the 4-hour report had 5 reportable passenger cases, and the AGE log had 7 reportable passenger cases on 7 March.
|
|
Recommendation:
Ensure the master, medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port submits at least one standardized AGE report based on the number of reportable cases in the AGE log to VSP no less than 24 hours-but not more than 36 hours-before the vessel's expected arrival at the U.S. port. If the number of cases changes after submission of the initial report, submit an updated report no less than 4 hours before the vessel's arrival at the U.S. port. Ensure that the 4-hour update report contains a cumulative total count of the reported crew and passengers during the entire cruise, including the additional cases.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
The AGE log for the 21 February to 10 March voyage had no information in the underlying illness column for one passenger and one crew member.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person's name; (5) person's age; (6) person's sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
|
|
|
Item No.:
11
|
|
Site:
Medical-Crew Acute Gastroenteritis (AGE) Reporting
|
|
Violation:
The review of the AGE logs revealed that an engine repairman experienced AGE symptoms with an onset on 4 March at 1740 and reported to the medical center four days later on 7 March at 1604. The crew member worked and went to the crew mess all these days while symptomatic. A written disciplinary action was on file.
|
|
Recommendation:
When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Distant Point Charts
|
|
Violation:
There were two charts for 14 February and no chart for 15 February.
|
|
Recommendation:
Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Training
|
|
Violation:
Documented IPM training could not be found during the inspection for at least 13 individuals that were engaged in IPM inspections and treatments.
|
|
Recommendation:
Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Ensure the IPM plan includes provisions for training of crew members in charge of log completion. Record the time of the active monitoring inspections in the log.
|
|
|
Item No.:
16
|
|
Site:
Room Service-Back to Back In Stateroom Breakfast Menu
|
|
Violation:
The menu had a consumer advisory but no asterisk for the medium well steak preparation.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Ensure that disclosure is on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|