Cruise Ship: Oceania Marina Cruise Line: Oceania Cruises Inspection Date: 04/10/2017 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 27
Site: Galley-Deck 5 Bakery
Violation: The water generator next to the dough mixer was dripping rusty water from the bottom of the unit that was staining the deck. Staff stated the rust had accumulated in the housing due to condensation forming on the hot water line within the unit.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Provisions-Pulper Room
Violation: The waste pulper machine, located in the pulper room next to the butcher area had dirty water, rust and debris in the pulper basin. The water in the pulper had a rancid odor. Staff mentioned that this machine was not in use and had not been in use for some time.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 34
Site: Galley-Deck 5 Bakery
Violation: The water generator next to the dough mixer was dripping rusty water from the bottom of the unit that was staining the deck and making it hard to keep clean.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 22
Site: Provisions-Deck 4 Pot Wash
Violation: The potwash machine was labeled out of service since 5 February. Staff stated that parts were due to arrive 17 April.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Provisions-Fish Preparation Area
Violation: The sanitizing solution for the fish preparation area was cloudy. The area was in use during the inspection. Staff replaced the cloudy/dirty sanitizing solution with a clean one during the inspection.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 27
Site: Provisions-Pulper Room
Violation: The waste pulper machine, located in the pulper room next to the butcher area had dirty water, rust and debris in the pulper basin. The water in the pulper had a rancid odor. Staff mentioned that this machine was not in use and had not been in use for some time.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 38
Site: Provisions-Pulper Room
Violation: The waste pulper machine, located in the pulper room next to the butcher area had dirty water, rust and debris in the pulper basin. The water in the pulper had a rancid odor. Staff mentioned that this machine was not in use and had not been in use for some time.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 33
Site: Provisions-Deck 5 Bakery
Violation: The water generator next to the dough mixer was dripping rusty water from the bottom of the unit that was staining the deck and making it hard to keep clean.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 20
Site: Pantry-Deck 14 Tuscany
Violation: Three slotted screws were found on the ice thickness sensor attached to the cuber of the ice machine making the sensor area hard to clean.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 08
Site: Potable Water-Pipe Disinfection Records
Violation: The records for the eight pipe disinfections since the previous inspection included a statement that the final chlorine level after flushing was below 5 ppm but the actual ppm value was not recorded.
Recommendation: Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
Item No.: 19
Site: Other-Deck 4 I-95 by Stairs at Frame 126
Violation: A pallet of bottled water was staged in this area and a jacket had been placed on top. The jacket was immediately removed.
Recommendation: Protect food from contamination by storing the food: (3) Where it is not exposed to splash, dust, or other contamination.
Item No.: 08
Site: Potable Water-Spa Pedicure Chairs
Violation: Atmospheric vacuum breakers were installed on the potable water lines to the two pedicure chairs, but there were valves located downstream of the devices. The devices were under continuous water pressure, but were designed for noncontinuous pressure. In addition, the cross-connection control plan indicated that dual-check valves with atmospheric vents (Watts N9s) were installed on these water lines. Replacement of the devices began while the inspection team was still in the area.
Recommendation: Install a continuous pressure-type backflow preventer when a valve is located downstream from the backflow preventer.
Item No.: 18
Site: Buffet-Terrace Grill
Violation: In one of the upright refrigerators, a pan with a ground beef burger was stored above a pan of beef sirloin and two pans of fish. The pan with the ground beef burger was immediately moved below the fish and sirloin.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas.
Item No.: 33
Site: Galley-Waves Cage Dishwash Area
Violation: In between the two dishwash machines, the deck grout between two tiles was missing at the juncture with the stainless steel scupper. When the tiles were stepped on by the inspector, water bubbled up from beneath the tiles.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.