Cruise Ship: Amadea Cruise Line: Bernhard Schulte Cruise Services GmbH & Co. KG Inspection Date: 04/10/2017 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 15
Site: Bar-Harry's Bar Pantry
Violation: Brown flakes were noted on the outside of the ice cubes that were in the bin. The area was open for service and the machine was taken out of service.
Recommendation: Ensure food is safe and unadulterated.
Item No.: 27
Site: Galley-Deck 5 Dishwash Clean Storage
Violation: Two plastic plate covers stored in the clean dish storage area near the dishwash were visibly soiled.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 37
Site: Galley-Deck 8 Amadea Pantry
Violation: Excessive condensation collected on the deckhead over the two combination ovens. No dripping was observed.
Recommendation: Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 37
Site: Galley-Deck 8 Amadea Pantry Dishwash
Violation: Excessive condensation collected on the deckhead over the conveyor dishwasher, from the soiled end to the clean end. Constant dripping was observed on both the soiled end and the clean end. Clean dishes were impacted.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 28
Site: Galley-Deck 8 Amadea Pantry Dishwash
Violation: Excessive condensation collected on the deckhead over the conveyor dishwasher, from the soiled end to the clean end. Constant dripping was observed on both the soiled end and the clean end. At least 5 drops were observed dripping onto clean dishes as they exited the clean end of the machine.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 35
Site: Galley-Deck 8 Amadea Pantry Dishwash
Violation: The drain line for the handwash station in the clean dish storage area was directed over the scupper; however, the angle of the drain line was hitting the scupper in such a way that water quickly overflowed onto the deck tiles, causing standing water.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 22
Site: Galley-Deck 8 Amadea Pantry Dishwash
Violation: The far right nozzle on the final rinse manifold of the conveyor dishwasher was blocked; therefore, the final rinse was ineffective at sanitizing all dishes moving through the machine. There was no spray coming out of the far right nozzle at all; there was only a slow drip. This was immediately corrected.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 33
Site: Food Service General-Deck 5 Main Galley
Violation: Many areas of the deck in the main galley were in disrepair. Recessed grout was noted between deck tiles throughout the galley which caused standing water in many areas. In addition, excessive black debris, was noted along the coving at the juncture of the deck and bulkhead in many technical spaces.
Recommendation: Ensure light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 27
Site: Galley-Deck 5 Four Seasons Buffet
Violation: The bottom of beverage refrigerator 23 was excessively soiled with black and brown debris. The bottom rack was also soiled with white and brown debris. Beverage refrigerator 31 also was soiled with debris on the bottom. Various beverages were stored in the refrigerators.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 15
Site: Galley-Deck 5 Four Seasons Buffet
Violation: A previously opened bottle of water was found in refrigerator 18. Crew reported that open beverages are often labeled with a guest's table number, stored in the refrigerator, and re-served to the same guest at a subsequent dining meal; however, this bottle was not labeled.
Recommendation: After being served and in the possession of a consumer or being placed on a buffet service line, ensure food that is unused or returned by the consumer is not offered as food for human consumption.
Item No.: 27
Site: Galley-Deck 5 Four Seasons Buffet
Violation: The metal wine and beverage lockers were soiled with excessive dust and debris on the shelving, greater than one day's accumulation.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Deck 5 Four Seasons Buffet Coffee Station
Violation: Cords and hoses from the espresso machine were draped on the counter, causing it to be difficult to clean.
Recommendation: Elevate the cords above the counter.
Item No.: 27
Site: Galley-Deck 5 Four Seasons Buffet Coffee Station
Violation: Cords and hoses from the espresso machine were draped on the counter. The cords and hoses were excessively soiled with greater than a day's accumulation of debris.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 18
Site: Galley-Bakery
Violation: The deck mounted commercial mixer was soiled with clear brown liquid at the top of the rotating arm and on the metal grate around the top of the mixing bowl. The mixer was actively in use and crew could not determine the source of the liquid; however, it was clear to the inspector and crew that the liquid was not from the current operation of mixing egg whites. The unknown brown liquid dripped into the egg whites below. The egg whites were immediately discarded.
Recommendation: Discard a food that is unsafe or adulterated. Protect food from cross-contamination or other sources of contamination by the following methods: (3) Cleaning and sanitizing equipment and utensils.
Item No.: 19
Site: Galley-Deck 5 Bakery
Violation: The deck mounted commercial mixer was soiled with clear brown liquid at the top of the rotating arm and on the metal grate around the top of the mixing bowl. The mixer was actively in use and two drops of a clear brown liquid of an unknown source were observed dripping into the bowl of egg whites below. The food was not properly protected. The eggs whites were removed and discarded. Crew were unable to determine the source of the liquid which was not from the current operation of mixing egg whites.
Recommendation: During preparation, ensure unpackaged food is protected from environmental sources of contamination. Protect food from contamination that may result from a physical, chemical, biological origin.
Item No.: 33
Site: Galley-Deck 5 Hot Galley
Violation: Standing water accumulated below the two combination ovens. In addition, the deck was soiled with greater than a day's accumulation of soil, dust, food debris, and plastic debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 08
Site: Galley-Deck 5 Hot Galley
Violation: The backflow preventer on the left combination oven was excessively soiled with greater than a day's accumulation of debris, blocking the vents. The backflow preventer was located directly behind the soiled pot storage area for the three compartment sink.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 20
Site: Galley-Deck 5 Vegetable Preparation
Violation: Undercounter refrigerator 47 was out of service since 1 April.
Recommendation: Ensure equipment for cooling and heating food, and holding cold and hot food, is sufficient in number and capacity to maintain potentially hazardous food temperatures. Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines;
Item No.: 27
Site: Galley-Deck 5 Vegetable Preparation
Violation: Excessive standing water accumulated on top of the lid of a hotel pan containing herbs in undercounter refrigerator 48. Another smaller hotel tray of herbs was stored on top of the lid in the water.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Deck 5 Soup Station
Violation: The technical spaces between most kettles were leaking onto the deck below, causing standing water on the deck. The source of the water was unknown. Technical staff began work in the area immediately.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 38
Site: Galley-Deck 5 Soup Station
Violation: The potato peeler was out of service for 3-4 weeks awaiting a belt.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 33
Site: Galley-Deck 5 Soup Station
Violation: A round gap approximately 1 inch in diameter in the bulkhead to the right of the potato peeler led to the technical space and insulation behind the bulkhead.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 20
Site: Galley-Deck 5 Butcher
Violation: Upright refrigerator 52 was out of service since 12 March due to a broken display.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; Ensure equipment for cooling and heating food, and holding cold and hot food, is sufficient in number and capacity to maintain potentially hazardous food temperatures.
Item No.: 28
Site: Galley-Deck 5 Dishwash Clean Storage
Violation: Seven stacks of approximately 50 or more plastic plate covers were found in the clean dish storage area near the dishwash. The covers were wet inside. Crew agreed that the covers were stacked in a manner that prevented them from completely air drying. Crew reported the covers are usually air dried prior to stacking them in the manner they were found.
Recommendation: After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food. Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 37
Site: Galley-Deck 5 Dishwash
Violation: Condensation accumulated over the center of the flight type dishwash machine and was observed dripping onto the machine.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 33
Site: Galley-Deck 5 Dishwash
Violation: Standing water accumulated under the flight type dishwash machine. The source of the water was not determined.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 22
Site: Galley-Deck 5 Dishwash
Violation: The inspector was able to obtain a reading above 160°F at the plate surface prior to leaving the dishwash area; however, the readings were inconsistent. A curtain was removed to observe the final rinse, at which point it was noted the top horizontal final rinse manifold was not consistently spraying an even fan-like pattern from the side. Technical staff were called to assist with the evaluation of the machine. Upon further evaluation of the final rinse manifold, three of the left vertical final rinse spray nozzles were blocked, which prevented an effective spray pattern. The nozzles were unblocked after the finding. Additionally, top horizontal manifold did not consistently have a strong fan-like pattern.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 33
Site: Pantry-Deck 4 Crew Mess
Violation: There was a large gap in the deckhead over the dishwash machine between deckhead panels.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 20
Site: Buffet-Deck 4 Officer Mess
Violation: The coating on the shield inside the ice bin door was chipped, creating a difficult to clean surface.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition. Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections;
Item No.: 26
Site: Bar-Harry's Bar Pantry
Violation: Black debris was noted on the lowering arm of the evaporator of the ice machine. Additionally, debris was noted on the top of the cuber. The area was open for service and the machine was taken out of service.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 18
Site: Bar-Harry's Bar Pantry
Violation: Brown flakes were noted on the outside of the ice cubes that were in the bin. The area was open for service and the machine was taken out of service.
Recommendation: Discard a food that is unsafe or adulterated.
Item No.: 20
Site: Food Service General-Espresso Machines
Violation: Slotted fasteners were noted on the food contact surface of the espresso machines in Harry's and Copernicus. Crew noted all similar models of the espresso machine would have the same fasteners. Slotted fasteners are not easily cleanable. Cleanliness could not be evaluated as the areas were in operation and the machines were in use.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 27
Site: Bar-Copernicus
Violation: Excessive standing water was noted in undercounter refrigerator 10 which contained alcoholic beverages. The source of the water was not determined.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 10
Site: Recreational Water Facilities-Fecal/Vomit Accident Plan
Violation: The plan did not note the pH level to be maintained during disinfection. In addition, the plan did not specify that the scoop used to clean the vomit/fecal matter would be disinfected after use.
Recommendation: Ensure a fecal and vomit accident response procedure that meets or exceeds the procedure provided in Annex 13.8 is available for review during inspections.
Item No.: 33
Site: Pantry-Housekeeping Pantries 7 and 9
Violation: The deck in the pantries buckled, creating cracks and seams. Some cracks had been filled in with sealant, and some areas had worn away, creating difficult to clean areas. In addition, seams were noted along the juncture of the coving and the bulkhead in many areas of both pantries. Crew reported a work order had already been placed to address these areas.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 08
Site: Potable Water-Garbage Incinerator Room - Starboard - Aft
Violation: A hose used to clean the area was affixed with a shut off valve (i.e. spray nozzle) downstream of a hose bib vacuum breaker. This type of backflow preventer was not approved for continuous pressure.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (7) hose-bib connections; Install a continuous pressure-type backflow preventer when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Potable Water-Garbage Incinerator Room - Starboard - Aft
Violation: The potable water supply line at the right of the handwash sink in this room was not appropriately striped to indicate potable water.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Item No.: 06
Site: Medical-Microbiological Testing
Violation: Manufacturer's recommendations for E. coli testing were not followed. Staff stated they placed the water sample in the incubator for 30 minutes before conducting the 18 hour incubation test; however, the manufacturer's recommendations required the sample be pre-warmed using a water bath if the sample was not already at 33-38°C.
Recommendation: If water samples are collected and analyzed by the vessel for the presence of E. coli, analyze the samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Ensure test kits, incubators, and associated equipment are operated and maintained in accordance with the manufacturers' specifications.
Item No.: 06
Site: Potable Water-Far Point
Violation: The halogen analyzer chart recorder was recording approximately 0.5 ppm and the analyzer stated a free halogen residual level of 0.9 ppm. This was immediately corrected. The analyzer was accurate to the ship and inspector's potable water test kits.
Recommendation: Maintain the halogen analyzer-chart recorder properly and operate it in accordance with the manufacturer's instructions. Conduct a manual comparison test daily to verify calibration. Calibrate whenever the manual test value is greater than 0.2 ppm higher or lower than the analyzer reading.