|
|
|
Item No.:
08
|
|
Site:
Potable Water-Testable Devices
|
|
Violation:
The list of testable backflow prevention devices included some information on differential pressures recorded during tests conducted in May 2017, but the testing and documentation procedure could not be clarified by the staff. Specifically, 17 reduced pressure zone (RPz) backflow prevention devices had initial and final pressures along with a subtraction from these two pressure readings. Staff stated that the difference between these two pressures should not be above 0.5 psi to pass the test. However, there was no documentation on the device manufacturer's instructions or elsewhere indicating this kind of methodology. In addition, there was no documented differential pressure at the time the RPz started to leak from the intermediate relieve vents as required by the device manufacturer's 4-step testing procedure.
|
|
Recommendation:
Ensure the follow the manufacturer's instructions for testing each device and record differential pressures as required by the manufacturer to identify correct functioning or possible failure.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-ECR
|
|
Violation:
The backflow prevention device on the supply line to the espresso machine was not vented. Additionally, it was unclear if it was included on the list of backflow prevention devices since there were groupings by deck for these connections. Corrections started immediately.
|
|
Recommendation:
VSP only accepts vented devices. Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Thalasso
|
|
Violation:
The safety sign was not visible from the spa pool and was not located by the entrance. In addition, the sign informed users of the bather load of the swimming pool and the whirlpools but not of that one for the spa pool.
|
|
Recommendation:
Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Bather Loads
|
|
Violation:
The calculations for the bather loads were not available. Staff stated that will calculate and document these bather loads.
|
|
Recommendation:
Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow.
|
|
|
Item No.:
16
|
|
Site:
Bar-Barista
|
|
Violation:
At the buffet station during lunch service, one plate of sandwiches had no discard label and another plate of sandwiches had a discard label on the shelf under the plate. The time control service was 0500-22:30. Corrections started immediately.
|
|
Recommendation:
If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
|
|
|
Item No.:
16
|
|
Site:
Galley-Terrace
|
|
Violation:
During breakfast service and on the cold line counter, plates of cheese, herring, salmon, deli meats, cut melon, and others were not labeled with discard times and were on time control. Labeling started immediately.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard. Containers/plates of POTENTIALLY HAZARDOUS FOOD under time control and placed on preparation counters must be labeled with the discard time, even if the outlet is open less than 4 hours.
|
|
|
Item No.:
16
|
|
Site:
Bar-Terrace Café
|
|
Violation:
The milk on the front counter ice chest was on time control, but the time control plan could not be located. During the inspection, the plan that included the milk in this bar was found in the Terrace galley and a copy was going to be posted in the bar.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Terrace Buffet
|
|
Violation:
During breakfast service at the omelet station next to the ice cream station, 2 cups with mise en place ingredients were not completely protected from the side sneeze guard. This was immediately corrected.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
19
|
|
Site:
Buffet-Terrace Buffet
|
|
Violation:
At the ice cream stations, the dipper wells were not protected by sneeze guards. The distance between exposed dispensing utensils and where passengers stand was less than 1 meter (40 inches). Corrections started immediately.
|
|
Recommendation:
During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container; (2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon; (3) On a clean portion of the food preparation table or cooking equipment only if the in-use utensil and the food-contact surface of the food preparation table or cooking equipment are cleaned and sanitized at least every 4 hours; (4) In running water of sufficient velocity to flush particulates to the drain (if used with moist food such as ice cream or mashed potatoes); (5) In a clean, protected location (if the utensils, such as ice scoops, are used only with a food that is not potentially hazardous); or (6) In a container of water (if the water is maintained at a temperature of at least 57°C [135°F] and the container is frequently cleaned and sanitized). Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
19
|
|
Site:
Bar-Barista
|
|
Violation:
At the buffet station during breakfast service, pastries were under a sneeze guard but partially over the bulkhead-mounted light fixture that was covered with dust.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
19
|
|
Site:
Potable Water-ECR
|
|
Violation:
Five boxes of juices and one large bottle of water were stored directly on the deck and next to two large bottles of soap and a bucket with an amount of coffee debris and soiled water under the espresso machine table. Corrections started immediately.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
19
|
|
Site:
Potable Water-ECR
|
|
Violation:
The drain hose of the espresso machine was immersed in soiled coffee water inside a bucket under the table.
|
|
Recommendation:
Ensure drain lines from all fixtures, sinks, appliances, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice or drinks are indirectly connected to appropriate waste systems by means of an air gap or air break.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-
|
|
Violation:
There was one slotted fastener on the rough surface of the potato peeler. This was corrected.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
24
|
|
Site:
Buffet-Terrace Buffet (Outside Area)
|
|
Violation:
The solution in the sanitizing bucket had no chlorine. Corrections started immediately.
|
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
25
|
|
Site:
Buffet-Terrace Buffet (Outside Area)
|
|
Violation:
A wiping cloth was immersed in plain water.
|
|
Recommendation:
Restrict wiping cloths to the following: (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
|
|
|
Item No.:
27
|
|
Site:
Galley-Bakery
|
|
Violation:
The top and side of the oven was heavily soiled with dust. Corrections started immediately.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Buffet-Terrace Buffet
|
|
Violation:
During breakfast service, stacks of plates were upright at the food employee sides of the buffets. Although the stacks were behind the sneeze guard lines, they were located behind spaces of several inches between sneeze guards, being unprotected from the passengers in front of the plates. This was immediately corrected.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted. Protect eating utensils dispensed at a consumer self-service unit such as a buffet or salad bar from contamination.
|
|
|
Item No.:
28
|
|
Site:
Potable Water-ECR
|
|
Violation:
A closed bag of disposable spoons was on the deck under the espresso machine table next to a bucket with an amount of coffee debris and soiled water. Corrections started immediately.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
28
|
|
Site:
Galley-Dishwash
|
|
Violation:
The drying stage fan grill of the in-use flight-type dishwash machine was heavily soiled with dust accumulations. Dozens of plates were being washed, sanitized, and dried under this condition. Corrections started immediately.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
30
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
One of the two handwashing stations was not operational.
|
|
Recommendation:
Keep handwashing facilities clean and in good repair.
|
|
|
Item No.:
33
|
|
Site:
Potable Water-ECR
|
|
Violation:
The deck under the espresso machine table was not clean.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Walk-in Refrigerator 4.10
|
|
Violation:
The fan grills of the bulkhead-mounted cooling unit were heavily soiled with dust. Corrections started immediately.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Terrace Buffet (Outside Area)
|
|
Violation:
The waiter station had no coving on the back counter. In addition, the small front side areas of the front waiter station had no coving either.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
33
|
|
Site:
Bar-Barista
|
|
Violation:
At the buffet station, the bulkhead-mounted light fixture behind the sneeze guard was covered with dust.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
36
|
|
Site:
Galley-Terrace - Pizza Station
|
|
Violation:
The light film over the heating lamp on the counter was peeling. Also, the light inside the bottom part of the pizza oven was not working creating a very dark cooking area. Corrections started immediately.
|
|
Recommendation:
Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles. Replace the light bulb that was not working.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Training
|
|
Violation:
Records documented the inspection and acceptance of goods by the hotel inventory controller. IPM training could not be found for this person.
|
|
Recommendation:
Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Ensure the IPM plan includes provisions for training of crew members in charge of log completion. Record the time of the active monitoring inspections in the log.
|
|