Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 06/17/2017 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 31
Site: Other-Bridge Pantry
Violation: One coffee mug was stored on the counter top next to a container of chemical wipes.
Recommendation: Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 28
Site: Other-Bridge Pantry
Violation: One coffee mug was stored on the counter top next to a container of chemical wipes.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 06
Site: Potable Water-Far Point
Violation: On multiple dates (April 25, May 21, May 29, June 3, and June 6) the halogen analyzer chart recorder charts had a recording period of greater than 24 hours, exceeding by 2-4 hours.
Recommendation: Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system.
Item No.: 08
Site: Potable Water-Engine Room- Technical Fresh Water Service Boiler
Violation: The technical fresh water service boiler air gap was not twice the diameter of the delivery pipe.
Recommendation: Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
Item No.: 08
Site: Potable Water-Engine Room
Violation: Staff were using the blue/gray/blue striping to indicate technical water. These pipes were not distillate or permeate water. This was observed in the sewage collection room and after the backflow preventer supplying the technical potable water service boiler.
Recommendation: Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations.
Item No.: 08
Site: Ventilation-Deck 5-AC Ventilation Room 15
Violation: A single check vacuum breaker was installed on the hose tap, and the hose had a shut off valve installed.
Recommendation: Install a continuous pressure-type backflow preventer when a valve is located downstream from the backflow preventer.
Item No.: 43
Site: Ventilation-Deck 4- AC Ventilation Room 24
Violation: The air conditioning handling unit door was open with filter covering opening, Staff stated they were doing this to increase air flow (from inside ship) into unit. The unit not operating in accordance with design and construction requirements.
Recommendation: Operate air handling units according to initial design and construction requirements.
Item No.: 08
Site: Recreational Water Facilities-Pool Machinery Room
Violation: The air gaps on both the starboard and portside whirlpool/spas compensation tanks were not at least twice the diameter of the supply pipe of potable water.
Recommendation: Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
Item No.: 08
Site: Potable Water-Backflow Prevention Log
Violation: The cross connection backflow prevention log listed the incorrect backflow device for the two men's shower cabinets.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 08
Site: Potable Water-Backflow Prevention Log
Violation: The incorrect backflow prevention device was listed on the backflow prevention maintenance log for the men's toilet.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 08
Site: Recreational Water Facilities-Pool Machinery Room
Violation: The backflow prevention device installed on the pool machinery washing hose was corroded.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 07
Site: Potable Water-Disinfection of Potable Water Tank
Violation: On 13 January the ship had a positive E.coli sample from the shoreside sample of Corinto for the bunkering tap. Potable water tank 4C was disinfected for 3.5 hours with a halogen residual level of 50 ppm, instead of 4 hours.
Recommendation: Disinfect after potential contamination by increasing the free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.
Item No.: 07
Site: Potable Water-Disinfection of Potable Water Pipes
Violation: From the potable water replacement and disinfection records it was unclear if the jobs were planned or emergency. On November 22, 2016 the documentation stated a 20 meter pipe was disinfected from 8-15 at 200 ppm; it was unclear if this was the time of disinfection or amount of time the job took.
Recommendation: Disinfect after potential contamination by increasing the free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.
Item No.: 10
Site: Recreational Water Facilities-Chart Records
Violation: The chart records had a pH scale of 0-14, and was using this scale to document the chlorine concentration. The ship did not have dual-scale charts for pH and chlorine concentration.
Recommendation: Provide dual-range charts to document pH on log scale and halogen residual on concentration scale.
Item No.: 10
Site: Recreational Water Facilities-Filtration Records
Violation: The records for cartridge filter replacement were unclear. Staff were highlighting a date to show when filter replacement was conducted, but this was not written as a cartridge filter replacement.
Recommendation: Inspect cartridge or canister-type filters weekly for whirlpool spas and spa pools. For all other RWFs, inspect cartridge filters every 2 weeks, or in accordance with the manufacturer?s recommendation, whichever is more frequent. Inspect the filters for cracks, breaks, damaged components, and excessive organic accumulation. Change cartridge or canister-type filters based on the inspection results, or as recommended by the manufacturer, whichever is more frequent. Ensure at least one replacement cartridge or canister-type filter is available.
Item No.: 06
Site: Potable Water-Engine Room- Distribution
Violation: The back-up halogen pump did not start automatically when the primary pump was shut off. It was reported there was a power supply issue and air had accumulated in the chlorine line. The inspector verified this was corrected later during the inspection.
Recommendation: Install at least one backup halogen pump with an active, automatic switchover feature to maintain the free residual halogen in the event that the primary pump fails, an increase in demand occurs, or the low chlorine alarm sounds.
Item No.: 16
Site: Other-Bridge
Violation: Room service delivered coffee with a container of milk, which was stored on a counter. There was no record of time control management in this area.
Recommendation: If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
Item No.: 22
Site: Galley-Sanitizing bucket
Violation: During breakfast the water in the sanitizing bucket immediately to the left of the grill area contained cloudy and dirty water.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 24
Site: Galley-Three Compartment Sink
Violation: The crew member responsible for the final sanitizing step of the three compartment sink was observed allowing dwell times of 6 seconds, and not the minimum exposure time of 7 seconds. This area was in service during breakfast
Recommendation: Ensure a chemical sanitizer is used in accordance with the EPA-approved manufacturer?s label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
Item No.: 27
Site: Galley-Dishwash
Violation: A rack, which stored approximately 15 previously cleaned coffee cups, had drips of what appeared to be dried coffee adjacent to the clean cups. No cups were impacted. The tray was rewashed.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 36
Site: Buffet-Swimming Pool
Violation: The breakfast buffet set-up, adjacent to the pool, did not have sufficient lighting for the entire setup. The light intensities measured 165, 195, 175, and 145 lux during morning service. Items on the service included fruit boxed cereal, dairy and breads.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 27
Site: Galley-Hot Galley
Violation: The grease pan housing compartment, inside the previously cleaned flat grill, adjacent to the deep fat fryer contained a buildup of grease greater then day's accumulation.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 16
Site: Galley-Garde Manger
Violation: Items on temperature control, such as butter and yogurt, were stored in an undercounter refrigerator identified as on time control by the plan. Crew explained that the correct undercounter refrigerator was out of service and that these items were temporally moved into the adjacent cooler.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard. Ensure operations match the time control plan.
Item No.: 39
Site: Dining Room-Crew
Violation: One live fruit fly was on the bulkhead in this area. The area was not open.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 19
Site: Provisions-Fresh Vegetables
Violation: The soiled feet of a deck stand were resting stored against a palate of provisioned eggplant.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 21
Site: Provisions-Meat Freezer
Violation: A large amount of frozen condensate was observed on the air curtain leading to the butcher. This door was not used and blocked by provisions. The frozen condensate was also observed on two boxes of frozen mean adjacent to the door. Further investigation seemed to indicate that the door gasket had failed causing a buildup of frozen condensate inside the freezer.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 08
Site: Food Service General-Ice Machines
Violation: The backflow preventer on the potable water supply lines for most of the ice machines were noticeably corroded with rust stains that had dripped down the supply lines. At the time of inspection no active dripping was occurring.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 19
Site: Provisions-Meat Freezer
Violation: A large amount of frozen condensate was observed on the air curtain leading to the butcher. This door was not used and blocked by provisions. The frozen condensate was also observed on two boxes of frozen mean adjacent to the door. Further investigation seemed to indicate that the door gasket had failed causing a buildup of frozen condensate inside the freezer.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Provisions-Meat Freezer
Violation: A large amount of frozen condensate was observed on the air curtain leading to the butcher. This door was not used and blocked by provisions. The frozen condensate was also observed on two boxes of frozen mean adjacent to the door. Further investigation seemed to indicate that the door gasket had failed causing a buildup of frozen condensate inside the freezer.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 28
Site: Galley-Dishwash
Violation: A rack, which stored approximately 15 previously cleaned coffee cups, had drips of what appeared to be dried coffee adjacent to the clean cups. No cups were impacted. The tray was rewashed.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program