Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
There were no AGE logs. Staff stated that would only complete one if have they AGE cases.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP. Maintain a daily, standardized AGE surveillance log for each cruise by the master of the vessel, the medical staff, or other designated staff.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
There were no clinical specimen collection containers for bacterial agents.
|
|
Recommendation:
Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each), as well as a shipping container that meets the latest shipping requirements of the International Air Transport Association (IATA) and U.S. Department of Transportation for Biological Substances, Category B designated shipments (or higher). Ensure the vessel maintains the appropriate labels and markings required for shipping Biological Substances, Category B shipments. Ensure the vessel maintains appropriate refrigerant materials to keep clinical specimens cool. (see Annex 13.4 of the VSP 2011 Operations Manual.)
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Microbiologic Monitoring
|
|
Violation:
Staff had been collecting and analyzing at least 4 samples a month but always from the same locations.
|
|
Recommendation:
Collect and analyze a minimum of four potable water samples per month for the presence of E. coli. Collect samples from the forward, aft, upper, and lower decks of the vessel. Change the sample sites each month so that all of the potable water distribution system is effectively monitored. Conduct follow-up sampling for each positive test result.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunkering Hoses
|
|
Violation:
During active bunkering, hoses were on the road of the pier in puddles of water. It was discovered that the connected hoses had different holes where water was leaving the hoses and could come in too. After the finding, the hoses were elevated above the road.
|
|
Recommendation:
Construct all hoses, fittings, and water filters used in the bunkering of potable water of safe, easily cleanable materials approved for potable water use and maintain them in good repair.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Training
|
|
Violation:
There was no training documented for anyone involved with IPM. Staff stated that they received training but there was no record about it.
|
|
Recommendation:
Document the training of the pest-control personnel.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Rat Guards
|
|
Violation:
Most of the rat guards on the mooring lines did not surround the lines completely. Also, both rat guards on the forward lines were blown by the wind, making them ineffective to prevent the passage of vermin crawling along the lines from the pier to the ship.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Follow Up Inspections
|
|
Violation:
No follow-up actions were documented.
|
|
Recommendation:
When pests are noted during an inspection, ensure the log includes action taken and follow-up inspection results.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Active Monitoring Inspections
|
|
Violation:
The time of the active monitoring inspections was not recorded.
|
|
Recommendation:
Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Ensure the IPM plan includes provisions for training of crew members in charge of log completion. Record the time of the active monitoring inspections in the log.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunker Stations
|
|
Violation:
The cap could touch the deck when hanging from the chain. This was corrected.
|
|
Recommendation:
Ensure the potable water filling line has a screw cap fastened by a noncorroding cable or chain to an adjacent bulkhead or surface in such a manner that the cap cannot touch the deck when hanging free. Ensure the hose connections are unique and fit only the potable water hoses.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Hose Locker
|
|
Violation:
There were three bunkering hoses stored uncapped or uncoupled. This was corrected.
|
|
Recommendation:
Ensure potable water hoses are rolled tight with the ends capped, on reels, or on racks, or with ends coupled together and stowed in potable water hose lockers.
|
|
|
Item No.:
28
|
|
Site:
Other-Engine Room
|
|
Violation:
A large cooler was stored wet and on the deck next to ventilation unit 103. Staff stated that it was used by the crew. In addition, there were four carbonators and a tray with glasses under the ventilation unit.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunkering Chart
|
|
Violation:
The bunkering chart was recording chlorine and pH levels with a 30 minute discrepancy and thus not accurate.
|
|
Recommendation:
Maintain accurate records of production and bunkering monitoring aboard for 12 months and ensure these records are available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Permeate Lines
|
|
Violation:
The permeate lines were striped blue/green/blue, indicating potable water, before the chlorine injection point. This was corrected.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
03
|
|
Site:
Potable Water-Reverse Osmosis
|
|
Violation:
There were no means to adjust the pH for water produced by the reverse osmosis plant.
|
|
Recommendation:
Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
There was no equipment for pH control for distribution water system. Most of the distant point charts documented a pH close to 11.
|
|
Recommendation:
Construct and install all distribution water system chemical injection equipment in accordance with recommended engineering practices.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Laundry
|
|
Violation:
The space between the potable water pipe transferring to the laundry tank was not twice the diameter of the delivery pipe.
|
|
Recommendation:
Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Laundry
|
|
Violation:
The outside vent for potable water tank 1P had a large gap along the side that was not enough to prevent the tank from contamination.
|
|
Recommendation:
Protect potable water tanks, vents, and overflows from contamination.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Distant Point Charts
|
|
Violation:
The chart of the day of the inspection documented chlorine readings above 5.00 ppm since 7:40 am, time when the chart was changed. These high levels were documented nonstop since 8:00 pm of the prior night. At least 20 charts documented several hours of chlorine levels above 5.00 ppm.
|
|
Recommendation:
Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen readings at the distant point analyzer. Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel. Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system.
|
|
|
Item No.:
04
|
|
Site:
Potable Water-Distribution System Halogen Residual
|
|
Violation:
The chlorine residual at the far point analyzer was measured at 9.08 ppm by the inspector's test kit, while the analyzer was reading 14.48. The chart recorder in the bridge was measuring 5.11 ppm.
|
|
Recommendation:
Provide continuous halogenation of the potable water system using halogenation injection equipment and maintain a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
|
|
|
Item No.:
05
|
|
Site:
Potable Water-Distribution System Halogen Residual
|
|
Violation:
The free chlorine residual measured by the analyzer was not ± 0.2 MG/L (ppm) of the free residual chlorine measured by the manual test. The chlorine residual at the far point analyzer was measured at 9.08 ppm by the inspector's test kit, while the analyzer was reading 14.48. The chart recorder in the bridge was measuring 5.11 ppm.
|
|
Recommendation:
Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
44
|
|
Site:
Potable Water-Distribution System Halogen Residual
|
|
Violation:
The chlorine residual at the far point analyzer was measured at 9.08 ppm by the inspector's test kit, while the analyzer was reading 14.48. The chart recorder in the bridge was measuring 5.11 ppm. Potable water tank 2P had chlorine levels of 9.33 ppm and was the tank being in use. The other 3 tanks had chlorine levels around 2.00 ppm. It was unclear why this tank was still being used when the distant point analyzer was reading levels of more than 5.00 ppm for about 16 hours and only corrective actions were implemented when the issue was raised by the inspectors. Staff also stated that the alarm sounded on the bridge informing them of the high levels but not immediate actions were taken. During the final meeting, a distribution chlorination station was presented to the inspectors by the Captain and it was unclear the reason why the persons in charge of the potable water system stated before that there was no chlorine dosing after the water was put in the tanks.
|
|
Recommendation:
Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank 1S Sample Cock
|
|
Violation:
The sample cock did not work. Staff had to unscrew a screw to take a sample from the tank.
|
|
Recommendation:
Ensure potable water tanks have labeled sample cocks that are turned down. Identify the sample cocks with the appropriate tank number.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunkering Pretest
|
|
Violation:
There were 5 times in June that no pretest chlorine levels were documented.
|
|
Recommendation:
Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Secondary Standards
|
|
Violation:
The secondary standards for the test kit used for checking halogen levels expired on May 2016.
|
|
Recommendation:
Ensure the halogen test kit used to calibrate the halogen analyzer is accurate to within 0.2 mg/L (ppm) for halogen and graduated in increments no greater than 0.2 mg/L (ppm) in the range of free residual halogen normally maintained in the potable water system. Ensure all reagents used with the test kit are not past their expiration dates. Where available, maintain appropriate secondary standards onboard for electronic test kits to verify test kit operation.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Annual Testing
|
|
Violation:
Records for annual testing for the testable devices were not available.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenance Records
|
|
Violation:
Records dated March 10, 2017 documented that tanks 1P and 1S were disinfected on March 10, 2014 and put in service on March 11, 2014. Also, records dated March 12, 2017 documented that tanks 2P and 2S were disinfected on March 12, 2014 and put in service on March 13, 2014.
|
|
Recommendation:
Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service.
Inspect, clean, and disinfect potable water tanks during dry docks and wet docks, or every 2 years, whichever is less.
|
|
|
Item No.:
36
|
|
Site:
Galley-Walk-in Refrigerator
|
|
Violation:
The light intensity was very low at the two corners next to the door. Food was stored in these areas.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
15
|
|
Site:
Galley-Walk-in Refrigerator
|
|
Violation:
Two large containers of fruit smoothie were found full of mold on the lower shelf of the left shelving stands. These were discarded.
|
|
Recommendation:
Ensure food is safe and unadulterated.
|
|
|
Item No.:
15
|
|
Site:
Galley-Water
|
|
Violation:
During lunch service, the chlorine levels in the water used for ice, stocks, lobster slurry, and other foods were tested and measured between 9 ppm and above 10 ppm. Ice, rice, and a stock were discarded.
|
|
Recommendation:
Ensure food is safe and unadulterated.
|
|
|
Item No.:
33
|
|
Site:
Galley-Walk-in Freezer
|
|
Violation:
The deck, bulkheads, and deckhead had ice accumulations.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The final rinse gauge of the in-use undercounter warewasher measured around 12 psi. The data plate required a pressure of 15-25 psi.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The final rinse center upper arm nozzle of the in-use rack-type warewasher was clogged. This was corrected.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck Oven
|
|
Violation:
The top panel was heavily soiled.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
22
|
|
Site:
Galley-Sanitizing Solutions
|
|
Violation:
Three buckets and the third compartment of the 3-compartment sink had cloudy sanitation solutions.
|
|
Recommendation:
Ensure the wash, rinse, and sanitize solutions are maintained clean.
|
|
|
Item No.:
08
|
|
Site:
Galley-Hood Cleaning Cabinet
|
|
Violation:
The backflow preventer was continuously leaking from the intermediate vent, indicating a possible failure.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
16
|
|
Site:
Galley-Pantry Undercounter Refrigerator
|
|
Violation:
Four trays of cut melon had a temperature of 46-47°F. These were immediately sent to the blast chiller.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
|
|
|
Item No.:
21
|
|
Site:
Galley-Hot Galley
|
|
Violation:
A whisk approximately 3 feet long was being used in one of the kettles and had an open ended handle, making it difficult to clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
36
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The light intensity around the ice machine was less than 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The top panel of the liquor cabinet was heavily soiled with grease and debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
40
|
|
Site:
Galley-Hot Galley
|
|
Violation:
A dead fly was in the greasy surface on top of the liquor cabinet.
|
|
Recommendation:
Remove dead or trapped insects, rodents, and other pests from control devices and the vessel at a frequency that prevents their accumulation or decomposition or the attraction of other pests.
|
|
|
Item No.:
16
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The canape' service that happens every night had no time control plan. This was corrected.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
19
|
|
Site:
Dining Room-Main
|
|
Violation:
One of the two self-closing chafing dishes was malfunctioning, leaving the lid open for a long time.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
16
|
|
Site:
Dining Room-Main
|
|
Violation:
At the buffet table, the consumer advisory for the cold smoked salmon was not specific to the salmon and did not indicate that this food was served raw or undercooked.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Main
|
|
Violation:
The deck at the buffet table was carpeted.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
19
|
|
Site:
Dining Room-Main
|
|
Violation:
The self-service oatmeal kettle was not self-closing and was not used under a sneeze guard.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Main
|
|
Violation:
The soup kettle waiter station on one of the tables close to the entrance to the galley was on carpet.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
Above the hot line, there was more than a day's accumulation of food debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
The light intensity around the ice machine was less than 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
The technical space and the top panel of the upright refrigerator were heavily soiled.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Cliff Rock Bar and Grill
|
|
Violation:
The buffet counter and waiter station had carpeted and stained deck.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Cliff Rock Bar and Grill
|
|
Violation:
The kettle used for self-service oatmeal and soup was not self-closing and not used under sneeze guards.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
22
|
|
Site:
Bar-Seascape Tavern
|
|
Violation:
The final rinse gauge of the in-use undercounter warewasher measured around 12 psi. The data plate required a pressure of 15-25 psi.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
19
|
|
Site:
Galley-Walk-in Freezer
|
|
Violation:
The food storage was excessively cluttered and overly full. Staff stated that 8 days before they provisioned in big quantities. Boxes were compressed and compacted into each other, trays of prepared food were on top and in between boxes. Most food could not be inspected and some of the food was almost touching the bulkheads and deckhead. There were accumulations of ice on the deck, bulkheads, and deckhead.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|