|
|
|
Item No.:
26
|
|
Site:
Pantry-Lido Coffee Pantry
|
|
Violation:
The espresso machine dispenser was soiled with debris. Staff stated the machine had not been used recently. The machine was cleaned before the end of the inspection.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
21
|
|
Site:
Pantry-Lido Coffee Pantry
|
|
Violation:
The cords from the coffee maker were draped across the counter. This was immediately corrected. This area was clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Pantry-Lido Glass Pantry
|
|
Violation:
The cords from the juice machine and the water dispenser were draped across the counter. This was immediately corrected. These areas were clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Portside Beverage Station
|
|
Violation:
The cords from the espresso machine were draped across the counter. This was immediately corrected. This area was clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
16
|
|
Site:
Galley-Mamsey's
|
|
Violation:
The cooling log for the liver pate stated the temperature was 64°F at 20:19. A second entry for the liver pate stated the temperature was 37°F at 20:10. Staff stated the second entry should have been recorded as 37°F at 22:10. Previous entries of the same product had times similar to what staff stated were the correct times for the product.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
29
|
|
Site:
Galley-Woman's Toilet Room
|
|
Violation:
The door to the woman's toilet room was locked during the inspection. This area was in active use. This was immediately corrected. The door to the male's toilet room, immediately across from the woman's, was unlocked during the inspection.
|
|
Recommendation:
Ensure toilet facilities intended for use by galley personnel are not locked when the galley is in service.
|
|
|
Item No.:
16
|
|
Site:
Galley-Chef's Table
|
|
Violation:
The service line was not labeled as on time control. This was immediately corrected.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
26
|
|
Site:
Galley-Cold Galley
|
|
Violation:
The mixing arm of the mixer was soiled. It was immediately cleaned.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Cold Galley
|
|
Violation:
Water was dripping from the mixer onto the counter. Staff stated the mixer had been cleaned the previous night and the water may have pooled inside from the cleaning process.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
19
|
|
Site:
Galley-Pastry
|
|
Violation:
A rolling bin of all purpose flour did not have a label. The bin was labeled.
|
|
Recommendation:
Ensure containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
|
|
|
Item No.:
33
|
|
Site:
Galley-Potwash
|
|
Violation:
Water was pooling in the light shield over the clean storage rack.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Dishwash
|
|
Violation:
Condensate was dripping from the deckhead and the outlet of the conveyor dishwash machine. The area was in active use, but no dishes were impacted.
|
|
Recommendation:
Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
33
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
Water was dripping from the deckhead onto the clean side of the glass wash. The machine was not in use.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
Water had collected in the light shield next to the clean side of the glass wash.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
18
|
|
Site:
Galley-Chef's Table Pantry
|
|
Violation:
An employee used one of two plastic single-use utensils to taste food. The employee then walked to a utility sink and rinsed the unused utensil. The employee went back to the food prep area and placed both spoons on the counter. The utensil used to taste the food still had food residue on it. Management instructed the employee to dispose of the spoons, clean the counter, and wash their hands.
|
|
Recommendation:
Ensure tasting utensils are properly discarded after use.
|
|
|
Item No.:
21
|
|
Site:
Galley-Beverage Station
|
|
Violation:
The cords from the juice machine were draped on the counter.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
24
|
|
Site:
Galley-Dishwash Machine
|
|
Violation:
At the final rinse manifold, the crew member thermometer's read 172°F and 175°F. The inspector's thermometer read 172°F and 169°F. At plate surface, the inspector's thermometer read 151°F. The machine displayed a final rinse temperature of 165°F. The machine was in use at the time of the inspection. The inspector came back later in the inspection. At the manifold, the crew member's thermometer read 178°F, 172°F, and 175°F. At the plate surface, the temperature measured 163°F. The inspector verified the machine was sanitizing at the proper temperature before the end of the inspection.
|
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
|
|
|
Item No.:
16
|
|
Site:
Bar-Living Room Bar
|
|
Violation:
The counter-mounted food display case and the undercounter refrigerator were not labeled as on time control.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
*
|
|
Site:
Potable Water-Bunkering and Production Chart Records
|
|
Violation:
The ship used manual testing for its main method of record keeping. However, the bunkering and production halogen and pH analyzer recorder utilized charts with one single range of 0 - 10 for both pH and halogen concentration readings. These single range charts were used from 19 Aug 2017 until 13 Nov 2017. Additionally, charts prior to 19 Aug 2017 had one single range from 0 - 100 for both pH and halogen concentration readings. These charts did not have a separate scale to differentiate between halogen recordings and pH recordings. The engineer provided a purchase order, dated 14 Sept 2017, to show new charts with two scales have been ordered.
|
|
Recommendation:
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunkering and Production Chart Records
|
|
Violation:
The ship manually conducted halogen concentration and pH recordings. The ship provided the manual logs, which showed production of water beginning on 31 Oct 2017 at 13:25 and ending on 1 Nov 2017 at 12:10. The manual logs showed the next production of water began on 3 Nov 2017 at 17:35 and ended on 4 Nov 2017 at 05:30. The analyzer-chat records did not record readings for these dates. The analyzer-chart records showed production of water began on 2 Nov 2017 at 03:10 and ended at 11:30. These two records did not match.
|
|
Recommendation:
Maintain accurate records of production and bunkering monitoring aboard for 12 months and ensure these records are available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Water Testing Kit
|
|
Violation:
The onboard test kit was not accurate within 0.2 for pH. When tested, ship showed the test kit was 0.23 and 0.25 out of calibration for pH.
|
|
Recommendation:
Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity. Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF. Ensure test kits for pH are accurate to within 0.2. Ensure all reagents are not past their expiration dates.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Reverse Osmosis System
|
|
Violation:
There was a pipe marked blue/green/blue that was attached to the backwash system of the reverse osmosis unit. Staff could not distinguish what the line was used for and stated that the backwash system was being re-done. Staff were unsure if the line was being used. The inspector could not find a backflow device.
|
|
Recommendation:
Protect the potable water system against backflow or other contamination by backflow prevention devices or air gaps. Ensure the permeate lines and distillate lines directed toward the potable water system are also protected.
|
|
|
Item No.:
27
|
|
Site:
Galley-Cold Galley
|
|
Violation:
Water was dripping from the mixer onto the counter. Staff stated the mixer had been cleaned the previous night and the water may have pooled inside from the cleaning process.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash Machine
|
|
Violation:
At the final rinse manifold, the crew member thermometer's read 172°F and 175°F. The inspector's thermometer read 172°F and 169°F. At plate surface, the inspector's thermometer read 151°F. The machine displayed a final rinse temperature of 165°F. The machine was in use at the time of the inspection. The inspector came back later in the inspection. At the manifold, the crew member's thermometer read 178°F, 172°F, and 175°F. At the plate surface, the temperature measured 163°F. The inspector verified the machine was sanitizing at the proper temperature before the end of the inspection.
|
|
Recommendation:
|
|