|
|
|
Item No.:
08
|
|
Site:
Galley-Port Beverage Station
|
|
Violation:
The starboard side backflow preventer was excessively soiled around the vents.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Laundry Room
|
|
Violation:
The backflow devices for both hot and cold water located in the laundry room were corroded. They were replaced during the inspection. Disinfection procedures were followed.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Main Pool Room
|
|
Violation:
The backflow prevention device on the cleaning hose in the pool room was corroded and rusty. It was replaced during the inspection.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
On 3 DEC, tomato sauce was cooled from 142°F at 1635 to 62°F at 1825 but completed cooling was not recorded. Crew reported that the food went directly to service, but there were no notes on the cooling log to document this.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
16
|
|
Site:
Galley-
|
|
Violation:
Cannelloni was on temperature control in the undercounter cabinet and was dated 11 DEC. Upon inspection of the cooling logs, the tomato sauce in the cannelloni was cooled on 10 DEC.
|
|
Recommendation:
Ensure refrigerated, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. Ensure refrigerated, potentially hazardous, food ingredients or a portion of a refrigerated, potentially hazardous, food that is subsequently combined with additional ingredients or portions of food retains the date marking of the earliest or first-prepared ingredient.
|
|
|
Item No.:
16
|
|
Site:
Bar-Coffee Corner
|
|
Violation:
The previously opened container of whipping cream in the upper cold drawer was measured by the inspector at 46-47°F with a sensitive tip thermometer. The crew measured the same temperature. The container was opened approximately 1.5 hours earlier had a 7 day discard label, but the cooling process was not being monitored. Crew reported that the container had previously been refrigerated prior to opening. The cream was discarded.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Coffee Corner
|
|
Violation:
Muesli, parfait, yogurt, and cottage cheese were on time control that ended at 9:30 AM. At 9:35 AM, the products were still out for service.
|
|
Recommendation:
If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food Is discarded within 4 hours of placement on time control.
|
|
|
Item No.:
16
|
|
Site:
Galley-Deck 5 Cold Galley Walk-In Room 247
|
|
Violation:
Two trays for chicken salad sandwiches had a production day of 12 DEC, but the cooling logs documented that the chicken was cooked and cooled on 11 DEC. This was corrected.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. Ensure refrigerated, potentially hazardous, ready-to-eat food ingredients or a portion of a refrigerated, potentially hazardous, ready-to-eat food that is subsequently combined with additional ingredients or portions of food retains the date marking of the earliest or first-prepared ingredient.
|
|
|
Item No.:
18
|
|
Site:
Galley-Deck 5 Cold Galley Walk-In Room 247
|
|
Violation:
Two trays of smoked salmon sandwiches were wrapped in plastic and stored over trays of chicken roll sandwiches, ham, garlic, bread, and other food. This was immediately corrected.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another.
|
|
|
Item No.:
19
|
|
Site:
Medical-Doctor's Office
|
|
Violation:
Three cases of water used for passengers and crew were stored on the deck.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck. Protect food from contamination that may result from a physical, chemical, biological origin.
|
|
|
Item No.:
20
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The left combination oven was out-of-service since the morning of the inspection.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 5 Hot Galley
|
|
Violation:
The deep fryer had been out-of-service for approximately 2 weeks. Crew had recently worked on the equipment and while welding, a hole was made in the base of the fryer.
|
|
Recommendation:
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections. Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 5 Port Ice Crusher
|
|
Violation:
The ice chute was separated from the crusher, which left the chute and food-contact surface of the crusher exposed to the technical space. Ice and water dripped down below and collected in the technical space, which created a sludge on the bottom of the technical space.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
|
|
|
Item No.:
21
|
|
Site:
Galley-Prime 7
|
|
Violation:
The sticker on the nonfood-contact side of the portable induction cooktop was peeling, sticky, and soiled.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 5 Dishwash Starboard
|
|
Violation:
The left nozzle of the final rinse spray arm of the rack-type conveyor glasswash machine was not producing an effective spray pattern. Excessive water was spraying out of the end of the spray arm where no nozzle was located. Upon inspection, it was determined the rubber end of the upper final rinse arm was not properly in place. Crew immediately began corrective action.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
22
|
|
Site:
Buffet-Veranda Buffet
|
|
Violation:
The solution in the sanitizing bucket was soiled with a large piece of food debris and the sanitizing solution measured less than 50ppm. The solution was immediately changed.
|
|
Recommendation:
Ensure the wash, rinse, and sanitize solutions are maintained clean.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The rack-type conveyor dishwash was leaking water which pooled on the deck.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 5 Potwash
|
|
Violation:
The frontloading warewash machine had been out-of-service since the morning of the inspection because it did not reach the appropriate wash temperature.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
22
|
|
Site:
Pantry-Deck 9 Pantry
|
|
Violation:
Two upright previously cleaned glasses, three trays of desserts to be discarded, and two soiled trays were on the clean side counter. In addition, a cart of dirty dishes and four bowls of previously used peanuts was resting against/under the clean dry rack. The area was cleaned during the inspection.
|
|
Recommendation:
Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 5 Port Dishwash
|
|
Violation:
The rack-type conveyor dishwash was out-of-service since the morning of the inspection due to an issue with the solenoid that caused water to overflow. The rack-type glasswash machine was out-of-service since the morning of the inspection due to an issue with the final rinse. Crew were working on fixing the machines and reported during the close-out meeting that the machines were fixed.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
24
|
|
Site:
Buffet-Veranda Buffet
|
|
Violation:
The solution in the sanitizing bucket was soiled with a large piece of food debris and the sanitizing solution measured less than 50ppm. The solution was immediately changed.
|
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm);
|
|
|
Item No.:
26
|
|
Site:
Galley-Crew Water Fountain
|
|
Violation:
There was pink debris on the mouth guard.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Bar-Coffee Corner
|
|
Violation:
Two containers of soy milk in the lower cold drawer were soiled with a dark debris on the cap and the top of the carton near the pouring spout. These were immediately sanitized.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Prime 7 Ice Machines
|
|
Violation:
The Prime 7 ice machine had pink debris and a dark debris on the center column.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 5 Dishwash Storage Closet
|
|
Violation:
Approximately 20 plastic bins were stacked in the clean area along with clean items. They were wet nested and not inverted. Crew reported they were previously cleaned and had not air dried appropriately, but upon further inspection, some bins were visibly soiled with food debris. The bins were immediately sent to be washed.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 5 Starboard Corridor Storage Room - FSD 05.05.47
|
|
Violation:
Three waffle makers were stored with a thick grease debris on the food-contact and nonfood-contact surfaces. Crew reported this area was for excess equipment that wasn't frequently used, but one soiled waffle maker was still hot from service. Crew immediately began removing the equipment to empty the room.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Pantry-Deck 11 Pantry
|
|
Violation:
The water spray arm of the ice machine was soiled with a pink substance along the length and near the main base. The ice machine was closed for cleaning immediately.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 5 Dishwash Storage Closet
|
|
Violation:
Approximately 20 plastic bins were stacked in the clean area along with clean items. They were wet nested and not inverted. Crew reported they were previously cleaned and had not air dried appropriately, but upon further inspection, some bins were visibly soiled with food debris. The bins were immediately sent to be washed.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The left combination oven was out-of-service since 6AM the morning of the inspection. Crew reported that the galley was cleaned after breakfast, and the inspection occurred during the lunch service. There were large chunks of food debris on the bottom of the oven.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 5 Starboard Corridor Storage Room - FSD 05.05.47
|
|
Violation:
Three waffle makers were stored with a thick grease debris on the food-contact and nonfood-contact surfaces. Crew reported this area was for excess equipment that wasn't frequently used, but one soiled waffle maker was still hot from service. Crew immediately began removing the equipment to empty the room.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 5 Port Ice Crusher
|
|
Violation:
The ice chute separated from the crusher, which left the chute and crusher exposed to the technical space. Ice and water dripped down below and collected in the technical space, which created a sludge on the bottom of the technical space.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Prime 7
|
|
Violation:
The sticker on the nonfood-contact side of the portable induction cooktop was peeling, sticky, and soiled.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Food Service General-Ice Machines
|
|
Violation:
Multiple ice machines were found with a white foam insulation around the evaporator. This material was difficult to clean, and brown debris was found in the technical areas. Many had green debris on the foam in the technical area. Crew reported this to be oxidation. Ice machines found with the foam with brown debris include: 1) Signatures galley; 2) Pool Bar pantry; 3) Prime 7 galley; 4) two main galley starboard aft machines; 5) port main galley; and 6) crew galley. This foam was noted on the previous inspection report, and at the time crew noted the machines may be replaced during the April 2018 Dry Dock. The inspector requested paperwork to demonstrate a plan for the machine replacement, but crew were unable to produce such documentation. The engineering staff explained that they had replaced many of the foam insulations, but that they had not replaced the entire unit. It was apparent that the foam was not what was originally installed, that the crew were cleaning the area, but that the foam was not conductive to maintaining a clean environment.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Buffet-Officer Mess
|
|
Violation:
Excessive condensation collected under the overshelf and the sneeze shield of the in-use bains-marie during service. One half-pan of the bains-marie was not covered, which allowed steam to escape. Dripping was noted onto the counter but not onto the food. Crew immediately removed food to be discarded, and began cleaning the area.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; and (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
28
|
|
Site:
Galley-Deck 5 Starboard Corridor Storage Room - FSD 05.05.47
|
|
Violation:
The room behind Fire Safety Door 05.05.47 was not properly constructed to standards for food equipment storage. The deck was not smooth and easily cleanable, and it was soiled with greater than a day's accumulation of debris. The deckhead was not smooth and easily cleanable; there were exposed pipes and wires similar to that of a technical space. Multiple pieces of clean and soiled food equipment were stored in this area including induction plates, utensils, a hand mixer, and others. Three waffle makers were stored with a thick grease debris on the food-contact and nonfood-contact surfaces. Crew reported this area was for excess equipment that wasn't frequently used, but one soiled waffle maker was still hot from service. A trolley was labeled 'knife locker' and a soiled scale was stored in this trolley. There were many new utensils such as knives stored in this trolley. Holiday decorations including ornaments and wooden houses for gingerbread houses were stored in this area against food equipment. A stack of plastic boxes was stored upright in this area, instead of inverted, so it was difficult to determine if they boxes were previously cleaned or not. Crew immediately began removing the equipment to empty the room.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; and (2) in a location where they are not exposed to splash, dust, or other contamination. Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Galley-Deck 5 Port Dishwash
|
|
Violation:
The shelves of the clean storage rack were excessively soiled with dry food debris. Dishwasher utensil racks and previously cleaned plate covers were stored in this area.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; and (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
28
|
|
Site:
Galley-Deck 5 Dishwash Storage Closet
|
|
Violation:
Approximately 20 plastic bins were stacked in the clean area along with clean items. They were wet nested and not inverted. Crew reported they were previously cleaned and had not air dried appropriately, but upon further inspection, some bins were visibly soiled with food debris. The bins were immediately sent to be washed.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Pantry-Deck 9 Pantry
|
|
Violation:
Two upright previously cleaned glasses, three trays of desserts to be discarded, and two soiled trays were on the clean side counter. In addition, a cart of dirty dishes and four bowls of previously used peanuts was resting against/under the clean dry rack. The area was cleaned during the inspection.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; and (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
30
|
|
Site:
Galley-Signatures
|
|
Violation:
The lever for the right handwash station at the soiled dish drop-off was broken. The left handwash station was functional, and crew reported that only approximately 6 waiters service the area. The area was not open for service.
|
|
Recommendation:
Keep handwashing facilities clean and in good repair.
|
|
|
Item No.:
32
|
|
Site:
Galley-Warewash
|
|
Violation:
The pulper was out of service for approximately 5-6 days.
|
|
Recommendation:
Provide a receptacle or waste-handling container in each area of the vessel or premise where refuse is generated or commonly discarded or where recyclables are placed. Maintain pulper in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 5 Starboard Corridor Storage Room - FSD 05.05.47
|
|
Violation:
The room behind Fire Safety Door 05.05.47 was not properly constructed to standards for food equipment storage. The deck was not smooth and easily cleanable, and it was soiled with greater than a day's accumulation of debris. The deckhead was not smooth and easily cleanable; there were exposed pipes and wires similar to that of a technical space. Multiple pieces of clean and soiled food equipment were stored in this area. Crew immediately began removing the equipment to empty the room.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable. Install exposed utility service lines and pipes, including lines for fire detection and protection systems, so they do not obstruct or prevent cleaning. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Officer Mess
|
|
Violation:
A refrigerator containing soda was located on a carpeted deck.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
35
|
|
Site:
Galley-Dishwash
|
|
Violation:
The rack-type conveyor dishwasher was leaking water which pooled on the deck.
|
|
Recommendation:
Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
|
|
|
Item No.:
37
|
|
Site:
Buffet-Officer Mess
|
|
Violation:
Excessive condensation collected under the overshelf and the sneeze shield of the in-use bains-marie during service. One half-pan of the bains-marie was not covered, which allowed steam to escape. Dripping was not noted onto food, but was noted onto the counter. Crew immediately removed food to be discarded, and began cleaning the area.
|
|
Recommendation:
Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
37
|
|
Site:
Galley-Deck 5 Cold Galley Walk-In Room 247
|
|
Violation:
Water from condensation collected in a light fixture on the deckhead.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
37
|
|
Site:
Galley-Deck 5 Dishwash Starboard
|
|
Violation:
Excessive condensation accumulated on the deckhead above the clean end and over the middle of the rack-type conveyor dishwash machine. No dripping was noted. Crew immediately stopped the machine to clean the deckhead.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
38
|
|
Site:
Galley-Deck 5 Dishwash Storage Closet
|
|
Violation:
Four tables for decorations were stored in this area for clean food service items. Crew reported the tables are not used for food service or food displays. The tables had difficult-to-clean features such as Velcro and the coating was chipping.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
One fruit fly was located by the temperature control refrigerator at the crew mess beverage station.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Galley-Dishwash
|
|
Violation:
Two fruit flies were located at the rack-type conveyor dishwash machine.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Preparation Room-Warewash
|
|
Violation:
Two flies were observed at the soiled end of the potwash.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
40
|
|
Site:
Galley-Pool Grill
|
|
Violation:
Upon inspection of the pool grill during breakfast service, the door between the show galley/buffet area and the pantry was open due to a door malfunction. The inspector and crew discussed how the door needed to remain closed to prevent pest harborage because the Pool Grill was open to the outdoors. The inspector approached the Pool Grill during lunch service and the door was left open. Crew were observed going in and out of the pantry door without closing it behind them and the door did not automatically close. The inspector stood in front of the open door and took time while discussing the time control plan with the crew who were present in the morning, and no supervisors initiated the closing of the door until the inspector addressed the issue.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|