Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Victory I Cruise Line: Victory Cruise Lines Inspection Date: 07/03/2018 Inspection Score: 90
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 19
Site: Galley-Walk-in Refrigerator
Violation: This walk in freezer was over packed with boxes and packages of food products making it difficult to enter and walk through from the refrigerator entrance. Staff stated that this is an ongoing challenge as they do not have a walk in unit available in provisions area and face challenges with their itinerary. This was noted on the previous inspection.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; and (6) At least 150 millimeters (6 inches) above the deck on shelving racks. Protect food from contamination that may result from a physical, chemical, biological origin.
Item No.: 02
Site: Medical-Specimen Containers
Violation: The ship did not have a supply of viral specimen collection containers onboard. The last inspection noted the ship did not have bacterial agents. Staff stated the containers were ordered, but a purchase order was not presented during the inspection.
Recommendation: Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each), as well as a shipping container that meets the latest shipping requirements of the International Air Transport Association (IATA) and U.S. Department of Transportation for Biological Substances, Category B designated shipments (or higher). Ensure the vessel maintains the appropriate labels and markings required for shipping Biological Substances, Category B shipments. Ensure the vessel maintains appropriate refrigerant materials to keep clinical specimens cool. (see Annex 13.4 of the VSP 2011 Operations Manual.)
Item No.: 08
Site: Potable Water-Potable Water Hoses
Violation: Three, potable water hoses had the designated 'Potable Water Only' text faded. Staff re-painted the hoses during the inspection.
Recommendation: Label potable water hoses with the words ?POTABLE WATER ONLY? in letters at least 13 millimeters (0.5 inch) high at each connecting end.
Item No.: 08
Site: Potable Water-Potable Water Piping
Violation: The potable water line leaving the bunkering analyzer-chart recorder station was not labeled as potable water (blue/green/blue) on each side of the bulkhead. Additionally, the potable line leaving the bunkering analyzer-chart recorder station water was not striped every five meters (fifteen feet) at the potable water tank area.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Identify all refrigerant brine lines and nonpotable chilled water lines in all food areas, such as on ice machines, ice cream machines, etc., with either ISO 14726 (blue/white/blue) or by another uniquely identifiable method to prevent cross-connections.
Item No.: 06
Site: Potable Water-Potable Water Charts
Violation: No notations were present on the charts for unusual events. The inspector talked to staff about what information to include.
Recommendation: Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system. If electronic data loggers are used in lieu of chart recorders, record notations of any unusual events in the potable water system log.
Item No.: 08
Site: Potable Water-Backflow Prevention Device Log
Violation: The cross connection control program log, listed the medical facility shower backflow prevention device as 'one of twenty three' in cabins. No specific location or system component was listed.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 20
Site: Galley-Pastry/Bakery
Violation: There were approximately five slotted fasteners on the splash surface located just above the mixing bowl. These slotted fasteners were located on the rotating platform where the guard was installed. There was also a slotted fastener on the side of the rotating piece. These surfaces were clean to sight and touch during the inspection.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 20
Site: Galley-Pastry/Bakery
Violation: There were three slotted fasteners located in the food splash zone near the slide handle. These were clean to sight and touch.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 16
Site: Galley-Walk-in Refrigerator
Violation: There were two food containers on the shelf near the dairy area inside the walk in unit, which were open but not labeled for 7-day discard. One container contained herring in cream sauce and the other contained herring in mustard sauce. Both containers had the seal broken, and most of the product was used. These items were discarded during the inspection.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
Item No.: 19
Site: Dining Room-Waiter Station - Portside
Violation: There were two, metal hotel pans full of honeydew melon, which were placed on top of two columns of boxes inside the walk-in freezer unit (on the side accessed from the walk in refrigerator). These hotel trays were uncovered. Staff stated these were in a cooling process.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; and (6) At least 150 millimeters (6 inches) above the deck on shelving racks.
Item No.: 18
Site: Galley-Walk-in Refrigerator
Violation: This walk-in freezer was over packed with boxes and packages of food products making it difficult to enter and walk through from the refrigerator entrance. Staff stated that this is an ongoing challenge as they do not have a walk-in unit available in provisions area and face challenges with their itinerary. This was noted on the previous inspection.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
Item No.: 24
Site: Galley-Ice Cream Station
Violation: The chlorine concentration of bucket of sanitizing solution, located in this area, measured in excess of 200 ppm. Staff replaced the solution with a proper concentration.
Recommendation: Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm); (2) An iodine solution with a pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies the solution is effective AND a concentration between 12.5 mg/L (ppm) and 25 mg/L (ppm); (3) A quaternary ammonium compound solution with a concentration as specified in 40 CFR 180.940 Sanitizing Solutions AND as indicated by the manufacturer?s use directions included in the labeling. If another solution concentration or temperature of a chlorine, iodine, or quaternary ammonium compound is used, demonstrate to VSP that the solution achieves sanitization and the use of the solution is approved. If a chemical sanitizer other than a chlorine, iodine, or quaternary ammonium compound is used, ensure it is applied in accordance with the manufacturer?s use directions included in the labeling.
Item No.: 22
Site: Galley-Pastry/Bakery
Violation: A bucket of sanitizing solution at the entrance to this area was cloudy and soiled. Remediation began immediately.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 16
Site: Galley-Pastry/Bakery
Violation: There was a bowl of buttercream dated 26 June 2018, in the reach-in refrigeration unit in this area, which was in the temperature danger zone. Staff and the inspector measured multiple areas of the food product, which ranged in temperature from 45°F - 52°F. This bowl was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 16
Site: Galley-Pastry/Bakery
Violation: The temperature of a cheesecake stored in the undercounter refrigeration unit in this area ranged from 46°F - 47°F when measured with a tip sensitive thermometer by staff and the inspector. This item was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 21
Site: Galley-Soup/Grill Station
Violation: There was a long, absorbent string affixed to a hook to the left of the alto combination oven. Staff stated this was used to secure the combination oven units when the ship is in motion. The surface of this restraint was not smooth or easily cleanable. This restraining string was clean during the inspection.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Galley-Tilting Kettles
Violation: The electrical panels of both soup kettles had labels that were peeling making the surface uneven and difficult to clean. This area was clean to sight and touch during the inspection.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 28
Site: Dining Room-Portside
Violation: There were two large, tan colored storage bins stored on the top shelf of the metal shelving unit to the left of the undercounter glasswashing machine. These bins were full of approximately 10-stacks of white bowls, which were stored wet-nested. The bowls were removed for rewashing.
Recommendation: After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food.
Item No.: 28
Site: Galley-Clean Dish Storage
Violation: There was a plastic storage bin full of large, white bowls (approximately twenty), which were stored wet nested and in a manner prohibited drainage or air-drying. This bin was located on the bottom shelf to the left of the undercounter glasswashing machine. The bowls were removed for rewashing.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 22
Site: Galley-Warewashing Area
Violation: Two, blue-green plastic racks, used to wash dishes, were peeling and heavily coated with a brown, oily film. The inspector?s fingernail was able to remove this oily film.? Staff sent these items for disposal.
Recommendation: Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination and accumulation of excessive debris, and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
Item No.: 22
Site: Galley-Warewash Area
Violation: The undercounter glasswashing machine in this area had all but one nozzle blocked on the upper spray arm. Additionally, one spay nozzle was blocked on the bottom. Staff responded immediately to clear the debris.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 33
Site: Buffet-Deck
Violation: There was a hole in the deck between the food elevator and the handwashing sink in this area. A blue grate was placed to cover most of the opening, but a void space remained.
Recommendation: Ensure surfaces subject to routine splashes, spillage, or other soiling during normal use have easily cleanable features. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 28
Site: Other-Electrical Closet
Violation: There was a small, blue and white cooler stored wet and soiled inside the electrical closet behind the Seascape Bar. Staff stated this cooler was used to transport ice to the Seascape Bar. This cooler was removed for rewash. There was also a large, water cooler with a spigot that was stored wet and soiled inside the same closet. Staff stated this cooler was filled with beverages for guests as they board the ship. This cooler was also removed and rewashed.
Recommendation: If used with potentially hazardous food, ensure equipment, food-contact surfaces, and utensils used on a continuing basis are washed, rinsed, and sanitized at least every 4 hours. Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 26
Site: Dining Room-Portside
Violation: There was a small, blue and white cooler stored wet and soiled in the electrical closet behind the Seascape Bar. Staff stated that this cooler is used to transport ice to the Seascape Bar. This was removed to be rewashed. There was also a large, water cooler with a spigot stored wet and soiled in the same closet. Staff stated this cooler is filled with beverages for guests as they board the ship. This cooler was also removed and rewashed.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Dining Room-Waiter Station - Portside
Violation: There was an accumulation of food and soiled dishes stored on a waiter tray stored on a stand in a carpeted area. This accumulation was reportedly from the breakfast service, which had ended approximately forty-five minutes earlier. These items were not taken to the galley for proper disposal and storage.
Recommendation: Ensure bulkheads and deckheads have smooth, hard finishes and light colored surfaces. Exception: bars may have decorative surfaces provided that they are easily cleanable. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 19
Site: Buffet-Cliff Rock Bar and Grill
Violation: The sneeze shield located at the most aft end of the buffet station was insufficient. No food was being served at the time of the inspection.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 33
Site: Provisions-Liquor Storage Room
Violation: The deckhead was not enclosed in this area. Piping and other electrical conduit was strewn above stored bottles of beer, wine, liquor, and other beverage containers.
Recommendation: Install exposed utility service lines and pipes, including lines for fire detection and protection systems, so they do not obstruct or prevent cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 28
Site: Dining Room-Galley Entrance- Starboard Side
Violation: There were unprotected stacks of previously cleaned glassware in racks stored outside the galley, in the access hallway to the dining area. There was also a previously used opened bottle of water stored inside the rack with the clean dishes.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck unless in packages on pallets, skids, or racks, which may be 127 millimeters (5 inches).
Item No.: 26
Site: Dining Room-Starboard
Violation: There were three stacks of previously cleaned plates, stored on a waiter tray inside the dining area, uncovered and upright. These plates were used to re set the dining room tables for the next service period. Four of these plates had food debris on stuck to the food-contact surface. These items were removed for rewashed.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 22
Site: Dining Room-Portside Waiter Station
Violation: There was an accumulation of food and soiled dishes stored on a waiter tray on a stand in a carpeted area. This accumulation was reportedly from the breakfast service, approximately forty-five minutes prior to the inspectors boarding the ship.
Recommendation: Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program