Cruise Ship: Stad Amsterdam Cruise Line: Rederij Clipper Stad Amsterdam Inspection Date: 04/24/2017 Inspection Score: 88
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 40
Site: Integrated Pest Management-
Violation: Two of the ventilation units were observed having several live mosquitoes resting in the standing water near the filters.
Recommendation: In nonfood areas, give reasonable care to conduct inspections for the presence of insects, rodents, and other pests.
Item No.: 27
Site: Bar-Indoor
Violation: The counter under the coffee machine and milk refrigerator was soiled with greater than a day's accumulation of debris underneath.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 39
Site: Galley-Potwash
Violation: One fly was noted in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Galley-
Violation: The deck under the combination oven was excessively soiled with greater than one day's accumulation of debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 17
Site: Galley-
Violation: A pan of red beet salad located in the undercounter refrigerator had a discard date of 27 April. The cooling logs listed a red beet salad prepared on 18 April. Crew indicated the red beet salad currently in the refrigerator was from a different batch prepared after 18 April, but there were no cooling logs for that batch.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 16
Site: Galley-Walk-In Refrigerator
Violation: An open container of yogurt was measured at 11°C by the inspector. A sealed container of yogurt was measured at 12°C by both the inspector and a crew member. An open container of mozzarella cheese measured at 13°C by the inspector and 14°C by the crew. Crew reported the cheese was used for breakfast earlier that morning but was only out of the refrigerator for approximately 15 minutes. All three items were located near the door to the walk-in refrigerator. The inspector and crew discussed keeping non-potentially hazardous foods (PHF) closer to the door, and relocating PHF food to a different location in the refrigerator. Additionally, the internal thermometer measured 10°C in the walk in refrigerator. Crew and the inspector also discussed lowering the temperature in the refrigerator.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 20
Site: Galley-Walk-In Refrigerator
Violation: The internal thermometer of the only walk-in refrigerator on the vessel noted above measured 10°C. Multiple potentially hazardous food items were measured in the danger zone.
Recommendation: Ensure equipment for cooling and heating food, and holding cold and hot food, is sufficient in number and capacity to maintain potentially hazardous food temperatures. Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines;
Item No.: 17
Site: Galley-Walk-In Refrigerator
Violation: A pan of salmon salad had a discard date of 28 April. Crew explained that salmon was cooked and cooled. After that, the salmon salad would be prepared and cooled. There was no record of the cooling process for the salmon or the salmon salad on the cooling log.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 22
Site: Galley-Potwash Machine
Violation: The inspector was unable to obtain a measurement of 160°F or higher at the plate surface during final rise sanitization after four attempts. Upon further inspection of the hood type machine, two wash nozzles were partially blocked. One end cap of the wash manifold was not flush with the machine, was missing a screw to hold it on, and had debris trapped in this area. When listening to the machine, the wash cycle could be heard but there was no distinct pause for draining followed by the final rinse that could be heard. No other mechanical warewash machines were located in the main galley. The only other warewash machines onboard were two glasswash machines, each in a bar area. The potwash machine was in use at the time of inspection. Technical staff were requested for assistance but were unable to be fix the machine at that time. The inspector took a fifth reading of the plate surface of the final rinse, which was 155°F. Crew began using a large compartment sink to sanitize with 171°F for 30 seconds.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 24
Site: Galley-Potwash Machine
Violation: The inspector was unable to obtain a measurement of 160°F or higher at the plate surface during final rise sanitization after a total of 5 attempts. The only other warewash machines onboard were 2 glasswash machines, each in a bar area. Crew began using a large compartment sink to sanitize with 171°F for 30 seconds.
Recommendation: Sanitize food-contact surfaces of equipment and utensils. In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 29
Site: Bar-Outdoor
Violation: The handwash sink measured a maximum temperature of 80°F. Crew reported there was no boiler for this sink and it would be fixed in Europe at the end of May. The area was not in service at the time; however, it was in service later during the inspection.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 33
Site: Bar-Outdoor
Violation: The cleaning locker had a large opening in the bulkhead around a pipe, leading to the void space behind the area. This created a difficult to clean area.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 19
Site: Bar-Indoor
Violation: Bowls containing salami, cheese, nuts, pretzels, peanut chocolate candy, and apples were on display as a temporary buffet at the bar for guest consumption. Guests could stand within 6 inches (150 mm) of the food. The food was not protected with a sneeze guard or by any other means. The food was immediately removed.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches). Protect food from contamination that may result from a physical, chemical, biological origin.
Item No.: 21
Site: Bar-Indoor
Violation: The coffee machine and milk refrigerator were not easily moveable, which made it difficult to clean behind the machines. There was not adequate space around the sides of the machine to be able to clean behind. The milk dispenser was raised approximately 1cm which created a difficult to clean area, and the counter was soiled with greater than a day's accumulation of debris underneath.
Recommendation: Ensure equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead. Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
Item No.: 30
Site: Housekeeping-Passenger Toilet (Portside) Reception Area
Violation: The portside passenger toilet in the reception area did not have paper towels for handwashing. The towels were added during the inspection.
Recommendation: Ensure each handwashing facility has a supply of hand-cleansing soap or detergent and a supply of single-service paper towels available.
Item No.: 40
Site: Integrated Pest Management-Passenger Toilet (Portside) Deck Area
Violation: The portside deck toilet room had an excessive amount of flying insects inside the toilet area. Approximately 40 insects were present. The room had a slatted vent next to the door which was open to the outside; however, no screen or other protection from pest entry was present.
Recommendation: Protect entry points where pests may enter the food areas. In nonfood areas, give reasonable care to conduct inspections for the presence of insects, rodents, and other pests.
Item No.: 23
Site: Galley-Potwash Machine
Violation: The data plate of the machine indicated a minimum wash temperature of 55°C, which is lower than the 66°C requirement.
Recommendation: Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (1) 74°C (165°F) for a stationary-rack, single-temperature machine; (2) 66°C (150°F) for a stationary-rack, dual-temperature machine; (3) 71°C (160°F) for a single-tank, conveyor, dual-temperature machine; (4) 66°C (150°F) for a multi-tank, conveyor, multi-temperature machine.
Item No.: 08
Site: Potable Water-Bunkering Records
Violation: No start and stop times were noted on the bunkering logs for multiple days. It was unclear how long bunkering occurred during each time.
Recommendation: Maintain accurate records of production and bunkering monitoring aboard for 12 months and ensure these records are available for review during inspections.
Item No.: 08
Site: Potable Water-Production Records
Violation: During the month of April, production occurred for many days for up to 10 hours at a time. Records did not indicate if 2 ppm chlorine was reached within 30 minutes of starting production, and there were no records of maintaining at least 2 ppm chlorine every 4 hours.
Recommendation: Adjust the free halogen residual level to at least 2.0 mg/L (ppm) within 30 minutes of the start of the bunkering and production processes. After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least once every 4 hours during the production of potable water.
Item No.: 07
Site: Potable Water-Skin Tank Variance
Violation: The ship has 4 potable water tanks which share walls and tank bottoms with the hull of the vessel. A variance request was submitted to VSP in December 2014 for procedures using salinometer readings. VSP returned the variance request to the ship with comments for alarm installation and salinometer readings at least every 4 hours each day. No variance documentation was available onboard, but e-mails within the company stated they returned the variance to VSP in early 2016. This updated variance and communication with VSP was not available.
Recommendation: Ensure potable water tanks do not share a common wall with the hull of the vessel or with tanks or piping containing nonpotable water or other liquids.
Item No.: 08
Site: Potable Water-Bunker Station
Violation: The potable water hose storage shelf was not self draining. Additionally, there were different size hoses used for bunkering. The small marina hose used for bunkering was open and not protected on each end.
Recommendation: Ensure the hose connections are unique and fit only the potable water hoses. Mount potable water hose lockers at least 460 millimeters (18 inches) above the deck and ensure they are self draining. Ensure potable water hoses are rolled tight with the ends capped, on reels, or on racks, or with ends coupled together and stowed in potable water hose lockers.
Item No.: 08
Site: Potable Water-Shoreside Connection
Violation: Following the April 2015 inspection, a reduced pressure assembly was installed at the international shore connection. There was no documentation to demonstrate the device had been tested upon installation or annually after the initial installation. Crew also reported the device was not tested upon installation or annually. In addition, the list of backflow preventers (dated November 2016) indicated a continuous pressure device at this location, which was different from what was actually installed.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 43
Site: Ventilation-
Violation: Two of the units were observed having several live mosquitoes resting in the standing water near the filters. Additionally the condensation collection pans for all units could not be viewed for inspection. This was written on the last inspection.
Recommendation: Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical. Keep air handling units clean.
Item No.: 44
Site: Potable Water-
Violation: The person(s) responsible for maintaining potable water records and systems were not following the VSP manual. For example: (1) bunkering records were not properly documented; (2) production records were not properly documented and it was unclear if monitored chlorine values were at least 2 ppm every four hours; (3) the international shore connection had not been pressure tested upon installation or annually; and (4) the ship did not have a copy of the pending skin tank variance nor communication with VSP, which they indicated was sent in early 2016.
Recommendation: Procedures, systems, equipment, technology, processes, or activities that are not identified in the scope of this manual must not be tested or introduced operationally onboard any vessel until the concept is submitted in writing to the VSP Chief for review. If the review determines the concept is within the scope of the VSP Operations Manual, written procedures, control measures, or a complete variance submission may be required. Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.