Item No.:
*
|
|
Site:
Potable Water-Far Point Record Review
|
|
Violation:
Multiple far point records were missing information as to time zone changes or vessel being out of service due to maintenance, etc. Missing information made it unclear why the charts were out of range and there was no calibration.
|
|
Recommendation:
Recommend turning the pen/chart recorders off when the vessel is not in operation and there are no passengers or crew.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Record Review
|
|
Violation:
On 08 April 2017, the far point chart record was above 5ppm Chlorine from 1100 to 0700 the next day. There were no manual readings noted nor calibration or response to the elevated reading.
|
|
Recommendation:
Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Record Review
|
|
Violation:
Starting 15 May 2017 to 16 May 2017 the far point chart did not record from 1520 to 0600. Manual notes on the chart stated that it was 'found with no power to the unit at 0300' on 16 May. Staff stated that there were a couple of times where the recorder was unplugged and the backup battery failed. There was no other documentation on the chart for repairs or manual readings . It was not noted that an alarm notified staff of the issue.
|
|
Recommendation:
In the event of equipment failure, measure the free residual halogen by a manual test kit at the halogen analyzer at least every 4 hours.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Record Review
|
|
Violation:
On 14 May 2017 the chart recorder for far point measured above 5ppm chlorine from1230 to 0045. A note on the chart read 'Too much chloride injected during bunkering of water in Juneau'. There were no manual readings noted. It was unclear if an alarm alerted staff to respond to the issue because there was no documentation and the issue persisted for over 12 hours.
|
|
Recommendation:
Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Record Review
|
|
Violation:
Multiple far point records from 30 April to 2 May 2017 showed various issues including; chlorine above 5 ppm, no recordings at all or wildly unstable readings. Staff explained that during this time, the vessel was in the yard for maintenance and there were no crew or passengers on board using the water system. No documentation was noted on the charts or elsewhere explaining this time frame and the abnormal events recorded. It was unclear why the staff chose to continue recording the far point and to continue to dose chlorine but not maintain the probe or other equipment.
|
|
Recommendation:
Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel. Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system. In the event of equipment failure, measure the free residual halogen by a manual test kit at the halogen analyzer at least every 4 hours.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Record Review
|
|
Violation:
On 5 November 2016, the far point chart recorder was above 5 ppm from 0800 to 1900. There were no manual readings noted for this timeframe. It was not clear whether an alarm alerted staff to the issue or there was any calibration or repairs made to the recorder.
|
|
Recommendation:
Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Record Review
|
|
Violation:
On 8 November 2016, the far point chart recorder overlapped from approximately 0715 to 0845. A hand written note on the chart stated 'out of calibration' for an occurrence of high chlorine (above 5 ppm from 2250 to 2325) and also noted that the overlapping of the chart was due to a loss of calibration or high chlorine. This was unclear. It was also not noted that the analyzer was calibrated nor whether an alarm notified staff of the issue.
|
|
Recommendation:
Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Record Review
|
|
Violation:
The far point chart recorder overlapped from 0800 to1415 from 2 November 2016 to 3 November 2016. There were no hand written notes to explain the issue.
|
|
Recommendation:
Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Spa High and Low Alarms
|
|
Violation:
No high or low level alarms for pH and halogen were installed for the whirlpool spas. This was written on the previous three inspection reports.
|
|
Recommendation:
Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children?s pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Spa High and Low Alarms
|
|
Violation:
There was no documentation that the single, blockable suction fitting cover in each whirlpool spa was certified as an antientrapment cover. In addition there was no secondary antientrapment protection installed on the suction line, such as a safety vacuum release system or automatic pump shut off. These whirlpool spas were household grade and not commercial grade.
|
|
Recommendation:
For RWFs with gravity drainage and a single blockable drain or multiple drains less than 3 feet apart, provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a gravity drainage system.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Spa High and Low Alarms
|
|
Violation:
The values recorded by the electronic data logger for the port and starboard whirlpool spas were not stored in a secure database nor were they tamper-proof. Staff stated that they were aware of this but do not tamper with the records. This was written on the last three inspection reports.
|
|
Recommendation:
Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children?s pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
|
|
|
Item No.:
44
|
|
Site:
Recreational Water Facilities-Recreational Water Facilities
|
|
Violation:
Although multiple improvements have been made for the recreational water facilities, there were still some practices which were not in accordance with the 2011 VSP Operations Manual, including high and low level alarms, antientrapment protection records and electronic data logger security. Staff stated that they were aware and planned to procure equipment to meet these requirements.
|
|
Recommendation:
Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP?during inspections and on request ? knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|
|
Item No.:
44
|
|
Site:
Potable Water-Records and Maintenance
|
|
Violation:
The potable water system was not being maintained in accordance with the 2011 VSP Operations Manual. There were occasions of no far point recordings due to power loss, high ppm, technical failures and overlapping chart recorders. During these occasions, there was no manual documentation explaining any action taken or manual readings.
|
|
Recommendation:
Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|
|
Item No.:
39
|
|
Site:
Galley-Pastry Preparation
|
|
Violation:
One fruit fly was observed in this area.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
18
|
|
Site:
Galley-Pastry Preparation Refrigeration
|
|
Violation:
Raw shell eggs were stored above ready-to-eat mango puree and pears. One container of egg yolk was stored above containers labeled 'caramel layer.' The raw shell eggs were relocated.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
28
|
|
Site:
Galley-Pastry Preparation - Dish Rack
|
|
Violation:
Several hotel pans were stored wet nested. These were immediately sent to the dish area for cleaning.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
31
|
|
Site:
Galley-Dish Area
|
|
Violation:
A container of dish detergent did not have a label. This was immediately corrected.
|
|
Recommendation:
Ensure working containers used for storing poisonous or toxic materials such as cleaners and sanitizers taken from bulk supplies are clearly and individually identified with the common name of the material.
|
|
|
Item No.:
31
|
|
Site:
Dining Room-Wine Bar
|
|
Violation:
A crate of cleaning material was found under the sink. The cabinet was not labeled 'CLEANING MATERIALS ONLY.' The crate was moved to the cleaning locker located in the galley.
|
|
Recommendation:
Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
18
|
|
Site:
Bar-Explorer Lounge Undercounter Refrigerator
|
|
Violation:
Eggs were stored above bottles of beverages. These were relocated.
|
|
Recommendation:
Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry?except when combined as ingredients?during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP did not contain procedures for returning the vessel to normal operating conditions after an outbreak. There were no threshold levels noted for returning to baseline.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Duties and responsibilities of each department and their staff for all the passenger and crew public areas; (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (5) Procedures for returning the vessel to normal operating conditions after an outbreak; (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
|
|