|
|
|
Item No.:
16
|
|
Site:
Dining Room-Menu
|
|
Violation:
The cold smoked salmon on the menu was not linked to the consumer advisory.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
21
|
|
Site:
Dining Room-Waiter Stations
|
|
Violation:
The waiter stations at the port and starboard end of the forward buffet line, which were constructed out of a sealed wood, were not properly coved around the inside perimeter.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Waiter Stations
|
|
Violation:
The light intensity at the port and starboard side waiter stations could not be raised to 220 lux for cleaning. Also, the light intensity behind and around the counter mounted espresso machine and refrigerator at the port beverage pantry was less than 110 lux. These areas were noted on the previous inspection report.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
08
|
|
Site:
Dining Room-Ice Machine
|
|
Violation:
The newly installed ice machine had only a non-return valve installed and no internal air gap.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment.
|
|
|
Item No.:
16
|
|
Site:
Galley-Time Control Plan
|
|
Violation:
During the inspection, staff stated hot food went on time control on the bains marie at approximately 11:45 AM even though the posted time control plan for the area stated lunch service on a port day was from 12:30 to 14:00.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
08
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The backflow prevention devices on the potable water lines for the combination oven next to the flat grill were painted over, which blocked the atmospheric vents.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
22
|
|
Site:
Galley-Pot Wash
|
|
Violation:
An excessive amount of soiled pots and pans were accumulated at the soiled drop-off area of the pot wash. A mobile trolley was used to help with soiled storage but it was placed less than less than 1 meter (2 feet) from the blast chiller. The blast chiller was in use during the inspection which meant the food items passed closed by the soiled pots and pans on the way into the blast chiller.
|
|
Recommendation:
Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
|
|
|
Item No.:
29
|
|
Site:
Galley-Pastry
|
|
Violation:
A mobile trolley was parked in front of the handwash sink.
|
|
Recommendation:
Ensure handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
25
|
|
Site:
Galley-Pastry
|
|
Violation:
The sanitizing cloth was hanging over the side of the sanitizing bucket.
|
|
Recommendation:
Restrict wiping cloths to the following: (1) Cloths used for wiping food spills are used for no other purpose; (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment; (3) Dry or wet cloths used with raw animal foods are kept separate from cloths used for other purposes. Wet cloths used with raw animal foods must be kept in a separate sanitizing solution; (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
|
|
|
Item No.:
17
|
|
Site:
Galley-Pastry Cooling Logs
|
|
Violation:
The cooling log for vanilla sauce prepared on 23 September showed the cooling process started 06:21 but the first temperature check was not taken until 08:32.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41°F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewash
|
|
Violation:
Several plate covers were leaning on one another on a rack that went through the rack-type dishwash machine.
|
|
Recommendation:
Ensure soiled items to be cleaned in a warewashing machine are loaded into racks, trays, or baskets or onto conveyors in a position that (1) exposes the items to the unobstructed spray from all cycles; (2) allows the items to drain.
|
|
|
Item No.:
36
|
|
Site:
Galley-Palm Garden Buffet
|
|
Violation:
The light intensity behind and around the ice machine was less than 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
20
|
|
Site:
Galley-Palm Garden Buffet
|
|
Violation:
The left side of the flat grill cooking surface had a large seam at the juncture of the side of the grill
|
|
Recommendation:
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
26
|
|
Site:
Galley-Palm Garden Buffet
|
|
Violation:
The seam on the left juncture of the flat grill cooking surface was soiled with an accumulation of old food debris.
|
|
Recommendation:
Ensure food-contact surfaces of cooking equipment and pans are kept free of encrusted grease deposits and other soil accumulations.
|
|
|
Item No.:
27
|
|
Site:
Galley-Palm Garden Buffet
|
|
Violation:
The grease chute on the flat grill and the grease collection pan was soiled with food residue. The outlet was open for breakfast in the morning but had been closed for several hours by the time the inspection team arrived to the area.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
38
|
|
Site:
Galley-Warewash
|
|
Violation:
A squeegee was stored against the clean storage rack. The area was not in operation.
|
|
Recommendation:
Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles.
|
|
|
Item No.:
38
|
|
Site:
Galley-Palm Garden Buffet
|
|
Violation:
The two cleaning material lockers in the galley were not labeled 'CLEANING MATERIALS ONLY.'
|
|
Recommendation:
Label the locker "CLEANING MATERIALS ONLY."
|
|
|
Item No.:
28
|
|
Site:
Galley-Palm Garden Buffet Warewash
|
|
Violation:
Four wine cooler buckets were stored wet and stacked on the clean storage rack.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
08
|
|
Site:
Galley-Ice Machine
|
|
Violation:
The ice machine only had a nonreturn valve installed on the potable water supply line and did not have an internal air gap.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment.
|
|
|
Item No.:
20
|
|
Site:
Galley-Upper Escalator Corridor
|
|
Violation:
The bread slicer machine had three slotted fasteners on the food contact surface.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
21
|
|
Site:
Galley-Upper Escalator Corridor
|
|
Violation:
The plastic lid at the exit of the bread slicer machine was cracked, making it difficult to clean. Also, the bread slicer machine was installed with less than a 6-inch (150 mm) clearance with the deck.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure deck-mounted equipment that is not easily movable is sealed to the deck or elevated on legs that provide at least a 150 mm (6-inch) clearance between the deck and the equipment.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Bunkering/Production Records
|
|
Violation:
Since 15 September, no calibration was recorded on the chart record at the beginning of bunkering or production on seven different occasions. Also, the production chart record for 20 September was not dated.
|
|
Recommendation:
Calibrate at the beginning of bunkering or production when halogen and pH analyzer-chart recorders are used in lieu of manual tests and logs. Ensure the calibration is recorded on the chart. Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Testable Devices
|
|
Violation:
The six reduced pressure backflow assemblies located in the engine room spaces only had one pressure value recorded; however, the testing procedures for the devices listed four separate tests. Also, the reduced pressure backflow assemblies installed on both international shore connections and both sprinkler connections were tested on 6 May but no values were recorded.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Production
|
|
Violation:
The reduced pressure backflow assembly on the distillate water line after the evaporators was installed before the line divided to the technical water tank and fresh water production. This arrangement could allow for technical water from the technical water tank to backflow into the fresh water production line.
|
|
Recommendation:
Ensure the potable water distribution system is maintained free of cross-connections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Production/Bunkering Injection Points
|
|
Violation:
The distance between the chlorine and pH injection points and sample point for the analyzer on the combine production and bunkering line was less than 10 feet (3 meters). This was noted on the previous inspection report.
|
|
Recommendation:
Obtain water samples for halogen and pH testing from a sample cock and/or a halogen analyzer probe located on the bunker or production water line at least 3 meters (10 feet) after the halogen injection point and before the storage tank.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Evaporators
|
|
Violation:
The high salinity overboard discharge line for both evaporators did not have an air gap or reduced pressure backflow assembly installed. This was noted on the previous inspection report.
|
|
Recommendation:
Ensure the potable water distribution system is maintained free of cross-connections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Evaporators
|
|
Violation:
The high salinity overboard discharge line for both evaporators did not have an air gap or reduced pressure backflow assembly installed. This was noted on the previous inspection report.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (24) high saline discharge line from evaporators (install an air gap or a reduced pressure assembly).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenance
|
|
Violation:
Potable water tank 2.1 Central was inspected and painted on 5 May but no information was recorded on if the paint manufacturer's recommendations for drying and curing were met. The documentation for cleaning and sanitizing of this tank only stated 200 ppm chlorine was used and no contact time was recorded. Potable water tank 2.0 Port was inspected and painted on 19 April but no information was recorded on if the paint manufacturer's recommendations for drying and curing were met. The documentation for cleaning and sanitizing of this tank only stated 200 ppm chlorine was used and no contact time was recorded. Potable water tank 2.0 Starboard Central was inspected 7 April but the documentation for cleaning and sanitizing of this tank only stated 200 ppm chlorine was used and no contact time was recorded. The final chlorine residual value of all three tanks before they were placed back into service was not documented, which was also noted on the previous inspection report.
|
|
Recommendation:
Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers' recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers' recommendations for application, drying, and curing; and (3) written documentation that the manufacturers' recommendations have been followed for application, drying, and curing. Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service. Document the free halogen residual level.
|
|
|
Item No.:
05
|
|
Site:
Potable Water-Distribution Far Point
|
|
Violation:
The inspector's measured chlorine values at the far point were 2.31 ppm and 2.20 ppm, and the crew member's measured chlorine values were 1.78 ppm and 1.71 ppm. The analyzer was reading a chlorine value of 1.73 ppm during these tests. However, the calibration of the crew member's test kit could not be verified. Staff had calibration reference standards that were not expired but the values of the standards were measured in 'nm' and 'mAbs.' Staff could not explain how these values were related to chlorine, which is measured in ppm (mg/L).
|
|
Recommendation:
Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Test Kit Secondary Standards
|
|
Violation:
The calibration of the crew member's test kit could not be verified. Staff had calibration reference standards that were not expired but the values of the standards were measured in 'nm' and 'mAbs.' Staff could not explain how these values were related to chlorine, which is measured in ppm (mg/L).
|
|
Recommendation:
Ensure the halogen test kit used to calibrate the halogen analyzer is accurate to within 0.2 mg/L (ppm) for halogen and graduated in increments no greater than 0.2 mg/L (ppm) in the range of free residual halogen normally maintained in the potable water system. Ensure all reagents used with the test kit are not past their expiration dates. Where available, maintain appropriate secondary standards onboard for electronic test kits to verify test kit operation.
|
|
|
Item No.:
02
|
|
Site:
Medical-Specimen Collection Tubes
|
|
Violation:
The ship did not have any specimen collection tubes for bacteria.
|
|
Recommendation:
Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each), as well as a shipping container that meets the latest shipping requirements of the International Air Transport Association (IATA) and U.S. Department of Transportation for Biological Substances, Category B designated shipments (or higher). Ensure the vessel maintains the appropriate labels and markings required for shipping Biological Substances, Category B shipments. Ensure the vessel maintains appropriate refrigerant materials to keep clinical specimens cool. (see Annex 13.4 of the VSP 2011 Operations Manual.)
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Port Side Waiter Stations
|
|
Violation:
The light fixtures above the center waiter stations on the port side of the dining room were burnt out, which meant the light intensity could not be raised to a minimum of 220 lux for cleaning operations.
|
|
Recommendation:
In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
36
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The light intensity behind both deck-mounted combination ovens was less than 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
13
|
|
Site:
Food Service General-Employee Knowledge
|
|
Violation:
Lack of managerial control and employee knowledge in the galley lead to four critical violations. First, the accumulation of soiled pots and pans was not being managed in a sanitary manner which caused a trolley stacked with soiled pots and pans to be stored within 2 feet of the blast chiller during operation. Second, staff was not following the posted time control for galley by placing food on time control in the bains marie at 11:45 for lunch when the time control plan stated the lunch service period on port days was from 12:30 to 14:00. Third, during a conversation about cooling, staff stated that if a product does not reach 21C within two hours of cooling they just keep the product in the blast chiller until it reaches temperature. Staff stated it was only at this point the product they would slack the product or place it into shallow pans. Fourth, staff in charge of taking temperatures of the rack-type dishwash machine were not aware of the importance of isolating and measuring the final rinse spray.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases that are transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of potentially hazardous food, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control pints in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual.
|
|