Cruise Ship: Arcadia Cruise Line: P&O Cruises Inspection Date: 09/20/2017 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 28
Site: Pantry-Medical
Violation: In the medical pantry, five previously cleaned glasses were found stored wet and stacked. The glasses were removed and cleaned during the inspection.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 40
Site: Integrated Pest Management-Forward Rat Guards
Violation: Three forward mooring lines had ineffective rat guards. The placement created a gap on each of the lines, which gave pests an avenue to pass through to the ship. Staff added and staggered the rat guards to eliminate the gap/entry point.
Recommendation: Protect entry points where pests may enter the food areas.
Item No.: *
Site: Potable Water-Production Log
Violation: On 9 September, for thirty minutes, the pH reading on the chart recorder read approximately 7.9 to 8.0. These values were verified in the log. Staff stated that this happens randomly when some of the water tanks are topped off with water that has a higher concentration of halogen than the tank. This was an infrequent occurrence; however, the inspector talked to the staff about making notes on the chart recorder to verify the reason for these events. In the past inspection report, this occurrence was noted however the pH levels were out of calibration for extended periods of time for multiple days and the log entries did not match the chart recorder readings. This was not the case for this situation.
Recommendation: Ensure that Halogen and pH deviations are noted and explained on the chart recorder.
Item No.: 33
Site: Galley-Deck 2 Hot Galley
Violation: Water was dripping from the deckhead exhaust vent in front of the blast chiller. No food was impacted.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 28
Site: Galley-Deck 2 Pot Wash
Violation: Three soiled deck mixer bowls were stored on a deck stand directly next to another deck stand that had two cleaned and inverted deck mixer bowls. These deck stands were located in the clean storage area. The soiled drop-off area was overwhelmed with soiled pots and pans, which caused the soiled items to flow over to the clean storage area.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 22
Site: Galley-Deck 2 Pot Wash
Violation: Three soiled deck mixer bowls were stored on a deck stand directly next to another deck stand that had two cleaned and inverted deck mixer bowls. These deck stands were located in the clean storage area. The soiled drop-off area was overwhelmed with soiled pots and pans, which caused the soiled items to flow over to the clean storage area.
Recommendation: Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
Item No.: 37
Site: Galley-Deck 2 Pot Wash
Violation: Water was dripping from the exhaust vent above the third compartment of the three-compartment sink into the water of that compartment. This happened while the three-compartment sink was in active use. In addition, condensation was accumulating on deckhead around the exhaust hood canopy above the pot wash machine. When the pot wash machine was running, a significant amount of the steam being release was escaping the exhaust hood canopy. Staff later determined the exhaust system was still operating in an energy-saving mode that reduced the effectiveness of the exhaust vents.
Recommendation: Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 33
Site: Galley-Deck 2 Pot Wash
Violation: The exhaust vent above the third compartment of the three-compartment sink was heavily soiled with an accumulation of dust.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 34
Site: Galley-Deck 2 Pot Wash
Violation: Water was leaking from the supply line to submerged inlets of the pulper machine.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 34
Site: Galley-Deck 2 Hot Galley
Violation: Water was dripping from the filling faucet between the two far right soup kettles.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 28
Site: Galley-Deck 2 Walk-in Refrigerator 23
Violation: Three previously cleaned long serving dishes were stored upright on the top shelf of the storage rack.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air-drying, and covered or inverted.
Item No.: 19
Site: Galley-Deck 2 Pastry
Violation: A tray of mango parfaits was stored uncovered on the top shelf of the storage rack in the walk-in freezer.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 20
Site: Galley-Deck 2 Room Service
Violation: The coating on the top interior surface of the countertop convection oven was peeling.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
Item No.: 21
Site: Galley-Deck 2 Room Service
Violation: The countertop convection oven was not installed with a minimum 100 mm (4-inch) clearance between the bottom of the unit and the countertop.
Recommendation: Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
Item No.: 38
Site: Galley-Deck 2 Room Service
Violation: The cleaning locker across from room service was not labeled 'CLEANING MATERIALS ONLY.'
Recommendation: Label the locker "CLEANING MATERIALS ONLY."
Item No.: 37
Site: Galley-Deck 2 Warewash
Violation: Condensation had accumulated on the deckhead around the exhaust vents inside the canopy hood. Condensation was also accumulating around the perimeter of the canopy hood and dripping to the deck. Staff later determined the exhaust system was still operating in an energy-saving mode that reduced the effectiveness of the exhaust vents.
Recommendation: Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 24
Site: Galley-Deck 2 Warewash
Violation: The final rinse manifold temperature of the conveyor dishwash machine was measured above 200F during operation. Steam was being produced from the final rinse spray nozzles, but the surface temperature was still measured above 160F.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 22
Site: Galley-Deck 3 Warewash
Violation: The rack-type glass wash machine had been out-of-order since the day prior to the inspection.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 28
Site: Galley-Deck 3 Beverage Station
Violation: Two stacks of previously cleaned plastic plate covers stored in a plate trolley were stacked and stored wet.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air-drying, and covered or inverted.
Item No.: 30
Site: Galley-Deck 3 Toilet Room
Violation: The toilet room door did not close properly.
Recommendation: Ensure toilet rooms are completely enclosed and have tight-fitting, self-closing doors which are kept closed except during cleaning or maintenance.
Item No.: 08
Site: Galley-Deck 3 Hot Galley
Violation: Water was leaking from the atmospheric vents on the backflow prevention device installed on the potable water supply line to the middle combination oven.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 22
Site: Galley-Deck 3 Pot Wash
Violation: The mechanical pot wash machine had been out-of-order since 18 September.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 16
Site: Preparation Room-Walk-in Refrigerator
Violation: A large, 8-inch hot pan of cut iceberg lettuce was stored in the walk-in refrigerator at a temperature of 52°F (11°C) when measured by the inspector at 11:30 AM. According to the cooling log, the iceberg lettuce reached 39°F (3.9°C) at 3:55 AM the morning of the inspection. The lettuce was immediately discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 38
Site: Preparation Room-Fish
Violation: A sanitizing bucket stored in the cleaning materials locker was not inverted.
Recommendation: Ensure wash, rinse, and sanitize buckets or other containers stored with maintenance tools are inverted and nested.
Item No.: 38
Site: Buffet-Forward Crew Hot Line
Violation: A mobile hot holding cabinet was stored at the end of the service line but was no longer used in the operation.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 37
Site: Buffet-Forward Crew Hot Line
Violation: An excessive amount of steam was escaping from the bain marie, which was operating on time control, and accumulating on the sneeze shield. Although no condensation was observed dripping from the sneeze shield into the food below, crewmembers had to bend under the sneeze shield to see what food products were out on the hot line. This negated the effectiveness of the sneeze shield.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 19
Site: Buffet-Forward Crew Hot Line
Violation: An excessive amount of steam was escaping from the bain marie, which was operating on time control, and accumulating on the sneeze shield. Although no condensation was observed dripping from the sneeze shield into the food below, crewmembers had to bend under the sneeze shield to see what food products were out on the hot line. This negated the effectiveness of the sneeze shield.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 24
Site: Galley-Pot Wash
Violation: The water temperature in the sanitizing compartment of the three-compartment sink was measured at 167° F during operation. The third compartment was using hot water for sanitizing. It was later determined that the heater for the third compartment was turned off.
Recommendation: In a manual operation, if immersion in hot water is used for sanitizing, ensure: (1) the temperature of the water is maintained at 77°C (171°F) or above and (2) the food-contact surface is immersed for at least 30 seconds.
Item No.: 38
Site: Galley-Warewash
Violation: The grime remover unit was no longer used in the operation.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 40
Site: Buffet-Belvedere Port/Starboard Salad Station
Violation: Several dead flies were trapped in the long light fixtures on the employee's side of the buffet line.
Recommendation: Remove dead or trapped insects, rodents, and other pests from control devices and the vessel at a frequency that prevents their accumulation or decomposition or the attraction of other pests.
Item No.: 36
Site: Galley-Belvedere Ice Machine
Violation: The light intensity behind and around the ice machine was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Galley-Belvedere Port/Starboard International Counter
Violation: The light intensity in the corner at the end of the buffet line on the employee side of the buffet counter was less than 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 27
Site: Galley-Oriental Pantry Reach-in Refrigerator BE7
Violation: Water was dripping from the front left screw of the light fixture on the top of the right compartment of the reach-in refrigerator. A small pool of water had accumulated on the top shelf in the refrigerator, which had a hotel pan of parsley stored. The dripping water did not impact the parsley and two hotel pans of diced tomatoes stored under the top shelf. These food items were moved to the left compartment of the refrigerator, which was empty.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 19
Site: Galley-Belvedere Oriental Pantry Reach-in Refrigerator BE7
Violation: Water was dripping from the front left screw of the light fixture on the top of the right compartment of the reach-in refrigerator. A small pool of water had accumulated on the top shelf in the refrigerator, which had a hotel pan of parsley stored. The dripping water did not affect the parsley and two hotel pans of diced tomatoes stored under the top shelf. These food items were moved to the left compartment of the refrigerator, which was empty.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 36
Site: Galley-Belvedere Oriental Pantry
Violation: The light fixture above inside the canopy hood above the pasta cooking was missing. As a result, the light intensity was below 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 16
Site: Galley-Neptune Grill
Violation: The potentially hazardous food items, including tuna salad, raw codfish, and cut lettuce, on time control inside the time control refrigerator NG2 were not individually marked with a time control discard label. This outlet was open for longer than 4 hours.
Recommendation: If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
Item No.: 21
Site: Buffet-Neptune Grill
Violation: The ice/water dispenser was installed on the counter with less than a 100 mm (4-inch) clearance.
Recommendation: Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
Item No.: 33
Site: Bar-Neptune Bar
Violation: The deckhead above the bar had a circular design that was made with a soft vinyl material that was not hard, durable, or easily cleanable.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 36
Site: Pantry-Neptune Bar
Violation: The light intensity behind and around the ice machine was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 34
Site: Galley-Sindu Pot Wash
Violation: Water was leaking from the potable water supply line under the third compartment of the three-compartment sink.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
*Inspections scores of 85 or lower are NOT satisfactory