Item No.:
28
|
|
Site:
Galley-Rossiene
|
|
Violation:
A soiled trolley was stored adjacent in the clean area in the Rossiene Pantry. The area was in the process of cleaning up after breakfast.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
26
|
|
Site:
Buffet-Wide World
|
|
Violation:
One clear glass coffee mug was soiled and stored with the clean mugs at this beverage station.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 10
|
|
Violation:
While taking temperature measurements on rack type dishwasher 1SW10093126 it was discovered that a round waiter tray had become lodged under the spray rack in the front of the machine blocking water flow. Simultaneously, the crew member inspecting dishes at the machine exit discovered the dishes exiting the machine were not cleaned satisfactorily and was passing to the front to be rewashed. It appeared that any affected dishware was rewashed.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 10 Technical Compartment
|
|
Violation:
The deck inside the technical space below the high fog area contained standing water.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Freezer Area 940
|
|
Violation:
The condensate line in this area had leaked and frozen in a puddle around the piping into the deck.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
27
|
|
Site:
Galley-Pastry
|
|
Violation:
The nonfood contact area inside the 4 compartment deck oven contained soiled recessed hex screws that were difficult to clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
26
|
|
Site:
Buffet-Service Line
|
|
Violation:
During lunch service two previously cleaned plates under plastic protection on the line contained food debris.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
38
|
|
Site:
Provisions-Beer Tanks
|
|
Violation:
Two mops were stored wet and in a mop bucket not allowing them to air dry.
|
|
Recommendation:
After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
|
|
|
Item No.:
22
|
|
Site:
Pantry-Beach Bar
|
|
Violation:
The glass washer was under repair during the inspection.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Record Review - Pipe Maintenance and Repair
|
|
Violation:
The logs for the maintenance and repairs did not note that the final halogen residual was below or equal to 5.00 ppm after flushing and before placing back into service. The procedures followed by staff were correct but the documentation of this value was missing.
|
|
Recommendation:
Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
|
|