Item No.:
33
|
|
Site:
Buffet-Lounge Deck
|
|
Violation:
The coving at the deck/cabinet junctures throughout the area was either missing or worn away.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
21
|
|
Site:
Buffet-Lounge Deck
|
|
Violation:
In the technical spaces below the passenger handwashing stations, there were gaps and seams, raw wood, and the subfloor bottom was not easily cleanable.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
38
|
|
Site:
Buffet-Lounge Deck
|
|
Violation:
A bottle of refill soap and a spray bottle of stainless steel cleaner were stored in the technical space below the passenger handwash station closest to the beverage area. A bottle of multipurpose spray cleaner was stored in the technical space below the other passenger handwash station. Neither cabinet was labeled for cleaning material storage.
|
|
Recommendation:
Label the locker "CLEANING MATERIALS ONLY."
|
|
|
Item No.:
33
|
|
Site:
Buffet-Lounge Beverage/Waiter Station
|
|
Violation:
The coving at the deck/cabinet junctures was either missing or worn away.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
38
|
|
Site:
Buffet-Lounge Beverage/Waiter Station
|
|
Violation:
A refill bottle of soap and two bottles of cleaner for the coffee machine were stored in the technical space below the utility sink. The space was not labeled for cleaning material storage.
|
|
Recommendation:
Label the locker "CLEANING MATERIALS ONLY."
|
|
|
Item No.:
28
|
|
Site:
Buffet-Lounge
|
|
Violation:
Approximately 10 coffee carafes were stored in a closed cabinet with their lids closed and water was still inside. This was corrected.
|
|
Recommendation:
After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food. Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
33
|
|
Site:
Galley-Lounge Deck
|
|
Violation:
The top of the cove base was rough where it met the bulkhead from the anti-slip material throughout the galley.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
33
|
|
Site:
Galley-Lounge Deck
|
|
Violation:
The threshold at the entrance to the galley from the beverage/waiter station area was chipped and rough all along the area, including the recess for the door latch.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
32
|
|
Site:
Galley-Lounge Deck
|
|
Violation:
The waste bins in the galley had lids with a hole in the center that could not be covered.
|
|
Recommendation:
Ensure receptacles and waste-handling containers for refuse and recyclables and for use with materials containing food residue are insect and rodent resistant and have tight-fitting lids.
|
|
|
Item No.:
37
|
|
Site:
Galley-Lounge Deck
|
|
Violation:
Condensate was collected on a small area of the deckhead inside the exhaust hood above the dishwash machine. Condensate was also collected on the edge of the supply vent in front of the dishwash machine. Staff stated the machine hadn't been used in an hour and a half.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
26
|
|
Site:
Galley-Lounge Deck - Dishwash
|
|
Violation:
A pitcher stored on the clean storage rack was soiled at the spout with a white dried material.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-Lounge Deck - Dishwash
|
|
Violation:
A bowl stored on the clean storage rack had residue from a sticker on the outside.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Galley-Lounge Deck - Dishwash
|
|
Violation:
Two bowls on the clean storage rack were wet nested and not stored to allow proper air drying.
|
|
Recommendation:
After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food. Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
33
|
|
Site:
Galley-Lounge Deck
|
|
Violation:
A large amount of ice was accumulated on the deck below the three storage shelves closest to the evaporative condenser in the walk-in freezer. Staff stated the heating coil for the condenser drain line did not reach the top of the line, and when condensate from the adjacent walk-in refrigerator flowed into the drain, it overflowed onto the deck.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
19
|
|
Site:
Galley-Lounge Deck
|
|
Violation:
Several trays of frozen food were covered in a layer of ice from condensate issues inside the walk-in freezer. Technicians were onboard to work on the issue. Staff stated the food would be discarded.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
21
|
|
Site:
Galley-Lounge Deck
|
|
Violation:
Ice was accumulated on the some of the shelving units inside the walk-in freezer from condensate issues.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Upper Deck - Bonded Store
|
|
Violation:
The deckhead and bulkhead in this liquor store rooms was made of a soft material (A60) and not hard or durable. In addition, the open deckhead had wires, pipes, and cables that made cleaning difficult. There was no coving where the deck met the soft bulkheads. Finally, the cage-like bulkhead and door to the area was not easily cleanable.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure bulkheads and deckheads have smooth, hard finishes and light colored surfaces. Exception: bars may have decorative surfaces provided that they are easily cleanable.
|
|
|
Item No.:
31
|
|
Site:
Provisions-Upper Deck - Bonded Store
|
|
Violation:
The back part of the cleaning gear room was set up as a bonded store room for liquor with a cage-like bulkhead and door to separate it from the room. Cleaning chemicals and cabin toiletry amenities were stored in the front part of the room on the other side of the cage-like bulkhead.
|
|
Recommendation:
Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
38
|
|
Site:
Provisions-Upper Deck - Bonded Store
|
|
Violation:
A bag of decorative items was stored hanging on the top support of one of the liquor shelving units.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
21
|
|
Site:
Bar-Lounge Deck
|
|
Violation:
The cables and beverage lines in the undercounter technical space next to the ice machine were draping on the deck. In the same space, sthere was exposed raw wood above the undercounter ice machine. Finally, there was peeling sealant where the stainless steel profile met the counter lip above the ice machine.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
38
|
|
Site:
Bar-Lounge Deck
|
|
Violation:
Four bottles of laundry stain remover, a bottle of carpet cleaner, and a bottle of enzyme spray were stored in the cleaning locker. None of these items were used in the bar food area.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
20
|
|
Site:
Other-Lounge Foyer Self-Service Area
|
|
Violation:
Ice was accumulated on the back interior of the undercounter refrigerator. It was unclear if the condenser was frozen or if warm air was entering the refrigerator.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
|
|
|
Item No.:
33
|
|
Site:
Other-Lounge Foyer Self-Service Area
|
|
Violation:
The coving at the deck/cabinet junctures was either missing or worn away.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
21
|
|
Site:
Other-Lounge Foyer Self-Service Area
|
|
Violation:
The cables and beverage lines below the coffee machine were draping on the deck.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
38
|
|
Site:
Other-Lounge Foyer Self-Service Area
|
|
Violation:
Cleaning chemical for the coffee machines was stored in the technical space below the coffee machine. The cabinet was not labeled for cleaning material storage.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
33
|
|
Site:
Other-Lounge Foyer Self-Service Area
|
|
Violation:
The subfloor inside the technical space below the passenger handwash station was absorbent and not easily cleanable.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure bulkheads and deckheads have smooth, hard finishes and light colored surfaces. Exception: bars may have decorative surfaces provided that they are easily cleanable.
|
|
|
Item No.:
38
|
|
Site:
Other-Lounge Foyer Self-Service Area
|
|
Violation:
A bottle of refill soap and two chemical spray bottles were stored in the undercounter technical space below the passenger handwash station. The cabinet was not labeled for chemical storage.
|
|
Recommendation:
Label the locker "CLEANING MATERIALS ONLY."
|
|
|
Item No.:
*
|
|
Site:
Other-Sun Deck Barbecue
|
|
Violation:
The deckhead above where the sun deck barbecue grill would go was not stainless steel. This was discussed during the July 2017 construction inspection and staff stated it was expected to be installed during the October 2017 dry dock. Until the deckhead is installed, the grill will not be in use.
|
|
Recommendation:
Install a stainless steel deckhead.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point
|
|
Violation:
No high or low level alarm for free halogen residual was installed for the far point. When the inspector entered the area with the far point analyzer, the analyzer read over 12 ppm.
|
|
Recommendation:
Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen readings at the distant point analyzer.
|
|
|
Item No.:
04
|
|
Site:
Potable Water-Far Point
|
|
Violation:
When the inspector arrived in the area, the analyzer was reading over 12 ppm free halogen residual. The engineers were aware of this and explained that the levels of free halogen residuals for the past week and a half were peaking and dropping continuously. This was confirmed on the far point chart recorder charts. The ship's and the inspector's test kits both topped out at above 10 ppm when samples were taken. Within approximately 5 minutes the free halogen residual dropped below 5 ppm. Staff were unaware of what was causing the issue, but reported that a technician was scheduled to visit the ship at the end of the month to assess the system.
|
|
Recommendation:
Provide continuous halogenation of the potable water system using halogenation injection equipment and maintain a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point
|
|
Violation:
When the inspector arrived in the area, the analyzer was reading over 12 ppm free halogen residual. The engineers were aware of this and explained that the levels of free halogen residuals for the past week and a half were peaking and dropping continuously. This was confirmed on the far point chart recorder charts. The ship's and the inspector's test kits both topped out at above 10 ppm when samples were taken. Within approximately 5 minutes the free halogen residual dropped below 5 ppm. Staff were unaware of what was causing the issue, but reported that a technician was scheduled to visit the ship at the end of the month to assess the system.
|
|
Recommendation:
Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel. Complete repairs on malfunctioning halogen analyzer-chart recorders within 10 days of equipment failure.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Bunker Microbiological Testing
|
|
Violation:
The microbiologic reports from the ports where potable water bunkering had occurred were all greater than 30 days old and the staff onboard were not conducting microbiologic tests with the onboard test reagents.
|
|
Recommendation:
Where available, ensure the vessel has a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards. Ensure the date of the analysis report is 30 days or less from the date of potable water bunkering, and include an analysis for Escherichia coli at a minimum.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Microbiological Testing
|
|
Violation:
No UV lamp was onboard for testing the potable water microbiologic samples if a positive for total coliforms was indicated.
|
|
Recommendation:
If water samples are collected and analyzed by the vessel for the presence of E. coli, analyze the samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Ensure test kits, incubators, and associated equipment are operated and maintained in accordance with the manufacturers? specifications.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Test Results for RPZs
|
|
Violation:
The test results for the two reduced pressure zone assembly devices (potable to technical water and international shore connection) from when they were installed in the shipyard were not available on board the vessel.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device. Retain the inspection and test results for backflow prevention devices for at least 12 months and ensure they are available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Program
|
|
Violation:
The list of backflow prevention devices for the cabins, treatment rooms, and heads did not specify that the plumbing connection was the toilet.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-System Disinfection
|
|
Violation:
The documentation for the disinfection of the potable water distribution system did not include the number of hours the free halogen residual was 50 ppm or above.
|
|
Recommendation:
Ensure records are accurate and complete.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
The cooling logs for the last 30 days had many entries where the temperature measured after two hours was greater than 70°F. This included: pineapple cakes on 8/30, starting temperature of 165°F, two-hour temperature of 81°F and four-hour temperature of 40°F; pasta on 9/2, starting temperature of 185°F, two-hour temperature of 79°F and four-hour temperature of 39°F; puttanesca sauce on 8/19, starting temperature of 145°F, two-hour temperature of 80°F and four-hour temperature of 39°F; eggs on 8/20, starting temperature of 200°F, two-hour temperature of 100°F and four-hour temperature of 40°F; cheesecake on 8/23, starting temperature of 170°F, two-hour temperature of 82°F and four-hour temperature of 40°F; cheesecake on 8/15, starting temperature of 140°F, two-hour temperature of 75°F and four-hour temperature of 41°F; and clam chowder on 8/15, starting temperature of 141°F, two-hour temperature of 89°F and four-hour temperature of 37°F. In addition, the logs indicated bulgur was cooled on 8/27 with a starting temperature of 111°F and minestrone was cooled on 8/27 with a starting temperature of 120°F. Finally, blueberry compote was cooled on 8/26 with a starting temperature of 190°F, a two-hour temperature of 90°F, and no final four-hour temperature was recorded. All of the logs were signed by a supervisor.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
13
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
The cooling logs for the last 30 days had many entries where the temperature measured after two hours was greater than 70°F. This included: pineapple cakes on 8/30, starting temperature of 165°F, two-hour temperature of 81°F and four-hour temperature of 40°F; pasta on 9/2, starting temperature of 185°F, two-hour temperature of 79°F and four-hour temperature of 39°F; puttanesca sauce on 8/19, starting temperature of 145°F, two-hour temperature of 80°F and four-hour temperature of 39°F; eggs on 8/20, starting temperature of 200°F, two-hour temperature of 100°F and four-hour temperature of 40°F; cheesecake on 8/23, starting temperature of 170°F, two-hour temperature of 82°F and four-hour temperature of 40°F; cheesecake on 8/15, starting temperature of 140°F, two-hour temperature of 75°F and four-hour temperature of 41°F; and clam chowder on 8/15, starting temperature of 141°F, two-hour temperature of 89°F and four-hour temperature of 37°F. In addition, the logs indicated bulgur was cooled on 8/27 with a starting temperature of 111°F and minestrone was cooled on 8/27 with a starting temperature of 120°F. Finally, blueberry compote was cooled on 8/26 with a starting temperature of 190°F, a two-hour temperature of 90°F, and no final four-hour temperature was recorded. All of the logs were signed by a supervisor.
|
|
Recommendation:
Ensure the supervisor or person in charge of food operations on the vessel monitors that: (1) Food operations are not conducted in a room used as living or sleeping quarters; (2) Persons unnecessary to the food operation are not allowed in the food preparation, food storage, or warewashing areas. (3) Employees and other persons such as delivery and maintenance persons and pesticide applicators entering the food preparation, food storage, or warewashing areas comply with the guidelines in this manual; (4) Food employees are effectively cleaning their hands; (5) Employees are observing foods as they are received to determine that they are from approved sources, delivered at the required temperatures, protected from contamination, unadulterated, and accurately presented; (6) Employees are properly cooking potentially hazardous food, being particularly careful in cooking foods known to cause severe foodborne illness and death, such as eggs and comminuted meats; (7) Employees are using proper methods to rapidly cool potentially hazardous foods that are not held hot or are not for consumption within 4 hours; (8) Consumers who order raw or partially cooked ready-to-eat foods of animal origin are informed that the food is not cooked sufficiently to ensure its safety; (9) Employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused; (10) Consumers are notified that clean tableware is to be used when they return to self-service areas such as salad bars and buffets; (11) Employees are preventing cross-contamination of ready-to-eat food with bare hands by properly using suitable utensils such as deli tissue, spatulas, tongs, single-use gloves, or dispensing equipment; (12) Employees are properly trained in food safety, including food allergy awareness, as it relates to their assigned duties; (13) Food employees are informed of their responsibility to report to the supervisor or person in charge information about their health and activities as they relate to diseases that are transmissible through food. Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases that are transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of potentially hazardous food, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control pints in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
The cooling logs for the last 30 days had many entries where the temperature measured after two hours was greater than 70°F. This included: pineapple cakes on 8/30, starting temperature of 165°F, two-hour temperature of 81°F and four-hour temperature of 40°F; pasta on 9/2, starting temperature of 185°F, two-hour temperature of 79°F and four-hour temperature of 39°F; puttanesca sauce on 8/19, starting temperature of 145°F, two-hour temperature of 80°F and four-hour temperature of 39°F; eggs on 8/20, starting temperature of 200°F, two-hour temperature of 100°F and four-hour temperature of 40°F; cheesecake on 8/23, starting temperature of 170°F, two-hour temperature of 82°F and four-hour temperature of 40°F; cheesecake on 8/15, starting temperature of 140°F, two-hour temperature of 75°F and four-hour temperature of 41°F; and clam chowder on 8/15, starting temperature of 141°F, two-hour temperature of 89°F and four-hour temperature of 37°F. In addition, the logs indicated bulgur was cooled on 8/27 with a starting temperature of 111°F and minestrone was cooled on 8/27 with a starting temperature of 120°F. Finally, blueberry compote was cooled on 8/26 with a starting temperature of 190°F, a two-hour temperature of 90°F, and no final four-hour temperature was recorded. All of the logs were signed by a supervisor.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
33
|
|
Site:
Galley-Lounge Deck Hot Galley
|
|
Violation:
The cover grate for the deck sink was rough and difficult to clean at the metal junctures. Staff stated this was scheduled to be replaced.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan
|
|
Violation:
The plan did not include procedures for returning the vessel to normal operations after an outbreak or elevation. This was corrected.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Duties and responsibilities of each department and their staff for all the passenger and crew public areas; (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (5) Procedures for returning the vessel to normal operating conditions after an outbreak; (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
|
|
|