Cruise Ship: MSC Armonia Cruise Line: MSC Cruise Management (UK) Ltd Inspection Date: 01/06/2020 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 27
Site: Buffet-Deck 11 Lido Port and Starboard Serving Lines
Violation: A meat slicer designated as 'display only' was located on the food service side of the passenger buffet and soiled with a small accumulation of dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Galley-Warewashing
Violation: The rack type dishwash curtain separating the wash and final rinse compartments was curling, which could allow the wash cycle to contaminate the final rinse sanitization.
Recommendation: Ensure the warewashing machine wash and rinse tanks are equipped with baffles, curtains, or other means to minimize internal cross-contamination of the solutions in wash and rinse tanks.
Item No.: 28
Site: Galley-Deck 4 Dishwash
Violation: Five salad bowls had been recently cleaned and were nested upside down but were still wet on the inside and would not adequately air dry while stacked. Staff immediately corrected this.
Recommendation: After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food.
Item No.: 27
Site: Galley-Deck 4
Violation: The bowl mixer had some minor corrosion and debris on a non-food-contact surface. The inspector used an alcohol wipe on the surface, and it came back soiled with the debris. Staff responded immediately to have the equipment cleaned.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Galley-Deck 5 Dishwash
Violation: The conveyer belt type warewash dishwashing equipment was continuously dripping under the final rinse compartment and pooling on the deck. Staff responded immediately to have the water removed and the equipment was repaired before the end of the inspection.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 35
Site: Galley-Deck 5 Dishwash
Violation: The conveyer belt type warewash dishwashing equipment was continuously dripping under the final rinse compartment and pooling on the deck. Staff responded immediately to have the water removed and the equipment was repaired before the end of the inspection.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 26
Site: Galley-Deck 5 Ice Machine
Violation: The ice machine closest to the chef's office 'PASS Station7' had some floating black debris in the catch tray. Staff responded to have this immediately cleaned and the ice discarded.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Galley-Deck 5 Pastry
Violation: There were 10 slotted fasteners on the oven. All other fasteners on the oven had been changed to smooth. Staff immediately corrected this before the end of the inspection.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 21
Site: Galley-Deck 6 Wine Stand
Violation: There was a missing undercounter door. The exposed hinges were difficult to clean and soiled to the sight and touch. The space was used for dry storage of an unopened beverage. Staff stated that the door had been damaged and there was a work order to replace it.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Deck 6 Wine Stand
Violation: There was a missing undercounter door. The exposed hinges were difficult to clean and soiled to the sight and touch. The space was used for dry storage of an unopened beverage. Staff stated that the door had been damaged and there was a work order to replace it.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Bar-Deck 6 Rum Bar Pantry AFT
Violation: The ice machine had brown and pink debris in the catch tray. The inspector used an alcohol wipe and it became soiled by the debris. Staff responded to immediately have the equipment cleaned and the ice discarded.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 21
Site: Bar-Deck 6 Cafe San Marco FWD
Violation: The coffee maker drain line penetrating the counter had a rough, difficult to clean surface where the sealant had peeled away. The surface was clean at the time of the inspection. Staff responded to have this immediately corrected.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 02
Site: Medical-Acute Gastrointestinal (AGE) Questionnaire
Violation: The AGE Questionnaires for a passenger on December 14, 2019 and a crew member on December 15, 2019 did not have the designation as passenger or crew member completed. Staff had the passenger and crew member questionnaires in separate binders.
Recommendation: Distribute questionnaires detailing activities and meal locations for the 72 hours before illness onset to all passengers and crew members who are AGE CASES. Ensure that the self-administered questionnaires contain all of the data elements that appear in the questionnaire found in Annex 13.2.2. Ensure that completed questionnaires are maintained with the AGE surveillance log.
Item No.: 15
Site: Galley-Garde Manger Area
Violation: There was one canned good with a dented seam stored on the shelf in a walk-in dry storage room. Staff immediately discarded this.
Recommendation: Ensure food packages are in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Ensure canned goods with dents on end or side seams are not used.
Item No.: 08
Site: Potable Water-Bunker Pre-Test
Violation: No shore side chlorine or pH values were recorded prior to bunkering on 9 December 2019, 11 December 2019, and 16 December 2019.
Recommendation: Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections.
Item No.: 06
Site: Potable Water-Microbiologic Monitoring
Violation: The monthly random E. coli tests of the water system were not recorded in the log for the month of August 2019. Staff provided an email from the ship's public health officer to the chief engineer and staff captain stating that the E. coli tests for August were completed and negative, but the dates and location of the samples tested were not documented.
Recommendation: Maintain sample results onboard the vessel for at least 12 months and ensure they are available for review during inspections.
Item No.: 08
Site: Potable Water-Incinerator
Violation: Water was continuously dripping from the relief vent of the reduced pressure backflow assembly installed on the cold-water supply line to the pulper economizer tank. Also, the potable water lines before the reduced pressure backflow assemblies on both the hot-water and cold-water supply lines to the pulper economizer tank were not striped blue or blue/green/blue to indicate potable water.
Recommendation: Maintain backflow prevention devices in good repair. Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Item No.: 10
Site: Recreational Water Facilities-Sand Filter Core Sample Test
Violation: No sand filter core sample tests were documented for either the forward or aft swimming pool. The last documented sand filter core sample test for the whirlpool spa was 16 June 2019.
Recommendation: Examine granular filter media for channels, mounds, or holes. Inspect a core sample of the filter media for excessive organic material accumulation using a recommended sedimentation method. Inspections and sedimentation tests must be conducted quarterly for all RWFs. Change granular filter media for whirlpool spas and spa pools based on the inspection and sedimentation test results or every 12 months, whichever is more frequent. For all other RWFs, change granular filter media based on the inspection and sedimentation results or per the manufacturer?s recommendations, whichever is more frequent. Record the results of both the filter inspection and sedimentation test.
Item No.: 10
Site: Recreational Water Facilities-Sand Filter Housing Disinfection
Violation: The sand filter media for the forward swimming pool was changed on 25 November 2019, but the disinfection of the filter housing prior to adding the new sand was not documented. The sand filter media for the aft swimming pool was changed on 13 August 2019, but the disinfection of the filter housing prior to adding the new sand was not documented.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures. Ensure the filter housing must be cleaned, rinsed, and disinfected each time the filter media?including cartridge filter?is changed.
Item No.: 08
Site: Potable Water-Tank Disinfection
Violation: Potable water tanks 2112 and 2212 were inspected, cleaned, and sanitized on 11 December 2019, but the final chlorine value prior to placing the tanks back into service were not recorded.
Recommendation: Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service. Document the free halogen residual level.
Item No.: 10
Site: Recreational Water Facilities-Antientrampment Drain Covers
Violation: The antientrapment drain cover on the port side of the forward pool was missing one screw. The antientrapment drain cover on the starboard side of the aft pool was missing three screws. Both pools were open during the inspection and were immediately closed. Staff replace the missing screws, which was verified by the inspector, and reopened the pools by the end of the inspection.
Recommendation: For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency. Ensure all screws are installed on the antientrampment drain covers.
Item No.: 10
Site: Recreational Water Facilities-Shepherd's Hook
Violation: The shepherd's hook for the aft swimming pool had a rope on the end of the pool that was tied to railing where it was installed. This prevented easy access to the shepherd's hook in case of an emergency.
Recommendation: Provide a rescue or shepherd?s hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency.
Item No.: 05
Site: Potable Water-Distribution System Far Point
Violation: The inspector and crew member conducted six combined chlorine residual tests at the far point. The inspector's test results were 1.67 ppm, 1.60 ppm, and 1.75 ppm, and the crew member's test results were 1.70 ppm, 1.73 ppm, 1.70 ppm. The far point analyzer was consistently reading 2.21 ppm during all six tests. The far point analyzer was immediately recalibrated to 1.70 ppm.
Recommendation: Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 43
Site: Ventilation-Deck 12 AC Room 206
Violation: The condensation collection pan inside AC Unit 247 was not readily accessible for inspection, and no sight glass was installed. Staff stated that the ship had approximately 7 other AC units with not readily accessible condensation collection pans and no sight glass. However, staff also stated that the ship had an ongoing project to retrofit these AC units with easy-to-open doors to easily inspect the condensation collection pans. Staff provided documentation that five AC units had been retrofitted in January-February 2019, but no other retrofits had been completed since then. The ship did not have any documentation or schedule in-place regarding retrofitting the remaining seven AC units.
Recommendation: Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical.
Item No.: 42
Site: Children Area-Baby Club
Violation: No disinfectant was provided for the diaper changing station. The facility did have hand sanitizing wipes installed on the bulkhead near the diaper changing station, but these wipes were not EPA-registered disinfection wipes.
Recommendation: Include in each diaper changing station: (2) A supply of disposable diapers, gloves, wipes, table cleanser, and disinfectant.
*Inspections scores of 85 or lower are NOT satisfactory