Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Allure of the Seas Cruise Line: Royal Caribbean International Inspection Date: 02/12/2023 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Galley-Deck 3
Violation: On both the port and starboard ice machines, a bar code sticker was on the inside of the plastic ice deflector panel.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface.
Item No.: 22
Site: Galley-Deck 3 - Potwash
Violation: According to the hood-type potwash machine manufacturer's data plate, the wash times were 204, 324, and 444 seconds depending on the cycle selected. As the inspection team operated the machine at both cycles #1 and #2, the wash cycle was less than the specified time. For example, at cycle #2 (324 seconds = 5 minutes, 24 seconds), the wash cycle operated for 3 minutes, 40 seconds. The final rinse operated according to the manufacturer's specified time.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: 26
Site: Galley-Deck 5 - Dishwash
Violation: Old food debris and oily residue were on the bottom inside surface of three in-use clean plate trolleys.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Buffet-Windjammer - Portside Beverage Station
Violation: The juice dispenser splash area above the dispensing nozzle was soiled with more than a day's accumulation of dried juice residue. The crew started cleaning this immediately.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 32
Site: Pantry-Deck 5 - Champagne Bar
Violation: Receptacles containing food and beverage wastes were uncovered when not in use. The bar was in operation, but no crew members were in the pantry during the inspection.
Recommendation: Cover receptacles and waste-handling containers when not in continuous use and after they are filled.
Item No.: 33
Site: Galley-Deck 3
Violation: The lock was missing on the door to walk-in refrigerator #3955 and the inside walk-in freezer, exposing a hole.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 36
Site: Other-Deck 8 - Chop's Grille
Violation: The inspector measured 29 lux to the right of the coffee cup warming station.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program