Cruise Ship: Mariner of the Seas Cruise Line: Royal Caribbean International Inspection Date: 06/09/2023 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 39
Site: Dining Room-Deck 3 - Portside Aft Waiter Station
Violation: A small fly was observed in the area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Dining Room-Deck 3 - Portside Aft
Violation: The grout around the waiter station was missing.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Deck 3
Violation: The deckhead was leaking above the ice machine. Maintenance was in progress during the inspection.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 26
Site: Galley-Deck 3 - Beverage Station
Violation: The juice dispenser had more than a day's worth of food debris in the food splash zone.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 21
Site: Galley-Deck 3
Violation: The silicone on bulkhead junction behind the braising pans was missing, rough, and/or peeling.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 39
Site: Buffet-Deck 2 - Plate Cleaning
Violation: A fly was observed in the area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 26
Site: Buffet-Deck 2 - Beverage Station
Violation: The juice dispenser had more than a day's worth of food debris in the food splash zone.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-Deck 11 - Windjammer
Violation: The grouting on the deck was chipping and pitted in many areas near the tilting kettles.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 36
Site: Galley-Deck 11 - Windjammer
Violation: The deckhead light fixture near the potwash machine had multiple cracks on the cover shield.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 21
Site: Buffet-Deck 11 - Windjammer Jade Buffet Line (Starboard)
Violation: The underside metal housing for the top heat lamp was cracked leaving an open hole. No food was impacted.
Recommendation: Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 36
Site: Buffet-Deck 11 Windjammer Jade Buffet Line (Starboard)
Violation: The underside metal housing for the top heat lamp was cracked leaving an open hole. No food was impacted.
Recommendation: Protect an infrared or other heat lamp against breakage by a shield surrounding and extending beyond the bulb so only the face of the bulb is exposed.
Item No.: 30
Site: Other-Deck 5 - Crew Toilet Room
Violation: The men's toilet room did not have a tight-fitting self-closing door.
Recommendation: Ensure toilet rooms are completely enclosed and have tight-fitting, self-closing doors which are kept closed except during cleaning or maintenance.
Item No.: 11
Site: Medical-Acute Gastroenteritis (AGE) Isolation
Violation: A food employee had an onset of AGE symptoms on 20 May 2023 at 2000, but did not report to medical until 21 May 2023 at 1035. The employee's timecard indicated they had worked while symptomatic on 20 May 2023 from 0630 to 2247. A food risk assessment was completed, disciplinary action was taken, and the crew member received additional training.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. Ensure food employees who have conditions or symptoms of boils, open sores, infected wounds, diarrhea, jaundice, fever, vomiting, sore throat with fever, or discharges from the nose or mouth report these conditions or symptoms to the vessel's medical staff and are restricted from working with exposed food, warewashing, clean equipment, utensils, and linens, and unwrapped single-service and single-use articles.
Item No.: 08
Site: Potable Water-Evaporator #2
Violation: The relief vent for the reduce pressure zone (RPZ) assembly did not have a sufficient air gap. This was immediately corrected before the end of the inspection.
Recommendation: Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
Item No.: 07
Site: Potable Water-System Maintenance Disinfection Log
Violation: There were three entries in the log that documented 50ppm disinfection start and end times of only three hours, but the documented work description indicated disinfection time was for four hours. All three entries were during the ship's dry dock in March 2023. On 20 March 2023, the 50ppm start disinfection time was '4:00' and the end time was '7:00' for pipe replacement on deck 1 forward fire zone 2. On 18 March 2023, the 50ppm start disinfection time was '4:30' and the end time was '7:30' for replacing water valves on deck 10 forward fire zone 1. On 15 March 2023, the 50ppm start disinfection time was '4:30' and the end time was '7:30' for a pipe replacement on deck 10 fire zone 1. The work descriptions for all three entries correctly described disinfecting with 50ppm for four hours. Staff explained the recorded times were clerical errors.
Recommendation: Disinfect after potential contamination by increasing the free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.