Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Norwegian Sky Cruise Line: Norwegian Cruise Lines Inspection Date: 05/23/2024 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 35
Site: Pantry-Deck 11 - Top Siders Refrigerator 11480
Violation: Water pooled on the deck under the condenser unit. The drain line for the condenser was not positioned directly over the drain this was corrected. No food was impacted.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 39
Site: Bar-Deck 11 - Local Bar
Violation: A small fly was above the crew side register. The area was not in operation.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 19
Site: Buffet-Deck 11 - Garden Cafe Ice Cream Station
Violation: The two ice cream dipper wells were not fully protected by the sneeze guard.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 33
Site: Pantry-Deck 11 - Top Siders Refrigerator 11480
Violation: Water pooled on the deck under the condenser unit. The drain line for the condenser was not directly over the drain this was corrected. No food was impacted.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 33
Site: Bar-Deck 11 - Top Siders
Violation: The deck coving on the employee side was in disrepair.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 36
Site: Buffet-Deck 11 - Garden Cafe Main Service Line
Violation: The protective coating was peeling on the two lights above the hot plate. These were replaced immediately.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 39
Site: Dining Room-Deck 12 - Sushi
Violation: A small fly was in the area. The area was not in operation.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Bar-Deck 7 - Atrium
Violation: A small fly was in the area. The area was not in operation.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 21
Site: Bar-Deck 6 - Sugarcane
Violation: The underside of the service countertop on the employee side was in disrepair.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 33
Site: Provisions-Deck 2 - Wine Store Room
Violation: A gap was between two of the deckhead panels.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 08
Site: Potable Water-Cross Connection Log
Violation: The nontestable cross connection log was missing three additional backflow devices for the medical toilets and showers section. In addition, the log had the incorrect location names. Crew updated the list immediately.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location.
Item No.: 33
Site: Other-Deck 3- Engine Control Room- Coffee Station
Violation: An open penetration was not fully sealed on the bulkhead below the counter top. This was repaired immediately.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 27
Site: Other-Deck 3- Engine Control Room- Coffee Station
Violation: The countertop was soiled with food debris. Crew stated this station is no longer used.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program