Item No.:
19
|
|
Site:
Buffet-Pool Grill
|
|
Violation:
At the self-service buffet, 16 small bowls of cereal toppings such as nuts, seeds, and dried fruit were arranged four across and four deep. To reach the back row of bowls, the consumer would have to reach under the sneeze guard, by-passing the protection. The bowls were rearranged immediately and the issue was corrected.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
16
|
|
Site:
Buffet-Pool Grill
|
|
Violation:
A tray with 38 canapés (33 cheese crepe wraps and 5 bread rounds topped with tomato and cooked spinach) was found inside a cabinet labeled 'time control' stored on the outer deck between the pool grill and La Veranda outdoor passenger seating. The food items and the interior of the cabinet had a foul odor and the food items were cool to the touch and did not appear to be fresh. Staff stated the cabinet was stored in this area because it was not needed currently for the operation and had been there for approximately two weeks. The food items were discarded and the cabinet was cleaned and sanitized.
|
|
Recommendation:
If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (5) Is discarded within 4 hours of placement on time control.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Pool Grill
|
|
Violation:
The top of the cabinet stored on the outer deck between the pool grill and La Veranda outdoor passenger seating was loose and could be easily lifted to expose the insulation below. Staff stated this would be repaired.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
13
|
|
Site:
Buffet-Pool Grill
|
|
Violation:
A tray with 38 canapés (33 cheese crepe wraps and 5 bread rounds topped with tomato and cooked spinach) was found inside a cabinet labeled 'time control' stored on the outer deck between the pool grill and La Veranda outdoor passenger seating. The food items and the interior of the cabinet had a foul odor and the food items were cool to the touch and did not appear to be fresh. Staff stated the cabinet was stored in this area because it was not needed currently for the operation and had been there for approximately two weeks. The food items were discarded and the cabinet was cleaned and sanitized.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines.
|
|
|
Item No.:
33
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The deck tile had missing and recessed grout in front of the cooking equipment.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Compass Rose Wine Display
|
|
Violation:
There was no coving at the deck/cabinet juncture and in some areas there were seams between the deck tile and cabinet base. Clean food service items such as glasses and wine carafes were stored in the cabinets.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Compass Rose POS/Wine Station at Galley Entrance
|
|
Violation:
There was a large gap at the deck/wine cabinet juncture on the left side. The cove base piece was damaged in this area, and there was no coving along the entire length of the area. It appeared that the two wine refrigerators had shifted.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
27
|
|
Site:
Dining Room-Compass Rose POS/Wine Station at Galley Entrance
|
|
Violation:
The top edges of the four wine refrigerator doors were soiled with dust. This was corrected immediately.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
39
|
|
Site:
Galley-Bakery
|
|
Violation:
A large fly was in this area around the trolley of baked goods.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
33
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The deck tile had missing and recessed grout in this area.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
29
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
The handwash station at the soiled end of the flight-type conveyor warewash machine was blocked by racks of soiled dishes. The racks were moved.
|
|
Recommendation:
Ensure handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
Racks of soiled dishes blocked the handwash station at the soiled end of the flight-type conveyor warewash machine. The racks were moved.
|
|
Recommendation:
Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cold Galley
|
|
Violation:
The cooling times and temperatures of the prosciutto sandwiches with cut leafy greens and smoked salmon sandwiches, both prepared on September 20, were not recorded on a cooling log. The cook who prepared these two types of sandwiches explained the cooling procedure he followed, which included taking temperatures, but stated he forgot to record the items on the log.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 through the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
13
|
|
Site:
Galley-Cold Galley
|
|
Violation:
The cooling times and temperatures of the prosciutto sandwiches with cut leafy greens and smoked salmon sandwiches, both prepared on September 20, were not recorded on a cooling log. The cook who prepared these two types of sandwiches explained the cooling procedure he followed, which included taking temperatures, but stated he forgot to record the items on the log.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines.
|
|
|
Item No.:
21
|
|
Site:
Galley-Cold Galley
|
|
Violation:
The black plastic handle on the panini press was broken on the right side, which left a rough surface.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
37
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
Condensate collected on the exhaust hood, deckhead, and bulkhead at the soiled end of the rack-type conveyor dishwash machine. An excessive amount of steam was observed exiting the machine. It was determined that the fan on the exhaust was working, but the damper was not opening properly. The technical staff removed part of the damper to correct the issue and stated a permanent repair would be made the next day with a hot work permit.
|
|
Recommendation:
Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Deck 4 Loading Corridor
|
|
Violation:
Seven fully loaded pallets with bottled water, canned beverages, and boxed cereal were stored in this area under an open deckhead. The deckhead had pipes, cables and other difficult to clean features and the tops of some pipes were soiled with dust.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Deck 4 Loading Corridor
|
|
Violation:
Seven fully loaded pallets with bottled water, canned beverages, and boxed cereal were stored in this area under an open deckhead. The deckhead had pipes, cables and other difficult to clean features and the tops of some pipes were soiled with dust. Staff had covered the pallets with heavy black plastic wrap as an protective measure.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; and (6) At least 150 millimeters (6 inches) above the deck on shelving racks. Do not store foods: (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water Pipe Maintenance Records
|
|
Violation:
Potable water pipe maintenance records documenting the disinfection procedures for sections of piping replaced on 16 April, 23 March, and 24 March 2019 did not include the free halogen residual value prior to putting the sections of piping into service.
|
|
Recommendation:
Document the free halogen residual level.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water Pipe Maintenance Records
|
|
Violation:
A testable reduced pressure zone assembly backflow prevention device was replaced on the cold-water line in the Laundry room on 9/9/2019 and there was no disinfection record to document the device was properly disinfected prior to putting into service.
|
|
Recommendation:
Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Backflow Prevention Device Testing
|
|
Violation:
A reduced pressure zone assembly backflow prevention device was installed on the cold-water line in the Laundry room on 9/9/2019 and has not been tested to ensure proper functionality.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing (e.g., reduced pressure backflow prevention devices and pressure vacuum breakers) with a test kit after installation and at least annually. Maintain test results showing the pressure differences on both sides of the valves.
|
|
|
Item No.:
08
|
|
Site:
Other-Engine Room - Pipe Striping
|
|
Violation:
The newly installed piping for distillate and permeate water was not striped blue/gray/blue up to the chlorination injection point.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Identify all refrigerant brine lines and nonpotable chilled water lines in all food areas, such as on ice machines, ice cream machines, etc., with either ISO 14726 (blue/white/blue) or by another uniquely identifiable method to prevent cross-connections.
|
|
|
Item No.:
08
|
|
Site:
Other-Garbage Room - Pipe Striping
|
|
Violation:
The potable water lines for the trolley wash spray hose inside the Trolley Wash room adjacent the Cold Garbage room was not striped or identified as potable water.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Identify all refrigerant brine lines and nonpotable chilled water lines in all food areas, such as on ice machines, ice cream machines, etc., with either ISO 14726 (blue/white/blue) or by another uniquely identifiable method to prevent cross-connections.
|
|
|
Item No.:
34
|
|
Site:
Other-Garbage Room
|
|
Violation:
The handwash station in the main Garbage Room failed to drain properly after the water was engaged.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|