Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Norwegian Encore Cruise Line: Norwegian Cruise Lines Inspection Date: 01/03/2023 Inspection Score: 94
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 01
Site: Medical-24-Hour Report
Violation: During the 23 December 2022 - 3 January 2023 voyage, no 24-hour report was submitted prior to arrival in Saint Thomas, USVI on 31 December. The ship arrived in USVI from a foreign port. A 24-hour report was submitted prior to arrival in Miami on 3 January,
Recommendation: Ensure the master, medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port submits at least one standardized AGE report based on the number of reportable cases in the AGE log to VSP no less than 24 hours-but not more than 36 hours-before the vessel's expected arrival at the U.S. port.
Item No.: 07
Site: Potable Water-Bunker and Production Potable Water Lines
Violation: The bunker and production potable water lines had access spigots with threads. This allowed for the attachment of a hose, creating a cross-connection.
Recommendation: Ensure the potable water distribution system is maintained free of cross-connections. Remove the threads from the spigots.
Item No.: 08
Site: Potable Water-Pool Drain to Ballast System
Violation: The reduced pressure backflow prevention assembly for the pool drain to ballast system was dripping continuously. This assembly was pressure checked in August 2022. Remediation began immediately.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 10
Site: Recreational Water Facilities-Pools #1, #2, and Haven
Violation: The water fill level for all three recreational water facilities was insufficient and did not skim effectively (approximately 80%). This violation was noted in the 8 December 2019 construction inspection and had not been rectified. Multiple correspondence between the ship and the shipyard was documented.
Recommendation: For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Install surface skimmers or gutters capable of handling 100% of the filter flow of the recirculation system. If skimmers are used instead of gutters, install at least one skimmer for every 37 square meters (400 square feet) of pool surface area.
Item No.: 10
Site: Recreational Water Facilities-Octagon Spas
Violation: The manufactured antientrapment drain covers did not allow for complete water drainage. Additionally, the field fabricated drain covers did not have proper certification detailing that they were antientrapment.
Recommendation: Install drains in the recreational water facility system to allow for complete drainage of the entire volume of water from the pump, filter system, compensation or make-up tank, and all associated piping. Ensure the testing of manufactured drain covers is by a nationally or internationally recognized testing laboratory. Ensure the following information is stamped on each manufactured antientrapment drain cover: (1) certification standard and year; (2) type of drain use (single or multiple); (3) maximum flow rate (in gallons or liters per minute); (4) type of fitting (suction outlet); (5) life expectancy of cover; (6) mounting orientation (wall, floor, or both); (7) manufacturer's name or trademark; and (8) model designation. Ensure the design of custom/shipyard constructed (field fabricated) drain covers and suction fittings is fully specified by a registered design professional in accordance with ASME A112.19.8-2007. Ensure the specifications fully address cover/grate loadings, durability, hair, finger and limb entrapment issues, cover/grate secondary layer of protection, related sump design, and features specific to the RWF. Provide a letter from the shipyard for each custom/shipyard constructed (field fabricated) drain cover fitting. At a minimum, ensure the letter specifies the shipyard, name of the vessel, specifications and dimensions of the drain cover, as well as the exact location of the RWF for which it was designed. Ensure the name of and contact information for the registered design professional and signature are on the letter. Ensure antientrapment protection equipment (covers, suction fittings, safety vacuum release system, etc.) complies with ASME A112.19.8-2007-or any successor standards-whether the equipment is manufactured or field fabricated.
Item No.: 22
Site: Pantry-Housekeeping Deck 14
Violation: The starboard side pantry had an excess amount of soiled dishes and food stored in the clean area and on the sink landing. Staff stated they were from room service clearing the cabins during disembarkation. The inspector entered this area three hours after disembarkation ended.
Recommendation: Ensure soiled items to be cleaned in a warewashing machine are loaded into racks, trays, or baskets or onto conveyors in a position that (1) exposes the items to the unobstructed spray from all cycles; (2) allows the items to drain.
Item No.: 26
Site: Buffet-Deck 16 - Garden Cafe
Violation: Both starboard side juice machines were soiled with more than a day's accumulation of debris above the dispensing nozzles. The machines were cleaned before Inspector left the area.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 30
Site: Galley-Deck 6 - Pastry
Violation: Next to walk-in freezer D-06-6-005, the bucket fill faucet below the handwash station was dripping. Repairmen were working on the faucet before the inspector left the area.
Recommendation: Keep handwashing facilities clean and in good repair.
Item No.: 33
Site: Galley-Notice Boards
Violation: In some areas of the main galley and crew galley, loose papers were attached to the outside of the bulkhead-mounted display board, making cleaning difficult.
Recommendation: Ensure surfaces subject to routine splashes, spillage, or other soiling during normal use have easily cleanable features.
Item No.: 33
Site: Pantry-Deck 18 - Wave Bar
Violation: Water was leaking from the deckhead fire sprinkler collar onto the deck. The leak was fixed before the end of the inspection.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Notice Boards
Violation: In some areas of the main galley and crew galley, loose papers were attached to the outside of the bulkhead-mounted display board, making cleaning difficult.
Recommendation: Ensure surfaces subject to routine splashes, spillage, or other soiling during normal use have easily cleanable features.
Item No.: 39
Site: Preparation Room-Fish Preparation
Violation: Two live flies were in this room. The area was not in operation during the inspection. An exterminator immediately reported to the area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program