Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Carnival Celebration Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 03/15/2026 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 39
Site: Food Service General-Flies
Violation: Flies were found in the following food-service areas: Deck 16 - Big Chicken Galley - One fly above the flat-top grill. Deck 16 - Street Food Galley - One fly in the area. Deck 8 - Cucina del Capitano Galley - One fly around the counter-mounted mixer near the stacked ovens. Deck 8 - Bar 820 Pantry - One fly in the area. Deck 8 - Guy's Pig & Anchor - One fly was around the buffet line. Deck 8 - Deli Grill Pantry - One fly in the area. Deck 6 - Festivale Galley - One fly near the gelato machine and two near the utility sink.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item No.: 21
Site: Galley-Deck 17 - Guy's Burger Show Galley
Violation: The left hot plate's sealant was recessed and had more than a day's worth of food debris in the recess. The area was cleaned and sealant was reapplied before the end of the inspection.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Deck 17 - Guy's Burger Show Galley
Violation: The left hot plate's sealant was recessed and had more than a day's worth of food debris in the recess. The area was cleaned and sealant was reapplied before the end of the inspection.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Deck 16 - Blue Iguana Show Galley
Violation: The third from left hot plate sealant was recessed and had more than a day's worth of food debris in the recess. The area was cleaned and sealant was reapplied before the end of the inspection.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Deck 16 - Blue Iguana Show Galley
Violation: The third from left hot plates sealant was recessed and had more than a day's worth of food debris in the recess. The area was cleaned and sealant was reapplied before the end of the inspection.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 08
Site: Galley-Deck 8 - Guy's Pig & Anchor
Violation: The atmospheric air vents on the backflow prevention device for the prewash spray hose were clogged. This was corrected before the end of the inspection.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 20
Site: Preparation Room-Deck 4
Violation: The vegetable slicer machine had slotted fasteners on the food-contact surface.
Recommendation: Use low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 33
Site: Dining Room-Deck 4 - Team Dining - Hot Buffet Line - Aft
Violation: Water pooled on the deck beneath the buffet hot line. The source of the water was unknown.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 26
Site: Galley-Deck 6 - Emeril's Bistro
Violation: The salamander had more than a day's accumulation of food debris on the inner back wall of the equipment.
Recommendation: Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Galley-Deck 6 - Emeril's Bistro
Violation: The combination oven's back right leg was soiled with more than a day's accumulation of a yellow residue.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Pantry-Deck 6 - Latitude
Violation: A soiled knife and fruit peeler were stored in the reach-in refrigeration unit.
Recommendation: Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-Deck 6 - Soup Kettle Station #10
Violation: Water dripped from the technical compartment and pooled onto the deck.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Pantry-Deck 6 - Tropicale
Violation: Water pooled on the deck in front of the utility sink.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Pantry-Deck 6 - Tropicale
Violation: Condensate accumulated on the underside of the utility sink?s technical compartment, resulting in water pooling on the deck.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 21
Site: Galley-Deck 4
Violation: The blast chiller was out of order since the morning of the inspection.
Recommendation: Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.