Cruise Ship: Norwegian Bliss Cruise Line: Norwegian Cruise Lines Inspection Date: 08/22/2026 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Devices
Violation: Six non-testable backflow prevention devices in several food areas had blocked atmospheric vents: - Deck 3 - Poultry Preparation - One backflow prevention device had blocked vents with a white substance outside the poultry walk-in cooler. Corrective action began immediately. - Deck 6 - Starbucks - Four backflow prevention devices inside of the technical compartment serving the coffee machines and water refilling station had blocked vents with a solid yellow substance. - Deck 6 - The Manhattan Room - Bar Pantry - One backflow prevention device serving the ice machine had blocked vents with a solid yellow substance.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 14
Site: Galley-Deck 6 - Pastry
Violation: A crew member was wearing a silver ring with perforations along the band.
Recommendation: Ensure food employees, including bartenders, do not wear jewelry on their arms or hands while preparing food.
Item No.: 19
Site: Pantry-FD-14-6-007 Ice Machine
Violation: A box of bulk milk spilled onto four boxes of milk below and onto the deck.
Recommendation: Ensure food packages are in good condition and protect the integrity of the contents, so the food is not exposed to adulteration or potential contaminants. Ensure canned goods with dents on end or side seams are not used.
Item No.: 19
Site: Bar-Deck 15 - Observation Lounge
Violation: A lemon/lime juice bottle did not have a label identifying the common name of the food.
Recommendation: Ensure containers holding food or food ingredients removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
Item No.: 19
Site: Buffet-Deck 5 - Crew Mess - Island #1
Violation: A serving spoon was completely submerged in a pan of rice. This was corrected immediately.
Recommendation: During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container; (2) In food that is not TCS/PHF with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon; (3) On a clean portion of the food preparation table or cooking equipment only if the in-use utensil and the food-contact surface of the food preparation table or cooking equipment are cleaned and sanitized at least every 4 hours; (4) In running water of sufficient velocity to flush particulates to the drain (if used with moist food such as ice cream or mashed potatoes); (5) In a clean, protected location (if the utensils, such as ice scoops, are used only with a food that is not TCS/PHF); or (6) In a container of water (if the water is maintained at a temperature of at least 57°C [135°F] and the container is frequently cleaned and sanitized).
Item No.: 20
Site: Galley-Deck 8 - Food Republic - Show Galley
Violation: The combination oven probe was frayed and in disrepair.
Recommendation: Design and construct food-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Maintain food-contact equipment in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.
Item No.: 21
Site: Galley-Deck 8 - Cagney's Steakhouse - Show Galley
Violation: The sealant around the flat-top grill was in disrepair.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Buffet-Deck 16 - Garden Cafe - Beverage Station
Violation: Sealant was peeling and in disrepair around the front legs of the juice machine.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Deck 17 - American Diner
Violation: Wires were soiled and resting on the counter beneath the bains-marie.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Galley-Deck 5- Flight-type Warewash Machine
Violation: The flight-type warewash machine's wash compartment was soiled with rice, carrots, lettuce, and plastic debris. Corrective action began immediately.
Recommendation: Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw food, or laundering wiping cloths are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination and accumulation of debris and to ensure the equipment performs its intended function; (3) At least every 24 hours (if used).
Item No.: 22
Site: Galley-Deck 5- Flight-type Warewash Machine
Violation: One final sanitizing rinse spray nozzle on the bottom left spray arm was clogged and did not have a fan-like spray pattern. This was corrected immediately.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Pantry-FD-14-6-007 Ice Machine
Violation: Several auxiliary rinse spray nozzles were blocked on the top spray arm of the flight-type warewash machine. This was corrected immediately.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Pantry-FD-14-6-007 Ice Machine
Violation: The potwash machine's internal temperature gauge was inaccurate. The temperature gauge identified a final sanitizing rinse temperature of 215°F, while the plate surface temperature measured 164°F using a calibrated tip sensitive thermometer. The manifold temperature measured 201°F. Crew stated this was corrected prior to the end of the inspection.
Recommendation: Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine?s data plate and other manufacturer?s instructions. Ensure a warewashing machine?s conveyor speed or automatic cycle times is maintained accurately timed in accordance with manufacturer?s specifications. Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 23
Site: Galley-Deck 5- Flight-type Warewash Machine
Violation: The flight-type warewash machine's wash compartment was soiled with rice, carrots, lettuce, and plastic debris. Corrective actions began immediately.
Recommendation: Ensure food debris on equipment and utensils is scrapped over a waste disposal unit, pulper, or garbage receptacle or removed in a warewashing machine with a prewash cycle.
Item No.: 24
Site: Galley-Deck 6 - Potwash
Violation: The potwash machine's final sanitizing rinse manifold temperature measured above 194°F. Crew stated this was corrected before the end of the inspection.
Recommendation:
Item No.: 26
Site: Pantry-FD-14-6-007 Ice Machine
Violation: Black residue accumulated on the bottom and the top inside of the ice machine's evaporator panel cover. The cover was cleaned and sanitized before the end of the inspection.
Recommendation: Ensure food-contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils.
Item No.: 26
Site: Bar-Deck 17 - Le Bistro
Violation: A slotted fastener was in the food splash zone of the soda gun dispenser.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; (5) Accessible for cleaning and inspection by one of the following methods: without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 26
Site: Pantry-Deck 17 - Le Bistro
Violation: A piece of white debris was on the blast chiller probe.
Recommendation: Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils. Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Galley-Deck 17 - American Diner
Violation: Wires were soiled and resting on the counter beneath the bains-marie.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 30
Site: Galley-Deck 6 - Potwash
Violation: The handwashing station adjacent to the dirty end of the flight-type warewash machine did not have a 'wash hands often' sign. This was corrected immediately.
Recommendation: Post a sign over handwashing sinks stating "wash hands often," "wash hands frequently," or similar wording in a language the food employees understand.
Item No.: 33
Site: Galley-Deck 6 - Potwash
Violation: Water accumulated inside the deckhead light fixture above the dirty end of flight-type warewash machine. Additionally, a black mold-like residue was on the inside of the light shield.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Bar-Deck 6 - Atrium Bar
Violation: The back bar shelving with open liquor bottles did not have coving.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, counter/bulkhead/backsplash, and deck sink coaming/deck junctures in galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, scrapping stations, food storage rooms, food transportation corridors, equipment or utensil storage rooms, and toilet rooms intended for use by food employees.
Item No.: 33
Site: Bar-Deck 6 - Social Bar
Violation: The back bar shelving with open liquor bottles did not have coving.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, counter/bulkhead/backsplash, and deck sink coaming/deck junctures in galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, scrapping stations, food storage rooms, food transportation corridors, equipment or utensil storage rooms, and toilet rooms intended for use by food employees.
Item No.: 33
Site: Provisions-Deck 3 - Dairy Room
Violation: Milk pooled on the deck below a damaged box of milk.
Recommendation:
Item No.: 33
Site: Galley-Deck 17 - American Diner Show Galley
Violation: Water pooled on the deck at the entrance to the show galley.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 36
Site: Galley-Deck 17 - American Diner Show Galley
Violation: The light intensity measured less than 220 lux in front of the reach-in refrigeration unit.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot-candles) on food preparation surfaces. Ensure the light intensity is at least 220 lux (20 foot-candles) as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 38
Site: Galley-Deck 6 - Room Service
Violation: A wet mop was stored inside the cleaning locker with the mop head resting on the bottom. This was corrected immediately.
Recommendation: After use, ensure mops are placed in a position that allows them to air dry without soiling walls, equipment, or supplies.
Item No.: 39
Site: Dining Room-Deck 6 - Teppanyaki Table #9
Violation: One small fly was flying over the flat top grill. The venue was not in operation at the time of the inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item No.: 39
Site: Preparation Room-Deck 4 - Poultry
Violation: One small fly was near the utility sink.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.