Cruise Ship: Ovation of the Seas Cruise Line: Royal Caribbean International Inspection Date: 09/13/2026 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Galley-Deck 14 - Windjammer Hot Galley
Violation: An open seam was at the top of the grease chute compartment of the flat top and grooved top grill.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 28
Site: Galley-Deck 14 - Coastal Kitchen
Violation: Previously cleaned and sanitized utensils were stored in a soiled container. The container was taken away to be recleaned and sanitized.
Recommendation: Store cleaned equipment and utensils: (1) In a clean, dry location; (2) In a location where they are not exposed to splash, dust, or other contamination.
Item No.: 27
Site: Galley-Deck 14 - Fish and Chips
Violation: More than a day's accumulation of grease residue was on the exhaust hood overhang above the deep fat fryers. This was cleaned immediately.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Deck 14 - Solarium
Violation: More than a day's accumulation of grease residue was on the exhaust hood overhang above the deep fat fryers. This was cleaned immediately.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Pantry-Deck 14 - Pool Bar
Violation: Food debris blocked two of the wash spray nozzles of the hood-type glasswash machine. This was cleaned immediately.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction. Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw food, or laundering wiping cloths are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination and accumulation of debris and to ensure the equipment performs its intended function; (3) At least every 24 hours (if used).
Item No.: 36
Site: Galley-Deck 5 - Izumi
Violation: The light intensity measured less than 110 lux on the left side of the counter-mounted combination oven near the flat-top grill.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot-candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 27
Site: Galley-Deck 5 - Izumi Teppanyaki
Violation: Food and grease residue was on the previously cleaned and sanitized exhaust hood overhang for the flat top grill. This was cleaned immediately.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 36
Site: Buffet-Deck 2 - Hot Buffet Line
Violation: The protective coating was cracked and peeling on the far-left light bulb above the buffet line. The light bulb was immediately replaced.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter resistant in areas with exposed food; clean equipment, utensils, and linens; or unwrapped single-service articles and single-use articles. Protect an infrared or other heat lamp against breakage by a shield surrounding and extending beyond the bulb so only the face of the bulb is exposed.
Item No.: 21
Site: Bar-Deck 5 - Giovanni's Wine Bar
Violation: Several open seams were between the backsplash's joints along the back bar counter.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 08
Site: Potable Water-Deck 6- Fan Room Unit 06.1
Violation: The potable water line used to clean the AC units was not striped blue/green/blue or blue to indicate potable water. This was corrected before the end of the inspection.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines, including potable water supply lines in technical lockers, at 5-meters (16.4 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Identify all refrigerant brine lines and nonpotable chilled water lines in all food areas, such as on ice machines, ice cream machines, etc., with either ISO 14726 (blue/white/blue) or by another uniquely identifiable method to prevent cross-connections.
Item No.: 11
Site: Medical-Acute Gastroenteritis (AGE) Case Isolation
Violation: A food employee reported to work and visited the crew mess after an onset of AGE symptoms. On 8 August 2026, the crew member had an onset of symptoms at 1000. According to the crew member's time card, they worked from 1023-1409 and again starting at 1443. The crew member also went to crew mess for lunch. The crew member reported to medical at 1620.
Recommendation: When food employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) Follow-up with and receive approval by designated medical personnel before returning crew to work; (3) Document date and time of last symptom and clearance to return to work; (4) Review [when possible] any reportable AGE cases among passengers or crew reported after the food employee's illness onset for epidemiologic link/connection. Ensure the food employee's supervisor or person in charge conducts an assessment of food prepared or served by the food employee while symptomatic and take appropriate corrective actions. Document corrective actions taken as a result of the assessment.