Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seven Seas Explorer Cruise Line: Regent Seven Seas Inspection Date: 09/12/2026 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Galley-Deck 11 Pool Grill
Violation: The walk-in refrigerator had been out of order for approximately five days.
Recommendation: Maintain food-contact equipment in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.
Item No.: 39
Site: Buffet-Deck 11 Pool Grill
Violation: One small fly was flying near the entrance to the pantry.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item No.: 33
Site: Buffet-Deck 11 Pool Grill
Violation: The laminate on the door leading from the buffet to the galley pantry was in disrepair and peeling, which created a rough and difficult-to-clean surface.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 21
Site: Buffet-Deck 11 Pool Grill
Violation: An open penetration to a void space was in the preparation countertop near the back right leg of the sandwich toaster oven.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance. Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.
Item No.: 21
Site: Dining Room-Deck 11 La Veranda
Violation: Room service trolley #7 stored near the portside forward waiter station was in disrepair along all the edges, which exposed difficult-to-clean wood.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance. Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.
Item No.: 36
Site: Dining Room-Deck 11 La Veranda
Violation: The light intensity measured less than 220 lux at the portside aft waiter station when set on the brightest setting.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot-candles) during cleaning operations in bars and dining room waiter stations which includes open shelves (such as shelves without doors or shutters) where food and beverages are stored.
Item No.: 36
Site: Galley-Deck 11 La Veranda Cold Pantry
Violation: The heat lamp bulb's shatter resistant coating had peeled off in the center of the bulb.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter resistant in areas with exposed food; clean equipment, utensils, and linens; or unwrapped single-service articles and single-use articles. Protect an infrared or other heat lamp against breakage by a shield surrounding and extending beyond the bulb so only the face of the bulb is exposed.
Item No.: 33
Site: Food Service General-Painted Decks
Violation: The painted decks were in disrepair throughout the galleys, including deck 10 specialty galley, deck 4 main galley and crew galley, and deck 3 preparation rooms. Crew stated the decks will be replaced during their upcoming crossing.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 20
Site: Galley-Deck 4 Room Service
Violation: The bulk coffee container had two slotted screws in the food splash area.
Recommendation: Use low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 16
Site: Galley-Deck 4 Walk-In Refrigerator
Violation: The onion soup that was cooked on 9 September 2026 and cooled properly per the cooling logs measured 43.2°F with the crew's thermometer and 43.6°F with the inspector's thermometer.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain TCS/PHF at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 33
Site: Provisions-Deck 2 Dry Store
Violation: The decks throughout the dry store were excessively soiled with old food debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 01
Site: Medical-Acute Gastroenteritis (AGE) Reports
Violation: The total number of crew and passengers documented on the 24-hour AGE report for three separate voyages were not the total numbers from the beginning of the voyage. * Voyage Exp260729: The AGE surveillance log documented 726 passengers and 553 crew at the beginning of the voyage. The 24-hour AGE report documented 723 passengers and 554 crew. * Voyage Exp260812: The AGE surveillance log documented 720 passengers at the beginning of the voyage. The 24-hour AGE report documented 716 passengers. * Voyage Exp260909: The AGE surveillance log documented 711 passengers at the beginning of the voyage. The 24-hour AGE report documented 709 passengers.
Recommendation: Ensure the AGE report contains the following: (1) Name of the vessel; (2) Port of embarkation; (3) Date of embarkation; (4) Port of disembarkation; (5) Date of disembarkation; (6) Total number of reportable AGE cases among passengers, including those who have disembarked because of illness?even if the number is 0 (zero reporting); (7) Total number of reportable AGE cases among crew members, including those who have disembarked because of illness?even if the number is 0 (zero reporting); and (8) Total number of passengers and crew members on the cruise.
Item No.: 10
Site: Housekeeping-Heated Jetted Tub Disinfection
Violation: Cleaning and disinfection records indicated the heated jetted tub was not cleaned and disinfected on 29 July 2026.
Recommendation: Implement one of the following procedures for heated jetted tubs: (1) Drain, clean, and disinfect heated jetted tubs daily. Install a safety sign at the tub entrance advising users that using heated jetted tubs without the use of automated halogen and pH control may increase the risk of respiratory infections. (2) With an approved variance, drain heated jetted tubs every 3 days. Clean and disinfect tubs twice a week or between occupancies, whatever is more frequent. No signage is required.
Item No.: 40
Site: Integrated Pest Management-Rat Guards
Violation: Four portside rat guards, one on the forward and three on the aft mooring lines, were not positioned in a manner to prevent pest entry. All four rat guards had openings around a portion of the line.
Recommendation: Protect entry points where pests may enter the food areas. Ensure rat guards are made of a durable and nonchewable material. Use rat guards according to the manufacturer?s specifications for the effective prevention of pest migration. Ensure rat guards are on all lines that go ashore on arrival and until 1 hour before the ship leaves port. Ensure each line has at least one rat guard placed either as far as practicable from the pier or as far as practicable from the ship but still close enough to stuff any openings with nonchewable material. Ensure rat guards are not staggered on adjacent lines, and a group of lines do not merge onto one rat guard.
Item No.: 06
Site: Potable Water-Legionella Recreational Water Sampling
Violation: The recreational water facilities and heated jetted tubs were not sampled for legionella in June per the quarterly requirement. Crew stated they were transitioning to a new third party contractor and missed the window to sample. Sampling was subsequently conducted in September 2026.
Recommendation: Sample all spa pools, whirlpool spas, and heated jetted tubs for Legionella at least every 3 months. If Legionella is found, conduct follow-up sampling. Collect samples at least 48 hours after the facility has been restored to normal operating conditions after remediation. Note: Ships may test for Legionella every 6 months if the following criteria are met for the 24 previous months: (1) Negative Legionella test results for the spa pools, whirlpool spas, and heated jetted tubs; (2) No legionellosis cases associated with travel on the ship (including after-cruise travel-associated cases identified by public health authorities).
Item No.: 10
Site: Recreational Water Facilities-Deck 11 Main Pool
Violation: The water at the beach access level was unable to be skimmed across the entire perimeter of the pool.
Recommendation: For RWFs with skim gutters, ensure the water level reaches at least the skim gutter or overflow level for a portion of the pool perimeter to remove floating debris and the top portion of the pool water for treatment.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program