Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Norwegian Encore Cruise Line: Norwegian Cruise Lines Inspection Date: 09/15/2026 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Galley-Deck 16 - Garden Cafe Starboard Wok Station
Violation: The deck tile grout was recessed in front of the back counter.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 22
Site: Galley-Deck 16 - Garden Cafe Dishwash
Violation: One of the two flight-type dishwash machines had been out of order since 6 September 2026. Staff stated they were waiting for parts to repair the control panel.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Deck 18 - Haven Potwash Three-Compartment Sink
Violation: The sanitizing compartment's temperature gauge was not properly calibrated. The inspector measured the water temperature to be 188°F while the gauge read approximately 200°F.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 11
Site: Medical-Food Assessment Log
Violation: A food employee with acute gastroenteritis on 12 August 2026 had a food assessment filled out by their supervisor that explained what happened with the employee before they came to work and when they left work, but did not explain what the employee was doing while working or if the area was cleaned and sanitized.
Recommendation: Ensure the food employee's supervisor or person in charge conducts an assessment of food prepared or served by the food employee while symptomatic and take appropriate corrective actions. Document corrective actions taken as a result of the assessment.
Item No.: 13
Site: Preparation Room-Deck 4 - Butcher
Violation: When the inspection team entered the area, a crew member was standing in their socks on a preparation countertop wiping the deckhead above. The inspector had to prompt the crew to sanitize the countertop. The area was not in operation.
Recommendation: Ensure the supervisor or person in charge of food operations on the vessel monitors that: (1) Employees and other persons such as delivery and maintenance persons and pesticide applicators entering the food preparation, food storage, or warewashing areas comply with these standards; (2) Employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused; (3) Employees are properly trained in food safety as it relates to their assigned duties.
Item No.: 27
Site: Preparation Room-Deck 4 - Butcher
Violation: The preparation countertop was soiled by a crew member standing on top of it in their socks to wipe the deckhead above. The area was not in operation.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 14
Site: Galley-Deck 5 - Three-Compartment Sink
Violation: Red food debris was on the bottom of the clean-side crew member's apron. The crew member changed their apron.
Recommendation: Ensure food employees wear a clean uniform or apron to prevent contamination of food, equipment, utensils, linens, and single service and single-use articles.
Item No.: 20
Site: Buffet-Deck 5 - Beverage Station
Violation: Two slotted fasteners were on the food-splash zone near the espresso machine's nozzle. The fasteners were replaced.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; (5) Accessible for cleaning and inspection by one of the following methods: without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 12
Site: Galley-Deck 5 - Dishwash
Violation: After properly washing their hands, a crew member working on the clean side of the warewashing machine blew into their gloves before donning them. The crew member rewashed their hands and donned a new pair of gloves.
Recommendation: Ensure food employees clean their hands and exposed portions of their arms immediately before engaging in food preparation, including working with exposed food, clean equipment and utensils, and unwrapped single-service and single-use articles and: (1) After touching bare human body parts other than clean hands and clean, exposed portions of arms; (2) After using the toilet room; (3) After coughing, sneezing, using a handkerchief or disposable tissue, using tobacco, eating, or drinking; (4) After handling soiled equipment or utensils; (5) During food preparation, as often as necessary to remove soil and contamination and to prevent cross-contamination when changing tasks; (6) When switching between working with raw food and working with ready-to-eat food; (7) Before putting on gloves for working with food or clean equipment and between glove changes; and (8) After engaging in other activities that contaminate the hands.
Item No.: 13
Site: Galley-Deck 5 - Dishwash
Violation: After properly washing their hands, a crew member working on the clean side of the warewashing machine blew into their gloves before donning them. The crew member rewashed their hands and donned a new pair of gloves.
Recommendation: Ensure the supervisor or person in charge of food operations on the vessel monitors that: (1) Employees and other persons such as delivery and maintenance persons and pesticide applicators entering the food preparation, food storage, or warewashing areas comply with these standards; (2) Food employees are effectively cleaning their hands.
Item No.: 33
Site: Galley-Deck 6 - Hot Galley and Service Lines
Violation: The deck grout was recessed throughout the area.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 39
Site: Galley-Deck 6 - Dishwash
Violation: One fruit fly was near the handwashing sink.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item No.: 33
Site: Galley-Deck 6 - Flight-type Glasswash Machine
Violation: Condensate collected on the deckhead and dripped onto the soiled side of the flight-type glasswash machine below.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 37
Site: Galley-Deck 6 - Flight-type Glasswash Machine
Violation: Condensate collected on the deckhead and dripped onto the soiled side of the flight-type glasswash machine below.
Recommendation: Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and to remove contaminants generated by equipment located under them.
Item No.: 22
Site: Galley-Deck 6 - Flight-type Dishwash Machine
Violation: No water sprayed out of the top left side final rinse spray nozzle. This was corrected.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Deck 6 - Three-Compartment Sink
Violation: The sanitizing compartment's temperature gauge was not properly calibrated. The inspector measured the water temperature to be 208°F while the gauge read approximately 185°F.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 33
Site: Preparation Room-Deck 5 - Walk-in Freezer
Violation: Ice accumulated around the bulkhead-mounted speaker and ambient air thermometer.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 28
Site: Galley-Deck 6 - Teppanyaki
Violation: A crew member stood on the clean dish storage rack full of clean dishes directly across from the potwash, to investigate a leak. The area was in operation.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service articles and single-use articles: (1) In a clean, dry location; (2) In a location where they are not exposed to splash, dust, or other contamination; (3) At least 150 millimeters (6 inches) above the deck unless in packages on pallets, skids, or racks, which may be 127 millimeters (5 inches) above the deck.
Item No.: 13
Site: Galley-Deck 6 - Teppanyaki
Violation: A crew member stood on the clean dish storage rack directly across from the potwash to investigate a leak. There were clean dishes stored on the rack. The area was in operation.
Recommendation: Ensure the supervisor or person in charge of food operations on the vessel monitors that: (1) Employees and other persons such as delivery and maintenance persons and pesticide applicators entering the food preparation, food storage, or warewashing areas comply with these standards; (2) Employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused; (3) Employees are properly trained in food safety as it relates to their assigned duties.
Item No.: 27
Site: Galley-Deck 6 - Teppanyaki
Violation: The clean dish storage rack directly across from the potwash was soiled by a crew member's feet when they stood on it to investigate a leak. There were clean dishes stored on the rack. The area was in operation.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Galley-Deck 6 - Teppanyaki
Violation: The hood-type potwash machine was initially out of service due to a leak when the inspection team entered the area. Crew reported the machine was operational and the leak was fixed prior to the end of the inspection.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Deck 6 - The Local Three-Compartment Sink
Violation: The temperature gauge on the sanitizing compartment was filled with water and unreadable.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program