Item No.:
33
|
|
Site:
Buffet-Deck 5
|
|
Violation:
Standing water pooled in the open technical space below the bains-marie. This was immediately corrected.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are corrosion resistant. Install exposed utility service lines and pipes, including lines for fire detection and protection systems, so they do not obstruct or prevent cleaning.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Deck 5
|
|
Violation:
Sealant was missing and peeling around the legs of the sneeze guards. This was immediately corrected.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
37
|
|
Site:
Galley-Deck 5 - Hot Galley
|
|
Violation:
The stainless-steel bulkhead behind the tilting pan had an accumulation of condensate. This was immediately corrected.
|
|
Recommendation:
Ensure all food preparation, warewashing areas, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and to remove contaminants generated by equipment located under them.
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 5
|
|
Violation:
The light intensity in front of the refrigeration unit measured less than 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux on food preparation surfaces.
Ensure the light intensity is at least 220 lux as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 5 - Pastry
|
|
Violation:
A previously cleaned and sanitized chocolate machine nozzle had residual chocolate inside. This was immediately corrected.
|
|
Recommendation:
Ensure food-contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of cleaned and sanitized equipment and utensils.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Deck 4 - Frozen Poultry
|
|
Violation:
Two deckhead light covers had ice inside. This was immediately corrected.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Deck 4 - Refrigerated Poultry
|
|
Violation:
Two light covers contained standing water and ice inside. This was immediately corrected.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Deck 4 - Cooked/Smoked Fish Freezer
|
|
Violation:
One light cover had ice inside. This was immediately corrected.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 5 - International Cafe
|
|
Violation:
The undercounter warewash machine's food strainer was soiled with mint leaves and food debris. This was immediately corrected.
|
|
Recommendation:
Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw food, or laundering wiping cloths are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination and accumulation of debris and to ensure the equipment performs its intended function; (3) At least every 24 hours (if used).
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 5 - International Cafe
|
|
Violation:
The upper left corner of the ice machine's technical space had a black residue.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 5 - 360 Restaurant
|
|
Violation:
Sealant peeled along the front of the flat-top grill.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Other-Deck 5 - Biodigester Room
|
|
Violation:
The biodigester leaked a brown substance on the deck throughout the room. This was immediately corrected.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
Two reportable AGE passenger cases on 04 August 2026 and 06 August 2026 did not have body temperatures documented on the log. Additionally, no comments/notes were annotated to explain why a body temperature was not recorded. Crew shared a document on the electronic health record system explaining why the body temperature was not evaluated for both passengers.
|
|
Recommendation:
Ensure the AGE surveillance log includes a header containing the following information about the voyage: (1) Vessel name; (2) Voyage number; (3) Date from; (4) Date to; (5) Total number of passengers; (6) Total number of reportable AGE cases among passengers; (7) Total number of crew; (8) Total number of reportable AGE cases among crew.
Ensure the total number of passengers and total number of crew are the totals at the beginning of the voyage (i.e., totals on ?date from?).
Ensure the AGE surveillance log entry for each passenger or crew member contains the following information in separate columns: (1) Patient I.D.; (2) Date of the first medical visit or report to staff of illness; (3) Time of the first medical visit or report to staff of illness; (4) Person's last name; (5) Person's first name; (6) Person's age; (7) Person's sex; (8) Designation as passenger or crew member; (9) Cabin number; (10) Crew member position or job on the vessel; (11) Date of illness onset; (12) Time of illness onset; (13) Illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) Number of episodes of diarrhea in a 24-hour period; (b) Bloody stools (yes/no); (c) Number of episodes of vomiting in a 24-hour period; (d) Fever (yes/no); (e) Recorded temperature; (f) Abdominal cramps (yes/no); (g) Headaches (yes/no); (h) Myalgia (yes/no); (14) Date of last symptom; (15) Time of last symptom; (16) Entry (yes/no) for whether a specimen was requested; (17) Entry (yes/no) for whether a specimen was received; (18) Entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (19) Entry (yes/no) for whether this was a reportable AGE case; (20) Presence of underlying medical conditions that may affect interpretation of AGE; for example, diabetic diarrhea, inflammatory bowel disease, gastrectomy, antibiotic-induced diarrhea, vomiting from chemotherapy, ear infections in children or others. If none, write "none," "not applicable," "N/A," or similar wording.
Ensure the AGE surveillance log contains the above information in the exact order. Complete all fields of the AGE surveillance log, even if entry is zero or nonapplicable. If a field is not completed, document the reason in the notes column (for example, a virtual consultation).
Ensure the log data is exported in an analyzable form (such as Microsoft Excel or Microsoft Access) in the exact order noted above. Ensure any additional data fields in the surveillance log are entered only outside of the form margins when exported.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Control Log
|
|
Violation:
One nontestable backflow prevention device for four utility sinks in the deck 4 fire zone 5 hotel chemical locker had a recorded inspection date of 06 May 2024 exceeding the annual visual inspection time frame.
|
|
Recommendation:
Inspect backflow prevention devices periodically and replace any failed units. Complete a visual check for all nontestable backflow prevention devices and air gaps at least annually.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Deck 16 - World Market Middle Desert Station
|
|
Violation:
The tops of the two counter-mounted glass display cases were soiled with more than a day's accumulation of dust. Crew initiated corrective action.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Deck 16 - World Market Middle Hot Station
|
|
Violation:
The light intensity at the buffet serving line storing chicken sandwiches measured less than 220 lux. Crew initiated corrective action.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux on food preparation surfaces.
Ensure the light intensity is at least 220 lux as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Deck 16 - World Market Middle Meat Station
|
|
Violation:
No serving utensil was provided for a tray of cold-cut meats offered for consumer self-service at the buffet line.
|
|
Recommendation:
Provide a food-dispensing utensil for each container of food displayed at a consumer self-service unit such as a buffet or salad bar.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Deck 16 - World Market Portside Pasta Station
|
|
Violation:
The bulkhead tiles behind the entrance to the crew service area were chipped and cracked, creating difficult-to-clean surfaces.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 16 - World Market Scullery
|
|
Violation:
The decorative food-contact surfaces of four dishes stored on the clean storage rack were peeling and delaminating, creating difficult-to-clean surfaces. Crew initiated corrective actions.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food-contact surfaces of equipment must be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. Design and construct food-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; (5) Accessible for cleaning and inspection by one of the following methods: without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 16 - World Market Scullery
|
|
Violation:
The food-contact surfaces of four previously cleaned and sanitized glasses stored on the clean storage rack were soiled with more than a day's accumulation of yellow food residue. Crew initiated corrective action.
|
|
Recommendation:
Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 16 - World Market Scullery
|
|
Violation:
The starboard flight-type warewashing machine spewed water from the soiled end, causing water to accumulate on the deck in front. Crew placed buckets underneath the soiled side of the machine to collect the gray water that was discharging. The left bucket was overflowing with water, which pooled on the deck in front of the soiled end. Crew used mops to direct the gray water into the scupper. A crew member was working at the soiled end in the pooled water.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
35
|
|
Site:
Galley-Deck 16 - World Market Scullery
|
|
Violation:
The starboard flight-type warewashing machine spewed water from the soiled end, causing water to accumulate on the deck in front. Crew placed buckets underneath the soiled side of the machine to collect the gray water that was discharging. The left bucket was overflowing with water, which pooled on the deck in front of the soiled end. Crew used mops to direct the gray water into the scupper. A crew member was working at the soiled end in the pooled water.
|
|
Recommendation:
Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 16 - World Market Scullery
|
|
Violation:
The deck tile grout at the soiled landing for the starboard conveyor-type warewashing machine was missing, and water collected in areas of recess.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 16 - World Market Scullery
|
|
Violation:
The wash solution inside the portside conveyor-type warewash machine was soiled with brown granular accumulation. Crew initiated corrective action.
|
|
Recommendation:
Ensure warewashing machines, drainboards, and the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw food, or laundering wiping cloths are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination and accumulation of debris and to ensure the equipment performs its intended function; (3) At least every 24 hours (if used).
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 15 - World Market Production
|
|
Violation:
The plastic lid for a container of cut lettuce was cracked, creating a difficult-to-clean surface. Crew initiated corrective action.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance. Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact and tight and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
22
|
|
Site:
Pantry-16 - Mix Bar
|
|
Violation:
The glasswash machine was identified as out of order since 27 August 2026.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
08
|
|
Site:
Pantry-16 - Mix Bar
|
|
Violation:
The tube attached to the carbonator's backflow prevention device intermediate vent was not positioned to allow the device to drain. Crew initiated corrective action.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
13
|
|
Site:
Pantry-16 - Mix Bar Walk-In Refrigeration Unit # 16301
|
|
Violation:
A crew member was servicing a light inside walk-in refrigeration unit # 16301 directly above a mobile trolley of food. The crew member did not move the trolley prior to conducting work. Crew initiated corrective action.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP, on request during inspections, knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Control Point principles, and food safety standards. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these standards; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the supervisor or person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of TCS/PHF and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of TCS/PHF, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of TCS/PHF; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control points in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with these standards.
|
|
|
Item No.:
19
|
|
Site:
Pantry-16 - Mix Bar Walk-In Refrigeration Unit # 16301
|
|
Violation:
A mobile trolley of food wa below a crew member servicing a deckhead light inside walk-in refrigeration unit #16301.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; (6) At least 150 millimeters (6 inches) above the deck on shelving units.
|
|
|
Item No.:
17
|
|
Site:
Room Service-Deck 11 - Beverage Station
|
|
Violation:
The posted time control plan identified coffee machine's dispenser as a unit on time control, but crew identified these units are no longer in use. Crew removed this piece of equipment from the time control plan.
|
|
Recommendation:
Maintain a written time control plan that ensures compliance with these standards on the vessel and make it available for review during inspections. Ensure a time control plan is posted and available to all crew working at each outlet where time control is used. Ensure plan(s): (1) Include set-up and discard times for each outlet. Include all services and events where TCS/PHF is kept on time control. If used, ensure colored labels correspond to the discard times stated in the plan; (2) List all units (to include refrigeration and hot holding units, preparation counters, cabinets, compartments, and equipment) on time control. Cabinets and compartments on time control must be physically labeled; (3) Describe or show the flow of TCS/PHF from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
33
|
|
Site:
Room Service-Deck 11 - Beverage Station
|
|
Violation:
The deck tile grout at the clean landing for the conveyor-type warewashing machine was missing, causing water to collect in areas of recess.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
17
|
|
Site:
Galley-Deck 7 - Crown Grill Show Galley
|
|
Violation:
The posted time control plan identified a chaffing dish on the counter as a unit on time control, but the piece of equipment was not physically labeled as being on 'time control.' Crew initiated corrective action.
|
|
Recommendation:
Maintain a written time control plan that ensures compliance with these standards on the vessel and make it available for review during inspections. Ensure a time control plan is posted and available to all crew working at each outlet where time control is used. Ensure plan(s): (1) Include set-up and discard times for each outlet. Include all services and events where TCS/PHF is kept on time control. If used, ensure colored labels correspond to the discard times stated in the plan; (2) List all units (to include refrigeration and hot holding units, preparation counters, cabinets, compartments, and equipment) on time control. Cabinets and compartments on time control must be physically labeled; (3) Describe or show the flow of TCS/PHF from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
17
|
|
Site:
Galley-Deck 7 - Gigi's Pizzeria
|
|
Violation:
Crew placed a 4-hour discard sticker on the exterior of a metal container inside the soup kettle. This unit was not listed on the posted time control plan as a unit on time control. Crew informed the inspector that this unit was on temperature control.
|
|
Recommendation:
Maintain a written time control plan that ensures compliance with these standards on the vessel and make it available for review during inspections. Ensure a time control plan is posted and available to all crew working at each outlet where time control is used. Ensure plan(s): (1) Include set-up and discard times for each outlet. Include all services and events where TCS/PHF is kept on time control. If used, ensure colored labels correspond to the discard times stated in the plan; (2) List all units (to include refrigeration and hot holding units, preparation counters, cabinets, compartments, and equipment) on time control. Cabinets and compartments on time control must be physically labeled; (3) Describe or show the flow of TCS/PHF from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
39
|
|
Site:
Food Service General-Integrated Pest Management
|
|
Violation:
Pests were present in the following food-service areas:
Deck 16 ? World Market Buffet Middle Bread Station: One small fly was on the deckhead above the bread buffet island.
Deck 16 ? World Market Buffet Forward Pasta Station: One small fly was on the deckhead above the buffet island.
Deck 16 ? World Market Buffet Middle Beverage Station: One small fly was on the clean storage rack.
Deck 7 ? Princess Live Bar: Two small flies were on the bulkhead by the televisions of the crew service area.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
|
|
|
Item No.:
21
|
|
Site:
Food Service General-Condition of the Countertops
|
|
Violation:
The marble countertops were chipped and cracked creating difficult-to-clean surfaces in the following areas:
-
Deck 16 - World Market Starboard Pasta Station
-
Deck 16 ? World Market Portside Pasta Station
-
Deck 16 ? World Market Buffet Portside Hot International Station
Crew stated the identified areas have already been documented in their records as part of the corrective actions being tracked under ongoing deck correction plans.
|
|
Recommendation:
Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Maintain nonfood-contact equipment in good repair and proper adjustment including: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact and tight and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 5 - Hot Galley
|
|
Violation:
The stainless-steel bulkhead behind the tilting pan had an accumulation of condensate. This was immediately corrected.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|