|
|
|
Item No.:
39
|
|
Site:
Dining Room-Deck 4 - Team Dining #1
|
|
Violation:
Two fruit flies were flying around the back buffet line. This was corrected immediately.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-Deck 7 - Poultry
|
|
Violation:
Water dripped from the deckhead and pooled on the deck below the evaporator condensing unit in walk-in refrigeration unit #G-702. This was corrected immediately.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
27
|
|
Site:
Preparation Room-Deck 7 - Meat
|
|
Violation:
Water pooled in the undercounter technical space of unit #G-710. This was corrected immediately.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-Deck 7
|
|
Violation:
Half an inch of water pooled in the deckhead light fixture cover next to the proofing cabinet. This was corrected immediately.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
36
|
|
Site:
Preparation Room-Deck 7
|
|
Violation:
The light intensity measured less than 220 lux in front of the rotating oven. This was corrected immediately.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux on food preparation surfaces.
Ensure the light intensity is at least 220 lux as measured 750 millimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 7 - Pot Wash
|
|
Violation:
The upper left spray arm nozzle was blocked with brown food residue. This was corrected immediately.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
19
|
|
Site:
Bar-Deck 9 - Keys on the Water
|
|
Violation:
Two, five-inch openings were below the television alcove above closed bottles of liquor making the space difficult to clean. This was corrected immediately.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; (4) At least 150 millimeters (6 inches) above the deck; (5) At least 127 millimeters (5 inches) for food in packages and working containers on pallets, skids, and racks; (6) At least 150 millimeters (6 inches) above the deck on shelving units.
|
|
|
Item No.:
21
|
|
Site:
Bar-Deck 9 - Key on the Water
|
|
Violation:
Two, five-inch openings were below the television alcove above closed bottles of liquor making the space difficult to clean. This was corrected immediately.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Deck 10 - Mexican Cantina
|
|
Violation:
The deck coving was not flush at the buffet line.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure surfaces subject to routine splashes, spillage, or other soiling during normal use have easily cleanable features.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Deck 10 - Mexican Cantina
|
|
Violation:
Water continuously dripped from the deckhead light fixture next to the fire sprinkler and pooled on the deck.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
34
|
|
Site:
Buffet-Deck 10 - Mexican Cantina
|
|
Violation:
Water continuously dripped from the deckhead light next to the fire sprinkler and pooled on the deck. Crew stated this was due to a brine line above being repaired.
|
|
Recommendation:
Ensure the plumbing system in food areas is in good repair.
|
|
|
Item No.:
01
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Reporting
|
|
Violation:
Since 31 July 2026, 24-hour reports for 16 of 18 voyages were submitted outside of the required range. AGE reports were submitted less than 24 hours prior to arrival for the following voyages: 26081, 260824, MVAP20260911, MVAP20260918, and MVAP20260921. AGE reports were submitted more than 36 hours prior to arrival for the following voyages: 260727, 260731, 260803, 260814, 260817, 260821, 260828,260903, MVAP20260907, and MVAP20260914.
Staff stated the correct reporting time frames when asked by the inspector.
|
|
Recommendation:
Ensure the master, medical staff, or other designated staff of a vessel destined for a U.S. port from an international port submits at least one standardized AGE report based on the number of reportable AGE cases in the AGE surveillance log to VSP no less than 24-hours?but not more than 36 hours?before the vessel?s expected arrival at the U.S. port.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Collection Containers
|
|
Violation:
The vessel's modified stool specimen collection vials expired on 31 July 2026. The box was discarded and crew stated during the closing meeting that another box was available.
|
|
Recommendation:
Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each), as well as a shipping container that meets the latest shipping requirements of the International Air Transport Association (IATA) and U.S. Department of Transportation for Biological Substances, Category B designated shipments (or higher). Ensure the vessel maintains the appropriate labels and markings required for shipping Biological Substances, Category B shipments. Ensure the vessel maintains appropriate refrigerant materials to keep clinical specimens cool. For guidance, refer to Annex 13.3.5.
|
|
|
Item No.:
01
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Reporting
|
|
Violation:
The 24-hour AGE reports submitted prior to arrival in West Palm Beach documented incorrect counts of passengers and crew on the following voyages:
(1) 14-18 September 2026: The 24-hour AGE report documented 1,106 passengers; however, 1,108 passengers were on the manifest at the beginning of the voyage.
(2) 18-21 September 2026: The 24-hour AGE report documented 521 crew: however, 523 crew were on the manifest at the beginning of the voyage..
|
|
Recommendation:
Ensure the AGE report contains the following: (1) Name of the vessel; (2) Port of embarkation; (3) Date of embarkation; (4) Port of disembarkation; (5) Date of disembarkation; (6) Total number of reportable AGE cases among passengers, including those who have disembarked because of illness?even if the number is 0 (zero reporting); (7) Total number of reportable AGE cases among crew members, including those who have disembarked because of illness?even if the number is 0 (zero reporting); and (8) Total number of passengers and crew members on the cruise.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Portside Aft Bunker Station
|
|
Violation:
The chain was not attached to the far-left potable water filling line screw cap and was corroded.
|
|
Recommendation:
Ensure the potable water filling line has a screw cap fastened by a noncorroding cable or chain to an adjacent bulkhead or surface in such a manner that the cap cannot touch the deck when hanging free. Ensure the hose connections are unique and fit only the potable water hoses.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Disinfection
|
|
Violation:
A shower hose disinfected at 50 ppm on 10 June 2026 from 1349 to 1603 was not disinfected for a total of four hours per the disinfection records.
|
|
Recommendation:
Disinfect the potable water system after potential contamination by increasing the free halogen residual to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Pipe Striping
|
|
Violation:
The potable water line after the aft and forward bunker lines joined was striped blue/gray/blue for distillate/permeate water heading to the potable water system. Prior to the juncture, the lines were striped blue/green/blue. Additionally, the potable water line was striped blue/gray/blue after the reverse osmosis' distillate water was chlorinated.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate water lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations.
Stripe or paint these lines, including potable water supply lines in technical lockers, at 5-meters (16.4 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Disinfection
|
|
Violation:
The tank records did not indicate the potable water tank surfaces remained wet with 200 ppm of chlorine for at least two hours. The disinfection time was recorded as 1300 to 1430 for potable water tank 4 port taken out of service on 13 April 2026 and potable water tank 4 starboard taken out of service 7 May 2026.
|
|
Recommendation:
Ensure the empty tank cleaning and disinfection procedure for potable water tanks is only used for routine cleaning and disinfection. It is not approved for known or suspected contaminated tanks. Ensure the following steps are followed: (1) Remove (strip) all water from the tank; (2) Clean all tank surfaces, including filling lines, with an appropriate detergent; (3) Rinse all surfaces of the tank thoroughly with potable water; (4) Remove (strip) the rinse water from the tank; (5) Wet all surfaces of the tank with at least a 200 mg/L (ppm) solution of chlorine (this can be done using new, clean mops, rollers, sprayers, etc.). Ensure the tank surfaces remain wet with the chlorine solution for at least 2 hours. Check, monitor, and document the disinfection concentration and contact time; (6) Refill the tank and verify the free halogen residual is less than or equal to 5.0 mg/L (ppm) before placing the tank back into service. Document the free halogen residual level.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Deck 10 Starboard Whirlpool
|
|
Violation:
The water temperature measured 111.4°F in the tub.
|
|
Recommendation:
Provide a temperature-control mechanism to prevent the temperature from exceeding 40°C (104°F) on whirlpool spas and spa pools. Measure the water temperature within the whirlpool spa or spa pool tub itself.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Deck 10 Starboard Whirlpool
|
|
Violation:
The halogen analyzer reading was more than 0.2 ppm from the manual comparison test. The analyzer recorded the chlorine level as 4.55 ppm; however, manual samples measured 3.55 ppm and 3.32 ppm by the crew and 4.20 ppm and 3.82 ppm by the inspector.
|
|
Recommendation:
Maintain and operate the halogen and pH analyzer-chart recorder in accordance with the manufacturer?s instructions. Conduct a manual comparison test before opening the RWF to verify calibration for free halogen residual and pH. Ensure the analyzer reading is within 0.2 mg/L (ppm) for free halogen and 0.2 for pH. For RWFs open longer than 24 hours, conduct a manual comparison test every 24 hours.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Deck 10 Pools
|
|
Violation:
The bather load calculation provided to the inspector for the forward/central pool was based on a 66 gallon per minute flow rate and stated the bather load was 14 persons; however, the calculation was 13.2 persons. The actual flow rate during the inspection was 100 gallons per minute.
Additionally, the aft pool sign stated the bather load was 19 persons; however, the maximum bather load based on the flow rate at the time of inspection was 16 persons.
|
|
Recommendation:
Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per 19 liters (5 gallons) per minute of recirculation flow. Use flow rates from flow meters to calculate bather loads. Provide safety signs for all RWFs. Ensure signs are in a prominent and unobstructed location for all users of the RWF. At a minimum, include the following words: (1) Do not use these facilities if you are experiencing diarrhea, vomiting, or fever. (2) No children in diapers or who are not toilet trained; (3) Shower before entering the facility; (4) Bather load #. For children?s RWF safety signs, include the exact wording ?TAKE CHILDREN ON FREQUENT BATHROOM BREAKS? or ?TAKE CHILDREN ON FREQUENT TOILET BREAKS.?
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Reporting
|
|
Violation:
Two 24-hour reports were submitted for voyage 260824 when only one 24-hour report was needed per the ship?s itinerary.
|
|
Recommendation:
Submit routine 24-hour and 4-hour update reports electronically and ensure the vessel maintains proof onboard that the report was successfully received by VSP. Do not submit duplicate reports or reports when not required.
|
|