|
|
|
Item No.:
27
|
|
Site:
Buffet-Deck 9 Pizzeria
|
|
Violation:
The horizontal sneeze guard above the pizza preparation countertop was soiled with more than a day's accumulation of dust. The area was not in operation and had been previously cleaned and sanitized.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 9 Waves Grill Pantry
|
|
Violation:
The microwave oven, which was not easily movable, was elevated less than 100-millimeters (4-inches) above the countertop.
|
|
Recommendation:
Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 9 Terrace Cafe Warewash
|
|
Violation:
The painted deck was chipped and in disrepair in front of the hood-type warewash machine.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 9 Terrace Cafe
|
|
Violation:
The painted deck was chipped and in disrepair throughout the galley.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 10 Polo/Toscana
|
|
Violation:
The top of the knife locker was soiled with more than a day's accumulation of dust.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
38
|
|
Site:
Galley-Deck 4 Chemical Locker Room
|
|
Violation:
Two wash, rinse, and sanitizing buckets were stored upright, wet nested inside a wet mop bucket.
|
|
Recommendation:
Ensure wash, rinse, and sanitize buckets or other containers stored with maintenance tools are inverted and nested.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 4
|
|
Violation:
The painted deck was in disrepair with the paint bubbling and cracking throughout the area.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Deck 4 Grand
|
|
Violation:
The light intensity measured less than 50 lux at the four waiter stations directly outside the inner circular seating area with the chandelier. Staff stated the lights were on cleaning mode.
|
|
Recommendation:
In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
27
|
|
Site:
Bar-Deck 5 Martinis
|
|
Violation:
The back bar bottle storage shelves were soiled with more than a day's accumulation of dust. The area was not in operation and had been previously cleaned and sanitized.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
19
|
|
Site:
Bar-Deck 5 Martinis
|
|
Violation:
Opened alcohol bottles were stored on soiled back bar shelves with more than a day's accumulation of dust.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Deck 9 Thalasso
|
|
Violation:
A safety sign was not at either entrance to the whirlpool spa. None of the four small signs on the side wall next to the facility cautioned against children in diapers or those who are not toilet trained from using the facility, and stated ?you must be at least 18 years of age to use the whirlpool.? A larger safety sign was located on the back side wall between the stairs along the walkway. This sign contradicted the small signs by warning ?children under the age of 16 are not permitted to use the pool and whirlpool without adult supervision.'
|
|
Recommendation:
In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure. Those under 16 years of age are considered children for the purpose of whirlpool safety sign requirements.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Deck 9 Port and Starboard Whirlpool Spas
|
|
Violation:
The safety signs were located on the back side of the whirlpool spas, and not at either stair entrances.
|
|
Recommendation:
In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure. Those under 16 years of age are considered children for the purpose of whirlpool safety sign requirements.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP did not include required hypochlorous acid (HOCl) disinfectant concentration and pH level during outbreak responses. Additionally, the electronic link 'Hypochlorous Acid Monitoring Log' indicated to test the pH and chlorine three times daily, whereas the printed Guidelines for EcoloxTech HOCL Generator document stated to test the pH and chlorine twice each day.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Deck 2 Pulper Room
|
|
Violation:
The hot and cold water lines were not striped to indicate potable water before the reduced pressure backflow prevention device to the economizer (pulper). This was corrected before the end of the inspection.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
|
|
|
Item No.:
29
|
|
Site:
Pantry-6 Room 6c017
|
|
Violation:
The water temperature at the handwashing station measured 127°F. The user could not adjust the temperature.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|
|
Item No.:
02
|
|
Site:
Medical-
|
|
Violation:
A guest vomited on the carpet in his cabin on 24 September at 11:30 am per housekeeping records. During the inspection, medical staff stated they attempted to follow-up with the passenger, however did not document the phone call and the guest's refusal for medical evaluation. Records indicated the guest was also not available on 25 September, which was a disembarkation day.
|
|
Recommendation:
Ensure a reportable case of AGE is a case reported to the master of the vessel, the medical staff, or other designated staff by a passenger or a crew member and meets the case definition based on the following symptoms: (1) Diarrhea (three or more episodes of loose stools in a 24 hour period or what is above normal for the individual. See section 4.1.2.1.3, illness symptoms); or (2) vomiting and one additional symptom including one or more episodes of loose stools in a 24-hour period, or abdominal cramps, or headache, or muscle aches, or fever (temperature of greater than or equal to 38°C [100.4°F]). Ensure medical records document evaluations for public vomit/diarrhea incidents when the individuals involved are identified. Proper evaluation should include determining if the individuals meet the definition of an AGE reportable case and assessing the need for isolation.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 9 Waves Grill Pantry
|
|
Violation:
The countertop below the microwave oven was soiled with more than a day's accumulation of food debris. The area was in operation.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|